112 resultados para Flame throwers


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nickel, although essential to plants, may be toxic to plants and animals. It is mainly assimilated by food ingestion. However, information about the average levels of elements (including Ni) in edible vegetables from different regions is still scarce in Brazil. The objectives of this study were to: (a) evaluate and optimize a method for preparation of vegetable tissue samples for Ni determination; (b) optimize the analytical procedures for determination by Flame Atomic Absorption Spectrometry (FAAS) and by Electrothermal Atomic Absorption (ETAAS) in vegetable samples and (c) determine the Ni concentration in vegetables consumed in the cities of Lorena and Taubaté in the Vale do Paraíba, State of São Paulo, Brazil. By means of the analytical technique for determination by ETAAS or FAAS, the results were validated by the test of analyte addition and recovery. The most viable method tested for quantification of this element was HClO4-HNO3 wet digestion. All samples but carrot tissue collected in Lorena contained Ni levels above the permitted by the Brazilian Ministry of Health. The most disturbing results, requiring more detailed studies, were the Ni concentrations measured in carrot samples from Taubaté, where levels were five times higher than permitted by Brazilian regulations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study proposes a method of direct and simultaneous determination of the amount of Ca2+ and Mg2+ present in soil extracts using a Calcium Ion-Selective Electrode and by Complexometric Titration (ISE-CT). The results were compared to those obtained by conventional analytical techniques of Complexometric Titration (CT) and Flame Atomic Absorption Spectrometry (FAAS). There were no significant differences in the determination of Ca2+ and Mg2+ in comparison with CT and FAAS, at a 95 % confidence level. Additionally, results of this method were more precise and accurate than of the Interlaboratorial Control (IC).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to produce citrus somatic asymmetric hybrids by fusing gamma-irradiated protoplasts with iodoacetamide-treated protoplasts. Protoplasts were isolated from embryogenic suspension cells of grapefruit (Citrus paradisi Macfad.) cultivars Ruby Red and Flame, sweet oranges (C. sinensis Osbeck) 'Itaboraí', 'Natal', Valencia', and 'Succari', from 'Satsuma' (C. unshiu Marcow.) and 'Changsha' mandarin (C. reticulata Blanco) and 'Murcott' tangor (C. reticulata x C. sinensis). Donor protoplasts were exposed to gamma rays and receptor protoplasts were treated with 3 mmol L-1 iodoacetamide (IOA), and then they were fused for asymmetric hybridization. Asymmetric embryos were germinated, and the resulting shoots were either grafted onto sour orange, rough lemon or 'Swingle' (C. paradisi x Poncirus trifoliata) x 'Sunki' mandarin rootstock seedlings, or rooted after dipping their bases in indol-butyric acid (IBA) solution. The products were later acclimatized to greenhouse conditions. Ploidy was analyzed by flow cytometry, and hybridity was confirmed by amplified fragment length polymorphism (AFLP) analysis of plantlet DNAsamples. The best treatment was the donor-recipient fusion combination of 80 Gy-irradiated 'Ruby Red' protoplasts with 20 min IOA-treated 'Succari' protoplasts. Tetraploid and aneuploid plants were produced. Rooting recalcitrance was solved by dipping shoots' stems in 3,000 mg L-1 IBA solution for 10 min.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this work was to investigate possible maternal effects on potassium content of common bean seeds, as well as to estimate the heritability and selection gains in early hybrid generations for this character and to evaluate the efficiency of genetic selection to improve the nutritional quality of common bean (Phaseolus vulgaris). Crosses with four cultivars from the Mesoamerican gene pool yielded the reciprocal F1 and F2 generations and the backcrossed populations (BCP1 and BCP2). The potassium content of the progenies was measured via nitric‑perchloric digestion and flame photometry. The potassium content in the tested progenies varied from 6.0 to 14.9 g kg-1 dry matter, and no significant maternal effect was observed. The narrow-sense heritability ranged from low (33.26%) to intermediate (43.05%). Partial dominance was observed for low potassium content in the seeds. No increase in potassium content was obtained through selection. Breeding common bean plants for increasing potassium content in seeds may be difficult because the local environment strongly influences the character.