575 resultados para Validação de Teste
Resumo:
The aim of this work was to develop and validate an analytical methodology for determination of artemisinin used as antimalaric. The method was based on high performace liquid chromatography, using a CN column with mobile phase composed of methanol : H2O 50:50 (V/V). The results showed that the method presented linearity from 50 to 1500 µg/mL. It was considered selective, accurate, precise according to the specific resolution from ANVISA, the Brazilian regulatory agency.
Resumo:
The aim of this work was to evaluate antioxidant activity of lemon seeds added to soybean oil, submitted to accelerated incubator-storage test and to determine its synergistic effect with the synthetic antioxidant TBHQ. The treatments Control, TBHQ (50 mg/kg), LSE (2,400 mg/kg Lemon Seed Extract), Mixture 1 (LSE + 50 mg/kg TBHQ) and Mixture 2 (LSE + 25 mg/kg TBHQ) were prepared and subjected to the accelerated incubator-storage test at 60 ºC for 12 days; samples were taken every 3 days and analyzed regarding peroxide value and conjugated dienes. The results showed that antioxidant activity of the tested treatments were: TBHQ = Mixture 1 = Mixture 2 > LSE > Control.
Resumo:
Chromatographic methods are commonly used for analysis of small molecules in different biological matrices. An important step to be considered upon a bioanalytical method's development is the capacity to yield reliable and reproducible results. This review discusses validation procedures adopted by different governmental agencies, such as Food and Drug Administration (USA), European Union (EU) and Agência Nacional de Vigilância Sanitária (BR) for quantification of small molecules by bioanalytical chromatographic methods. The main parameters addressed in this review are: selectivity, linearity, precision, accuracy, quantification and detection limits, recovery, dilution integrity, stability and robustness. Also, the acceptance criterions are clearly specified.
Resumo:
The use of antioxidants either to prevent or retard food's lipids oxidation was approved after inquires that verified their security within a daily intake limit. In this study, the methodology was developed and validated for the analysis of synthetic antioxidants: propylgallate (PG), tert-butylhydroquinone (TBHQ), butylhydroxyanisole (BHA), octylgallate (OG) and butylhydroxytoluene (BHT) in vegetables oils, margarine and hydrogenated fats by high performance liquid chromatographic. The methodology revealed itself efficient, with recovery rates above 90% for all antioxidant substances, besides good linearity in concentration range of 40-240 mg kg-1 (r = 0,999), repeatability with CV < 3,7% and limit of quantification 16.55, 10.32, 1.40, 3.76 and 9.30 mg/kg for BHT, BHA, PG, OG and TBHQ, respectively.
Resumo:
In this work, a methodology for the characterization of sugar cane bagasse was validated. Bagasse pre-treated with steam in a 5000 L reactor at a pressure of 15.3 kgf/cm², during 7 min, was used to test the methodology. The methodology consisted of the hydrolysis of the material with H2SO4 at 72% v/v, for the quantification of carbohydrates, organic acid, furfural and hydroxymethylfurfural by HPLC; insoluble lignin and ash by gravimetry; and soluble lignin by spectrophotometry. Linearity, repeatability, reproducibility and accuracy of the results obtained in two Research Laboratories were determined, and were considered to be suitable for the validation of the methodology.
Resumo:
The most widespread literature for the evaluation of uncertainty - GUM and Eurachem - does not describe explicitly how to deal with uncertainty of the concentration coming from non-linear calibration curves. This work had the objective of describing and validating a methodology, as recommended by the recent GUM Supplement approach, to evaluate the uncertainty through polynomial models of the second order. In the uncertainty determination of the concentration of benzatone (C) by chromatography, it is observed that the uncertainty of measurement between the methodology proposed and Monte Carlo Simulation, does not diverge by more than 0.0005 unit, thus validating the model proposed for one significant digit.
Resumo:
The validation of analytical methods is an important step in quality control. The main objective of this study is to propose an HPLC experiment to verify the parameters of validation of chromatographic methods, based on green chemistry principles, which can be used in experimental courses of chemistry and related areas.
Resumo:
The presence of chloramphenicol residues in goat milk can cause toxic effects in the population. The present work consists of the optimization and validation of analytical methodology for determination of chloramphenicol residues in goat milk by GC/ECD. The extraction was made with ethyl acetate and the clean-up with SPE-C18. The identification was made by comparison of retention time and GC/MS, and the quantification by external standard. The method was selective, linearity (0.998), precise (5.8-13.4%), exact (69.87-73.71%) and robust. The LOD and LOQ of method were 0.030 and 0.10 μg/kg, respectively. The method was efficiently for analysis of chloramphenicol in goat milk.
