843 resultados para Determinação minoxidil


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sulfasalazine is a prodrug used in the treatment of the Chron's disease and rheumatoid arthritis. Two analytical methods for analysis of sulfasalazine in oral suspension were validated using Spectrophotometric and HPLC. There is not any pharmacopoeic method to assay sulfasalazine in oral suspension. The methods are insurance and fast execution for the quality control. Both, suspension and tablets 500 mg (Azulfin®) had been analyzed by methods using UV/VIS and HPLC and the results were satisfactory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a quality assurance and quality control protocol in order to ensure the reliability of analytical results for the determination of acid volatile sulfides in environmental samples by potentiometry. The monitoring of the ion selective sensor readings must be realized continually and particularly in this situation where the analyte is susceptible to transformation and volatilization. Potentiometry with the standard addition was presented as a rapid, accurate, precise, feasible as well as a low cost technique. Concentrations of the analyte in the range of 0.49 to 1.02 mg L-1 were tested with percentage recoveries varying from 89 to 113%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, fast and inexpensive method was developed to determine essential elements in pellets of rice samples using energy dispersive X-ray fluorescence spectrometry (EDXRF). The accuracy and precision were evaluated using Standard Reference Material (rice flour NIST 1568a), and yielding relative standard deviation below 5%. The paired t-test showed good agreement within 95% confidence values. The detection limits (3σ) of Mn and Zn were 5.1 and 2.2 mg kg-1, respectively. The proposed method proved to be effective when used to determine Mn and Zn in commercial samples of rice without go by stage of decomposition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and fast method for determination of 40 basic drugs in human plasma employing gas-chromatography with nitrogen-phosphorus detection was developed and validated. Drugs were extracted from 800 µL of plasma with 250 µL of butyl acetate at basic pH. Aliquots of the organic extract were directly injected on a column with methylsilicone stationary phase. Total chromatographic run time was 25 min. All compounds were detected in concentrations ranging from therapeutic to toxic levels, with intermediate precision CV% below 11.2 and accuracy in the range of 92-114%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work consists of the development and validation of analytical method for evaluation of glycyrrhizic acid, salicylic acid, and caffeine in chitosan-alginate nanoparticles by high performance liquid chromatography. Method validation investigated parameters such as linearity, precision, accuracy, robustness and specificity, which gave results within the acceptable range. The methods were applied to nanoparticles suspensions containing the drugs and were able to determine the entrapment efficiency successfully. The best entrapment efficiency was achieved with the glycyrrhizic acid (95.4%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The QuEChERS extraction method followed by quantification using HPLC/UV-FL was evaluated for deoxynivalenol (DON) and zearalenone (ZEA) determination in natural and parboiled rice and their fractions (bran and husk). The comparison between QuEChERS and partition with acetonitrile extraction showed that the first one was better. It presented higher recovery (91% for DON, 105% for ZEA) wih precision ranging from 1.5 to 18.6%. The limits of quantification were 22.2 µg kg-1 for DON and 4.3 µg kg-1 for ZEA. DON and ZEA showed higher levels in endosperm of parboiled rice (8 e 111.7 µg kg-1, respectively) when compared to natural rice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performance of inductively-coupled plasma optical emission spectrometers with axial and radial views for determination of iodine in table salt was evaluated. Interference and memory effects in nitric acid and water-soluble tertiary amines (CFA-C) media were studied. Based on a factorial experiment, one optimum instrument operational condition for axial configuration, and two optima conditions for radial configuration was established. The ICP OES with axial view was 5-fold more sensitive than the radial view. Both matrix matching and standard addition methods were used for iodine quantification and for most samples, both strategies of calibration led to similar results. Recoveries ranged from 104 to 114%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Catalyst based on Kegging-type heteropolyacids (H3PW12O40 - HPA), supported on SiO2 (H3PW), were prepared by the impregnation method under different thermal treatment conditions. The materials were characterized by different instrumental techniques and used as catalysts in the methyl esterification