474 resultados para eficiência de remoção
Resumo:
This work optimized the HPLC conditions for the simultaneous determination of luteolin, apigenin, myricetin, quercetin and kaempferol in aglycone form, as well defined the best conditions for hydrolysis/extraction of these flavonoids in fruits, using the statistical central composite design and response surface analysis. A reverse phase method was developed using a gradient of methanol/water acidified with 0.3% formic acid as mobile phase and a photodiode array detector. The samples were extracted with methanol/water (50:50 v/v) at 90 ºC. The optimum time and HCl concentration varied for the different fruits investigated, demonstrating the necessity of optimizing these conditions for each fruit analyzed. Good recovery (87.1 to 96.3%), repeatability and linearity were obtained.
Resumo:
A HPLC method was developed to quantify thymine and thymidine impurities in stavudine bulk drug. The separation was carried out in isocratic mode using methanol/water (20:80) as mobile phase, a C18 column and UV detection at 266 nm. The method provided selectivity based on peak purities and resolution among peaks. It was linear over the range of 0.5-5.0 µg/mL. The quantitation limits were 0.021 µg/mL for thymine and 0.134 µg/mL for thymidine. The average accuracies of three concentrations ranged from 97.06 to 102.61% and precision was close to 1%. The method showed robustness, remaining unaffected by deliberate variations in relevant parameters.
Resumo:
A simple liquid chromatographic method for the simultaneous determination of creatinine, hippuric acid, mandelic acid, phenylglyoxylic acid and o, m and p-methylhippuric acids was developed and validated. Sample preparation was only dilution with water (1:10), followed by centrifugation. Analysis was performed in a reversed phase column (Lichrospher RP 8ec), 250 x 4.0 mm, with isocratic elution with phosphate buffer pH 2.3 and acetonitrile (90:10, v/v). The method presents adequate linearity, precision and accuracy and allows the simultaneous determination of the biomarkers of exposure to toluene, xylene and styrene together with creatinine, reducing cost and laboratory time.
Resumo:
Bupivacaine (S75-R25, NovaBupi®) is an amide type local anesthetic widely used. The present work consists of the development and validation of analytical methodology for evaluation of NovaBupi® content in the poly-lactide-co-glycolide nanospheres (PLGA-NS) by high performance liquid chromatography. The separation was made using the reversed-phase column LC-18, acetonitrile/phosphate buffer 85:15 v/v as mobile phase and detection at 220 nm. The results obtained show that the analytical methodology is accurate, reproducible, robust and linear over the concentration range 10-220.0 g/mL of NovaBupi®. The method was applied to determine the encapsulation efficiency and evaluate the release profile of NovaBupi®, showing good results.
Resumo:
Characterization of fish scales of Leporinus elongatus and their application in the removal of Cu(II) from aqueous solutions are described. It was observed that the scales are mainly formed by hydroxyapatite and type I collagen. Adsorption of Cu(II) was performed using batch experiments at 25 0C. The ANOVA statistical results have shown that the Langmuir model was successful applied to determine the maximum adsorption capacity of 2.686 x10-4 mol g-1 and the Langmuir equilibrium parameter (b) of 168.8 L mol-1. The Langmuir separation parameter, R L, has shown favorable adsorption of Cu(II) on the scales.
Resumo:
A high performance liquid chromatography (HPLC) method has been developed for a rapid determination of nimesulide in dissolution studies. Nimesulide was analyzed using 5 µm Lichrospher® RP-18 column (125 x 4 mm i.d.) and mobile phase acetonitrile: phosphate buffer pH=6.0 (55:45) at a flow-rate of 1.0 mL min-1. Detection was carried out at 300 nm at 25 ºC. The method was applied to analysis of nimesulide in in vitro release studies and showed a rapid and efficient analytical alternative for evaluation of dissolution profile of nimesulide.
Resumo:
Ultra Performance Liquid Chromatography (UPLC) retains the same principles as High Performance Liquid Chromatography (HPLC), but uses 1-2.1 mm i.d. columns with sub-2 µm particles. It is considered the newest advance in analytical separation science. The use of these small particles with mobile phases at high linear velocities increases resolution and detectability and decreases analysis time. Thus, the analyses are faster, the solvent volume is smaller, the efficiency is higher and the detectability is 2-3 times higher when compared with HPLC analysis.
Resumo:
High copper content is of great concern among producers of sugar-cane spirits who frequently use filters instead of cleaning the stills. This study compared the efficiency of activated carbon, ion-exchange-polymeric resin, and activated-carbon/iron-oxide magnetic composite for copper reduction without removing excessive organic compounds that are important for the beverage's quality. Resin was the most efficient copper adsorbent, removing fewer organic compounds. The composite also removed copper; however, it also removed large amounts of organic compounds. Activated carbon didn't remove sufficient copper to reduce its concentration to less than 5 g L-1, and it removed large amounts of higher alcohols and esters.
