833 resultados para determinação de amônia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a closed-vessel microwave-assisted acid decomposition procedure for clays was developed. Aluminum, Ca, Fe, K, Mg, Na, Si, and Ti were determined in clay digestates by inductively coupled plasma optical emission spectrometry. The most critical parameter for total decomposition of clays was the composition of the reagent mixture. The applied power and the heating time exerted a less critical influence. Best decomposition conditions were attained using a reagent mixture containing 4 mL aqua regia plus 3 mL HF and the heating program was implemented in 12 min. The accuracy of the results was demonstrated using two standard reference materials and a paired t-test showed a good agreement between determined and certified values at a 95% confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents an alternative method for determination of the herbicides tebuthiuron and hexazinone in ground water. The extraction was made with dichloromethane and the analyses by high performance liquid chromatography (HPLC), using reversed-phase column, C-18, mobile phase methanol/water 50:50, v/v, detection and quantification at 247 nm. The following validation parameters were obtained: limit of detection of method 0.02 and 0.03 µg L-1, limit of quantification of method 0.07 and 0.09 µg L-1; linear range limit of quantification of instrument - 300 µg L-1 (r² > 0.998); recoveries from 90.3 to 108.2% and 90.3 to 101.6%; intermediary precision (%RSD) < 8 and < 6%, for hexazinone and tebuthiuron, respectively. The method showed to be efficient and reliable for determination of the herbicides in ground water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Automatic flow procedures based on the multicommutation concept, dedicated to the determination of 3-hydroxybutyrate, glucose and cholesterol are proposed. The enzymes were immobilized on glass beads and packed into mini-columns that were coupled to a flow system. Sampling throughputs of 55, 40 and 40 determinations per hour, linear response from 10 to 150, 50 to 600, 25 to 125 mg L-1, detection limits of 1.5, 14 and 4 mg L-1 and relative standard deviations of 1, 2 and 2% for 3-hydroxybutyrate, glucose and cholesterol, respectively, were achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes a simple, fast and inexpensive method to determine As in natural waters, using X-ray fluorescence. 50 µL of each sample containing 100 mg L-1 of yttrium as internal standard were deposited over a 2.5 µm thickness MylarTM film. The samples were dried at 50 &deg;C for 2 h. X-ray spectra were obtained using an EDXRF apparatus. The accuracy was determined by analyte addition/recovery and by comparison with Hydride Generation Atomic Absorption Spectrometry (HG AAS). A recovery of about 100% was obtained and the results were in good agreement with HG AAS. The method showed a relative standard deviation of 6.8% and a detection limit of 10.5 µg L-1 of As.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coffee is a product consumed all around the world, Brazil being the biggest exporter. However, little is known about the difference in composition of the different brands in terms of bioactive substances. In the present study, ten of the most consumed brands of coffee in Rio de Janeiro were analyzed. Caffeine contents, trigonelline and total chlorogenic acid varied from 0.8 g/100g to 1.4 g/100g; 0.2 g/100g to 0.5 g/100g and from 3.5 g kg-1 to 15.9 g kg-1, respectively. The large heterogeneity observed in the amounts of the bioactive compounds can be attributed to different formulations of the various brands, as well as to different roasting conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The results suggest that the two variables studied are significant and that they may be independently optimized. The material of the sample holder interferes with the incineration process only due to the amount of heat transfered. The sample holder volume aids diffusion of the atmosphere to the honey sample, minimizing the foaming effect. According to the results, for the thermogravimetric analysis of ash content in honey, sample holders of platinum or alumina of 150 µL are indicated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

KBrO3 is registered by the FAO/OMS as a genotoxic and carcinogenic compound. In spite of this, KBrO3 is still employed by Brazilian bakeries. Nowadays ion exchange chromatography (IEC) is the most rapid and trustful method for BrO3- analysis. When at high concentrations, chloride ions can interfere in the BrO3- analysis, if the detection is performed by electrical conductivity. On the other hand, spectrophotometric detection, presented here is based on the absorption of BrO3- in the ultraviolet region (210 - 230 nm) where the absortion of chloride ions is very low, thus making possible the qualitative and quantitative analysis of BrO3- in flour improver samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple flow injection procedure was developed for determining dipyrone (1-phenyl-2,3-dimethyl-4-methylaminomethano-5-pyrazolone sodium, metamizol, analgin) in pharmaceutical formulations. The determination is based on the reduction of Ag+ ions to Ag0 by dipyrone. A colloidal suspension of Ag0 produced was transported by carrier solution (0.01 mol L-1 NaOH) and turbidimetrically detected at 425 nm. The analytical curve for dipyrone was linear in the range from 5.0 x 10-4 to 2.5 x 10-3 mol L-1 with a correlation coefficient of 0.9990. The detection limit was 1.3 x 