Resumo:
An analytical method has been developed and validated for the determination of an association of ampicillins in a lyophilized powder for injection by HPLC. The advantage of chromatographic method other than the microbiological one is that, it is possible to monitor precisely, out-of-specification results in quality control processes and also during stability studies, in which an association of ampicillins is present. The proposed HPLC method was developed by using forced degraded samples, in order to reach a selective analysis of ampicillins when in the presence of their degradation products. It was possible to detect benzatine and through indirect calculation, to determine the ampicillin sodium in the drug sample. The method showed to be selective, accurate, precise, robust and linear (from 45.92 to 36.04 μg mL-1 of total ampicillin and from 14.53 to 43.28 μg mL-1 of benzatine). The accuracy determined from recovery test, gave results in the range of 99.41% of total ampicillin to 100.31% of benzatine. Hence, it can be concluded that the proposed HPLC method is applicable for ampicillins determination.
Resumo:
Three analytical methods for the determination of BTEX in water were optimized and validated. With the best method the analytes were extracted of 10 mL of sample with 2.50 g of NaCl in headspace vial of 20 mL by HS and SPME to 40 ºC for 30 min for adsorption and to 250 ºC for 4 min for desorption and were analyzed by GC-MS. The recovery was between 97.9% and 104.3%, and the limit of detection was 2.4 ng L-1 for o-xylene. This method was using to analyze BTEX in water supply and surface water in Ouro Preto city. No sample had concentrations of BTEX above the legislation.
Resumo:
Spectrophotometric methods of zero order, first and second derived order had been developed for olanzapine determination in tablets using ethanol and isopropanol as solvent. The two solvents revealed to be adequate. For the three methods the calibration curve coefficient of correlation had been greater than 0.9998 with limit of detection varying from 0.068 to 0.190 mg L-1, in ethanol, and 0.026 to 0.205 mg L-1, in isopropanol. The inter-day precision was inferior to 1.1 and 1.9 mg L-1 for ethanol and isopropanol, respectively. The average recoveries varied from 98 to 101%, in ethanol and 99 to 103% in isopropanol.
Resumo:
This work reports the validation of an analytical UV spectrophotometric method to assay acyclovir in hydrophilic matrices (assay and dissolution studies). The method was linear in the range between 2.5-20 µg mL-1, presenting a good correlation coefficient ( r = 0,9999). Precision and accuracy analysis showed low relative standart deviation (< 2.0 %) and a good recoveries percentual (98.9-100 %). The procedure was linear, accurate, and robust. The method is simple and cheap. It does not use polluting reagents and can be applied in dissolution studies, being an adequate alternative to assay acyclovir in hydrophilic matrices tablets.
Resumo:
The aim of this work was the single-laboratory validation of a quantitative method for the determination of amoxicillin residues in support of cleaning control and validation. Linearity was demonstrated between 2.5 and 17.5 μg/mL, without matrix effects. Mean recoveries ranged from 84.00 to 103.74% and the relative standard deviation under repetitivity and within-reproducibility conditions were from 0.58 to 4.20% and from 0.79 to 4.39%, respectively. The theoretical limits of detection and quantification were 0.133 and 0.442 μg/mL, respectively. The studied method was suitable for cleaning control purpose within good manufacturing practices.
Resumo:
ε-Caprolactam (CAP) is a monomer of nylon 6 used as food packaging for bologna sausage, turkey blanquettes, fowl breast, pâtés and ham luncheon meat. After polymerization a part of the monomer can remain in the packaging and migrate into the food. The aim of this work was develop and validate a single laboratory method to determine CAP in ethanol 95% that simulates fatty food characteristics. Thus, linear range was 2 to 32 mg/L of CAP, detection and quantification limits were 0.83 and 1.63 mg/L, respectively. Repeatability showed Hor Rat values lower than 2 while recovery range was 97.5 to 106.5%. The method was considered adequate for purpose.
Resumo:
The organic acids (tartaric, malic, citric, lactic and succinic) are de main components responsible for the acidity in the wine. This method for simultaneous determination of organic acids and interfering peaks in wines can be achieved in 16 min. The sample preceded by a dilution and filtration step. The chromatographic separation required one reversed phase column, isocratic mobile phase (acetonitrila, formic acid in water) and detection wavelength was set at 212 nm. The validation confirmed good repeatability, recovery and application in red and white wines.