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Con el objetivo de evaluar el nivel de aceptabilidad con relación a distintas variedades de uva de mesa, la Unidad de Comercialización y Divulgación Agraria del Departamento de Economía y Ciencias Sociales Agrarias (E.T.S.I.Agrónomos), de la Universidad Politécnica de Madrid, realizó la presente investigación en julio de 1999. Se utilizó el análisis sensorial en Sala de Catas como herramienta para la evaluación del nivel de aceptabilidad de cinco variedades de uva de mesa. Se puso énfasis en conocer las posibles diferencias de carácter sensorial entre las variedades Flame Seedless, Cardinal, Superior Seedless, Victoria y Redgloble, variedades que coinciden en su época de cosecha en España. En los análisis hechos, las variedades Cardinal y Superior Seedless fueron las más preferidas en comparación con Flame Seedless, Victoria y Redgloble. La variedad Superior Seedless fue muy valorada por su ausencia de semillas, además de su buen sabor, lo que la torna de gran potencial para el mercado español. El sabor, seguido de la jugosidad, fueron los elementos determinantes en el proceso de aceptación de la uva.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work describes a rapid and sensitive method for the determination of carbon monoxide and carbon dioxide at low concentration levels, on line, in ethylene and hydrogen lines. These gases were separated in a column filled with Porapak Q, converted to methane and quantified by a flame ionization detector. Some modifications were made in the injection system and in the lines of the carrier gas. The detection limits of 2,6 ppbV and 4,85 ppbV for CO and CO2, respectively, were reached after modifications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An automatic system for the direct determination of lead and tin by atomic absorption spectrometry is described. The on-line treatment of the metallic samples was obtained by anodic electrodissolution in a flow injection system. Lead was determined by flame atomic absorption spectrometry (FAAS) and tin by graphite furnace atomic absorption spectrometry (GFAAS). A computer program managed the current source and the solenoid valves that direct the fluids. Good linear correlations between absorbance and current intensity for lead and tin were observed. Results were in agreement with the certified values. Precision was always better than 5%. The recommended procedure allows the direct determination of 60 or 30 elements/h using FAAS or GFAAS, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to evaluate the chromium contamination from tannery discharges into rivers in the State of Minas Gerais, samples of water and suspended material were collected and submitted to chemical analysis. The total content of chromium in the samples was measured by flame atomic absorption spectrophotometry. Water samples were analysed by standard addition method, while chromium concentration in suspended materials was determined by calibration curves. Localities investigated were Ipatinga, Matias Barbosa, Dores de Campo, Ressaquinha, Ubá and Juiz de Fora. Samples from a not-industrialized area were also analysed to obtain regional background values. Metal inputs were related to effluent discharges into the rivers. Suspended material transported Cr downriver. Chromium concentration in river water exceeded 656 times the value of the Brazilian Environmental Standards, while its concentration in suspended material ranged from 15 to 11066 µg g-1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

'Cachaça' is the Brazilian name for the spirit obtained from sugarcane. According to Brazilian regulations, it may be sold raw or with addition of sugar and may contain up to 5 mg/L of copper. Copper in "cachaça" was determined by titration with EDTA, using a homemade copper membrane electrode for end-point detection. It was found a pooled standard deviation of 0,057 mg/L and there was no significant difference between the results obtained by the potentiometric method and by flame atomic absorption spectrometry with standard addition. Among the 21 'cachaça' samples from 16 different brands analyzed, three overpassed the legal copper limit. For its characteristics of accuracy, precision, and speed, the potentiometric method may be employed advantageously in routine analysis, specially when low cost is a major concern.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes in detail a technique employed to grow quasi-spherical single crystals of noble metals for electrochemical applications, using platinum as an example. The metal beads were formed by melting the extremity of a wire in an oxygen / butane flame. X-ray techniques were used to check the crystallization and to determine the orientation of the crystals. Treatment with a pure hydrogen flame followed by a cooling procedure in a hydrogen / argon atmosphere were used for conditioning the well-defined platinum single crystal surfaces. Finally, electrochemical characterization of the Pt(111), Pt(110) and Pt(100) surfaces was done in diluted sulfuric acid solution in the hydrogen adsorption / desorption potential region.