467 resultados para Técnicas de Estimativa


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the development of electroanalytical methodologies for the determination of atrazine, ametrine and simazine by square wave voltammetry on a mercury electrode. For pure atrazine and pure ametrine, the detection limits (DL) were 3.7 and 4.3 µg L-1, respectively, while they increased to 4.8 and 6.5 µg L-1 in the presence of 3.0 x 10-6 mol L-1 of the other component (a mathematical deconvolution program was used in the mixture cases). The voltammetric response for simazine could not be separated from that of atrazine and measurements were carried out only in pure simazine solutions (DL: 7.5 µg L-1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of Nuclear Magnetic Resonance spectroscopy to establish the three-dimensional structures of molecules is an important component of modern Chemistry courses. The combination of techniques that can be used for this purpose is conveniently illustrated by their application to the camphor molecule. This paper presents applications of several techniques used in NMR spectral interpretation in an increasing order of complexity. The result of individual experiments is illustrated in order to familiarize the user with the way connectivity through bonds and through space is established from 1D/2D-NMR spectra and molecular stereochemistry is determined from different NMR experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we present procedures for the treatment and final disposal of residual solutions containing chromium, in order to evaluate the effectiveness of chemical precipitation of the metal and the potential of the glass encapsulation technique, using broken laboratory glassware. The results demonstrated that pH-values convenient for chemical precipitation are between 10 - 11. With regard to Cr(OH)3 encapsulation, the leaching and solubilization tests allowed to classify the waste as non-dangerous and non-inert. Finally, it is pointed out that the adoption of waste management practices in universities should be encouraged, helping to train professionals skilled in good laboratory practices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents Pd determinations in bovine tissue samples containing palladium prepared in the laboratory, and CCQM-P63 automotive catalyst materials of the Proficiency Test, using instrumental thermal and epithermal neutron activation analysis and energy dispersive X-ray fluorescence techniques. Solvent extraction and solid phase extraction procedures were also applied to separate Pd from interfering elements before the irradiation in the nuclear reactor. The results obtained by different techniques were compared against each other to examine sensitivity, precision and accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the effectiveness of four screening techniques (three techniques of the diffusion method and one microdilution broth method) were compared. Evaluated were the ethanolic and dichloromethanic extracts of Miconia rubiginosa (Melastomataceae) against six standard bacteria (ATCC). The results showed statistical disagreement among the three diffusion techniques. Among the diffusion techniques, the well technique displayed the best result. However the microdilution broth method demonstrated to be the most adequate method to evaluate the antibacterial activity of plant crude extracts and pure compounds when compared to the other methodologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Extraction and clean-up are essential points in polycyclic aromatic hydrocarbon (PAHs) analysis in a solid matrix. This work compares extraction techniques and clean-up procedures for PAH analysis. PAH levels, their toxicological significance and source were also evaluated in the waters of the Cocó and Ceará rivers. The efficiency of PAH recovery was higher for the soxhlet and ultrasonic techniques. PAH recovery varied from 69.3 to 99.3%. Total PAH concentration (ΣHPA) varied from 720.73 to 2234.76 µg kg-1 (Cocó river) and 96.4 to 1859.21 µg kg-1 (Ceará river). The main PAH sources are pyrolytic processes and the levels were classified as medium so that adverse effects are possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pesticides can be quite useful in agricultural production, however, some pesticides after application can reach and contaminate the hydric resource. Pesticide monitoring must be careful because it is expensive and lengthy. Thus, in this work, a theoretical prediction was made using the approaches suggested by EPA-USA, the Groundwater Ubiquity Score index (GUS) and the Goss method associated with physicochemical properties of 27 pesticides used in a region in the south of Brazil. The results of this work led to the identification of the pesticides that should be prioritized in the environmental monitoring due to their high potential for contaminating water resources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work deals with paint decomposition methods for major, minor and trace elements determination. Three methods were investigated: (1) decomposition in closed quartz vessel and heating in microwave oven; (2) decomposition in open vessel using HNO3 and ashing, following the ASTM D 3335-85a method; and (3) decomposition in open vessel using HNO3 + HF and ashing. Paints of different types and colours were analyzed, in which several elements were determined using inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICP OES). It was observed that method (1) is appropriate for trace, minor and major elements determination, while method (3) is appropriate for Ti.