Resumo:
Batch sorption experiments were carried out to remove methylene blue from its aqueous solutions using zeolites synthesized from fly ashes as an adsorbent. The adsorbents were characterized by XFR, XRD and SEM. Nearly 90 min of contact time are found to be sufficient for the adsorption of dye to reach equilibrium. Equilibrium data have been analyzed using Langmuir and Freundlich isotherms and the results were found to be well represented by the Freundlich isotherm equation. Adsorption data were fitted to both Lagergren first-order and pseudo-second-order kinetic models and the data were found to follow pseudo-second-order kinetics.
Resumo:
This paper describes the development and validation of simple and selective analytical method for determination of 3.4-methylenedioxymethamphetamine (MDMA) in Ecstasy tablets, using high performance liquid chromatography with fluorescence detection. Analysis was performed in a reversed phase column (LiChrospher 100 C18, 150 x 4.6 mm, 5 µm), isocratic elution with phosphate buffer 25 mmol/L pH 3.0 and acetonitrile (95:5, v/v). The method presents adequate linearity, selectivity, precision and accuracy. MDMA concentration in analyzed tablets showed a remarkable variability (from 8.5 to 59.5 mg/tablet) although the tablet weights were uniform, indicating poor manufacturing control thus imposing additional health risks to the users.
Resumo:
The aim of this study was to verify the influence of the apparent molecular size of aquatic humic substances on the effectiveness of coagulation with ferric chloride. Coagulation-filtration tests using jar test and bench-scale sand filters were carried out on samples of water with true color of approximately 100 Hazen units, prepared with aquatic humic substances of different molecular sizes (F1: < 0.45 µm, F2: 100 kDa - 0.45 µm, F3: 30 - 100 kDa and F4': < 30 kDa). For the water samples with lower apparent molecular size fractions, greater dosages of coagulant was needed to remove the color around 5.0 Hanzen units, mainly because these water samples contain higher concentrations of fulvic acids, which exhibited a larger number of negatively-charged groups.
Resumo:
Valproic acid (VA) is a drug used to control seizures in several epileptic conditions. In VA pharmacotherapy, therapeutic drug monitoring is recommended to obtain adequate seizure control and avoid toxicity. The aim of this study was to validate a method for the determination of valproic acid in serum, employing high performance liquid chromatography with diode array detection (HPLC-DAD), after derivatization with phenacyl bromide. The calibration curve (y=0.0133x-0.0025) presented good linearity with r²=0.9999. Accuracy (101-115%), intra-assay precision (4.53-8.15%) and inter-assay precision (3.15-6.77%) were acceptable. The quantification limit was 2.0 µg/mL. The method presented similar results to enzyme immunoassay.
Resumo:
The oxidation of arsenic (As(III) to As(V)) in water samples was performed by heterogeneous photocatalysis using a TiO2 film immobilized inside a photochemical reactor. After oxidation, As(V) was removed from the water samples by coprecipitation with ferric sulfate. The final conditions of oxidation and arsenic removal (TiO2 film prepared with a suspension: 10% (w/v); pH: 7.0; oxidation time: 30 min and Fe3+ concentration: 50 mg L-1) were applied in natural water samples which were supplemented with 1.0 mg L-1 of As(III) to verify the influence of the matrix. After treatment, more than 99% of arsenic was removed from the water.
Resumo:
In this work, composites based on activated carbon/iron oxide (AC/Fe) were prepared in two different proportions (AC/Fe 5/1 and 1/1) and evaluated in the removal of the organic dye methylene blue (MB). Physical-chemical properties of the composites were determined by X-ray diffraction (XRD), adsorption/dessorption of N2 isotherm, temperature programmed reduction (TPR) and scanning electron microscopy (SEM). Results showed that goethite (α- FeOOH), with nanometer particle size, was formed over carbon surface for both composites. These materials showed high efficiency to remove MB from solution by combined adsorption and oxidation process. The AC/Fe 1/1 showed to be more active in (MB) oxidation then AC/Fe 5/1.
Resumo:
The metal ions removal on cashew bagasse, a low-cost material, has been studied by batch adsorption. The parameters chemical treatment, particle size, biosorbent concentration, and initial pH were studied. In this study the maximum ions removal was obtained on the cashew bagasse treated with 0.1 mol/L NaOH/3 h, at optimum particle size (20-59 mesh), biosorbent concentration (50 g/L) and initial solution pH 5. The kinetic study indicated that the adsorption metal follows pseudo-second order model for a multielementary system and equilibrium time was achieved in 60 min for all metal ions.