10-4 mol L-1 (3sigmaB/slope). The relative standard deviation for ten successive measurements was 1.8% and an analytical frequency of 45 h-1 was obtained. The recovery values from three samples ranged from 96.0 to 102%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An indirect flow injection spectrophotometric procedure is proposed for the determination of N-acetyl-L-cysteine in pharmaceutical formulations. In this system, ferroin ([Fe(II)-(fen)2]2+) in excess, with a strong absorption at 500 nm, is oxidized by cerium(IV) yielding cerium(III) and [Fe(III)-(fen)2]3+ (colorless), thus producing a baseline. When N-acetyl-L-cysteine solution is introduced into the flow injection system, it reacts with cerium(IV) increasing the analytical signal in proportion to the drug concentration. Under optimal experimental conditions, the linearity of the analytical curve for N-acetyl-L-cysteine ranged from 6.5x10-6 to 1.3x10-4 mol L-1. The detection limit was 5.0x10-6 mol L-1and recoveries between 98.0 and 106% were obtained. The sampling frequency was 60 determinations per hour and the RSD was smaller than 1.4% for 2.2x10-5 mol L-1 N-acetyl-L-cysteine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the last decade, the combined use of chemometrics and molecular spectroscopic techniques has become a new alternative for direct drug determination, without the need of physical separation. Among the new methodologies developed, the application of PARAFAC in the decomposition of spectrofluorimetric data should be highlighted. The first objective of this article is to describe the theoretical basis of PARAFAC. For this purpose, a discussion about the order of chemometric methods used in multivariate calibration and the development of multi-dimensional methods is presented first. The other objective of this article is to divulge for the Brazilian chemical community the potential of the combination PARAFAC/spectrofluorimetry for the determination of drugs in complex biological matrices. For this purpose, two applications aiming at determining, respectively, doxorrubicine and salicylate in human plasma are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A boron-doped diamond electrode is used for determination of Mn(II) in atmospheric particulate matter by square wave cathodic stripping voltammetry. The analytical curve was linear for Mn(II) concentrations between 5.0 and 37.5 µg L-1, with quantification limit of 3.6 µg L-1. The precision was evaluated by the relative standard deviation, with values between 5.1% and 9.3%. The electrode is free of adsorption, minimizing memory effects. Samples collected in the workplace atmosphere of a foundry had Mn(II) concentrations between 0.4 and 4 µg m-3. No significant differences were observed between the proposed method and inductively coupled plasma optical emission spectroscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review reports the determination of absolute configuration of primary and secondary alcohols by ¹H NMR spectroscopy, using the Mosher method. This method consists in the derivatization of an alcohol possessig unknown absolute configuration with one or both enantiomers of an auxiliary reagent. The resulting diastereoisomer spectra are registered and compared, and the chemical shift differences (DdR,S = deltaR - deltaS) are measured. The determination of the absolute configuration of the alcohol molecule is based on the correlation between its chiral center and the auxiliary reagent's chiral center. Therefore, the determination of the absolute configuration depends on aromatic ring shielding effects on the substituents of the alcohol as evidenced by the ¹H NMR spectrum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several extraction procedures are described for the determination of exchangeable and fixed ammonium, nitrate + nitrite, total exchangeable nitrogen and total nitrogen in certified reference soils and petroleum reservoir rock samples by steam distillation and indophenol method. After improvement of the original distillation system, an increase in worker safety, a reduction in time consumption, a decrease of 73% in blank value and an analysis without ammonia loss, which could possibly occur, were achieved. The precision (RSD < 8%, n = 3) and the detection limit (9 mg kg-1 NH4+-N) are better than those of published procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the begining of April 2004, concentrations of NHx (NH3 + NH4+) were measured in surface waters of the Guanabara Bay. Concentrations varied from 2 to 143 mmol L-1. Ammonia exchange at the air-sea interface was quantified using a numerical model. No measurement of NH3 concentration in air (c air) was performed. Thus, calculations of NH3 flux were based on the assumptions of c air = 1 and 5 µg m-3. Fluxes were predominantly from the water to the atmosphere and varied from -20 to almost 3500 µg N m-2 h-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work is to discuss selected applications of electroanalytical techniques for the detection of pesticides in foods and beverages, published in the last ten years. The applications involved different working electrodes for the electroanalytical determination of pesticides, namely amperometric biosensors, cholinesterase-based biosensors, polymer-modified electrodes, ultramicroelectrodes and hanging mercury drop electrodes. They were used for several voltammetric and amperometric techniques in different analytical procedures for the detection and quantification of different classes of pesticides in different food matrices.