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glass ionomer cements (GICs) are products of the acid-base setting reaction between an finely fluoro-alumino silicate glass powder and poly(acrylic acid) in aqueous solution. The sol gel method is an adequate route of preparation of the glasses used to obtain the GICs. The objective of this paper was to compare two powders: a commercial and an experimental and to investigate the structural changes during hardening of the cements by FTIR and Al MAS NMR. These analyses showed that the experimental glass powder reacted with organic acid to form the GICs and it is a promising material to manufacture dental cements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rainwater samples (bulk deposition samples) were collected in Pinheiro and Viana. Rainwater pHs were higher than the range usually expected for unpolluted rain (5.0-5.6). The highest values were found in the beginning of the rainy season. High concentrations of ammonium found in the rainwater samples could probably explain the high pHs. Grazing animals and other human activities, combined with soil characteristics and climatic conditions can be the potential factors controlling the rainwater concentrations of ammonium in Baixada Maranhense.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical comparison of three different techniques for quantitative profile of esters in cachaça is reported. The Ministério da Agricultura Pecuária e Abastecimento (MAPA) recommends the use of GC/FID or volumetry. Despite being laborious and lacking in chemical speciation, the volumetric technique for total ester content shows to be appropriate, reproducible, and accurate for the analysis of cachaça. However, the GC/FID suggested by MAPA, considering only ethyl acetate, shows inaccuracy, underestimating the total ester content by a median factor of 72%, mainly due to the absence of ethyl lactate analysis. On the other hand, the GC/MS technique that comprises the analysis and speciation of nine esters, including ethyl lactate, proved to be reproducible, simple, fast and accurate for the analysis of total ester content in cachaça. Thus, the total ester content results obtained using GC/FID must be considered with precaution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurement uncertainty is useful to estimate the confidence of analytical results. Nowadays, a result without the uncertainty statement cannot be considered reliable, but the scientific literature still lacks examples of the estimate of the measurement uncertainty. This paper presents a practical and reliable description of the measurement uncertainty estimation of the analytical determination of ethyl carbamate in cachaça by GC-IDMS. The isotope dilution technique (ID) associated with GC-MS was used to improve the accuracy. The uncertainty estimated corresponds to 10% of the mass fraction of ethyl carbamate (115 ± 11) ng/g, which is in agreement with ppb level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method to quantify lycopene and β-carotene in freeze dried tomato pulp by high performance liquid chromatography (HLPC) was validated according to the criteria of selectivity, sensitivity, precision and accuracy, and uncertainty estimation of measurement was determined with data obtained in the validation. The validated method presented is selective in terms of analysis, and it had a good precision and accuracy. Detection limit for lycopene and β-carotene was 4.2 and 0.23 mg 100 g-1, respectively. The estimation of expanded uncertainty (K = 2) for lycopene was 104 ± 21 mg 100 g-1 and for β-carotene was 6.4 ± 1.5 mg 100 g-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Following application herbicides usually reach the soil and undergo several dissipation processes which determine their effects on target organisms and on the environment. This work aimed to evaluate atrazine and mesotrione sorption in Oxisols and estimate their potential impact on the environment. We observed that atrazine sorption was influenced by soil organic matter content and its hydrophobic character. Clay fraction was the main factor influencing mesotrione sorption followed in a lesser extent by soil organic matter content. In contrast to atrazine, mesotrione retention was favored by the higher carboxylic substitution in the aliphatic chains of soil organic matter. Atrazine and mesotrione were considered compounds that are likely to pose an appreciable risk of causing deleterious effects on the environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Direct infusion electrospray ionization mass spectrometry in the negative ion mode, ESI(-)-MS and Fourier transform infrared spectroscopy (FTIR) were used together with partial least squares (PLS) as a tool to determine B3 adulteration (B3 - mixture of 3% v/v of biodiesel in diesel) with kerosene and residual oil.