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a system for electrochemical hydride generation using flow-injection and atomic absorption spectrometry to determine selenium in biological materials. The electrolytic cell was constructed by assembling two reservoirs, one for the sample and the other for the electrolytic solution separated by a Nafion membrane. Each compartment had a Pt electrode. The sample and electrolyte flow-rates, acidic media, and applied current were adjusted to attain the best analytical performance and ensure the membrane lifetime. The atomisation system used a T quartz tube in an air-LPG flame. The composition of the flame, the observation height, and the argon flow rate used to carry the hydrides were critically investigated. The system allowed to perform thirty determinations per hour with a detection limit of 10 mug L-1 of Se. Relative standard deviations were in general lower than 1.5% for a solution containing 20.0 and 34.0 mug L-1 of Se in a typical sample digest. Accuracy was assessed analysing the certified materials: rice flour (NIST-1568) from National Institute of Standard and Technology and dried fish (MA-A-2), whole animal blood (A-2/1974) from the International Atomic Energy Agency.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article describes the combination of low- and high-pressure flow systems for the determination of Magnesium, Calcium and Strontium by flame atomic absorption spectrometry (FAAS). In the low-pressure system a short C-18 RP column (length 0,5 cm) was utilized for the preconcentration/matrix separation step, xylenol orange was used as chelating agent and tetrabutylamonium acetate for ion pair formation. The hydraulic high pressure nebulization (HHPN) was used for sample transport and sample introduction in the high pressure system. The repeatabilities and detection limits for Mg, Ca and Sr were determined and compared with those obtained by pneumatic nebulization (PN). The results show that the detection limits obtained using the HHPN for Mg, Ca and Sr are between 1.5 to 2 times better than those obtained by PN when the signal transient was measured in area. The system presented a sampling frequency of 130 h-1 for direct determination of Mg, Ca or Sr in samples of saturated sodium chloride used in the production of chlorine and sodium hydroxide.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present work four different analytical methodologies were studied for the determination of iron and titanium in Portland cement. The cement samples were dissolved with hot HCl and HF, being compared Fe and Ti concentrations through four analytical methods: molecular absorption spectrophotometry using the reagents 1,2-hydroxybenzene-3,5-disulfonic acid (Tiron) and the 5-chloro-salicylic acid (CSA), inductively coupled plasma atomic emission spectrometry (ICP-AES) and flame atomic absorption spectrophotometry (FAAS). In the spectrophotometric determinations were studied pH conditions, reagents addition order, interferences, amount of reagents, linear range and stability of the system. In the techniques of ICP-AES and FAAS were studied the best lines, interferences, sensibility and linear range. The obtained results were compared and the agreement was evaluated among the methods for the determination of the metals of interest.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Calculation of uncertainty of results represents the new paradigm in the area of the quality of measurements in laboratories. The guidance on the Expression of Uncertainty in Measurement of the ISO / International Organization for Standardization assumes that the analyst is being asked to give a parameter that characterizes the range of the values that could reasonably be associated with the result of the measurement. In practice, the uncertainty of the analytical result may arise from many possible sources: sampling, sample preparation, matrix effects, equipments, standards and reference materials, among others. This paper suggests a procedure for calculation of uncertainties components of an analytical result due to sample preparation (uncertainty of weights and volumetric equipment) and instrument analytical signal (calibration uncertainty). A numerical example is carefully explained based on measurements obtained for cadmium determination by flame atomic absorption spectrophotometry. Results obtained for components of total uncertainty showed that the main contribution to the analytical result was the calibration procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes a sequential injection analysis (SIA) set-up coupled to a flame atomic absorption spectrometer (FAAS) to accomplish the determination of low concentrations of copper in drinking waters. Copper is first retained under neutral media in an on-line 29x1.6 mm column filled with poly(ethylenimine) immobilised on silica gel. The retained analyte is then eluted by flowing through the column 250 mL of a nitric acid solution. The selection of 3.85 ml of sample enabled to obtain a detection limit of 0.27 mug/L and a sampling rate of about 24 samples/h. There was a good agrement between the results of 12 samples furnished by the proposed procedure and by electrothermal atomic absorption spectrometry. Repeatability assessment gave a relative standard deviation of 1.3 % after ten replicate analysis of a sample containing about 70 mug/L in copper..