reactions of stearic acid. Using the catalyst with 15% of HPA, conversions higher than 60% were obtained after 2 h of reaction at 65 ºC. Recovery studies using hot-filtration with ethanol at 75 ºC showed satisfactory activity for two additional reaction cycles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study utilized thermogravimetry (TG) and optical emission spectrometry with inductively coupled plasma (ICP/OES) to determine the amount of calcium in calcium lactate tablets used in the treatment of osteoporosis. Thermogravimetry results indicated that the decomposition temperature of CaCO3 occurred at 603.9 and 609.4 ºC in the samples of calcium lactate and tablets, respectively. The calcium content obtained by TG for the tablets sample showed a similar result to that disclosed by ICP-OES, indicating a value of 8.93% for both techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article discusses the adsorption kinetics of a L-cysteine monolayer onto a gold surface by means of information obtained through the QCM technique. The results indicate that the adsorption process is rapid and follows the Langmuir isotherm, in which adsorption and desorption are considered. From these measurements the following parameter values were obtained: k d = (4.2 ± 0.4) x 10-3 s-1, k a = 75 ± 6 M-1 s-1, Keq=(1.8 ± 0.3) x 10(4) M-1 and ΔGads = - (5.8 ± 0.2) kcal mol-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the levels of plasticizer endocrine disruptors (diethyl phthalate, dibutyl phthalate, and bisphenol A) in drinking water at Paraíba do Sul River region and release of these compounds from bottled water. An analytical method employing solid phase extraction and GC/MS was optimized and validated. The results showed that the method is selective, linear (r² > 0.99), precise (RSD <12%), accurate (recoveries between 62 and 105%), sensitive and robust. Applying the method, the presence of all studied pollutants in drinking water was observed for the three sampled plasticizers. These plasticizers were not found in mineral bottled water, before or after storage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple flow system with multiple pulse amperometric detection using a single working electrode is proposed for simultaneous determination of ascorbic (AA) and acetylsalicylic (AAS) acids in pharmaceutical formulations. The procedure is based on application of two potential pulses: 0.90 V/50 ms: oxidation and determination of AA without the interference of AAS; 1.35 V/50 ms: oxidation of both compounds and quantification of AAS by current subtraction using a correction factor. Sampling rate was estimated as 125 injections per hour and the limits of detection were 0.17 and 0.16 µmol L-1 for AA and AAS, respectively. Results for commercial samples agreed with those obtained using HPLC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A high performance liquid chromatographic-diode array detection method for the determination of busulfan in plasma was developed and validated. Sample preparation consisted of protein precipitation followed by derivatization with sodium diethyldithiocarbamate and liquid-liquid extraction with methyl-tert-butyl ether. Chromatograms were monitored at 277 nm. Separation was carried out on a Lichrospher RP 18 column (5 µm, 250 x 4 mm). The mobile phase consisted of water and acetonitrile (20:80, v/v). The method presented adequate specificity, linearity, precision and accuracy and allowed reliable determination of busulfan in clinical plasma samples, being applied to three patients submitted to bone marrow transplantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

UDP-N-acetylglucosamine-enolpyruvyl transferase (MurA) catalyzes the reaction between phosphoenol pyruvate and UDP-N-acetylglucosamine. We present a theoretical approach using the semiempirical PM6 method for defining protonation state of three active site residues, K22, H125, and K160. Prior comparison with neutron diffraction data showed that PM6 accurately predicted protonation states of active site residues of b-trypsin and D-xylose isomerase. Using the same methodology with MurA crystallographic data, we conclude that when reaction intermediate is located at the active site, H125 and K22 are in protonated form and K160 in neutral form.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although metals and nitrogen/sulfur compounds have been the main concern of the petroleum industry, issues concerning the harmful effects on catalysts poisoning and product contamination by other contaminants such as oxygen-containing compounds have been raised. Trace amounts of carbonyl and carboxyl compounds in petroleum products can lead to catalyst poisoning. Additionally, oxygenates may be present in final polyethylene and polypropylene resins, affecting the quality of food packaging. In this work, we reviewed potential analytical approaches for oxygenates determination in petroleum products and report the features of each potential technique.