349 resultados para Sensorial test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hedonic level of commercial cachaças, was evaluated by consumers and by a tasters. The results of sensorial methods analyzed trough Principal Components Analysis, Hierarchical Cluster Analysis and the Pearson linear correlation indicated that the best classified cachaças were produced in copper stills and aged in oak casks. By contrast the worst classified exhibited as the main features be not aged and high alcohol percentage. The index of preference is positively correlated with the intensity of yellow color, wood flavor, sweetness and fruit aroma. There is a negative preference correlation with the acidity, the taste of alcohol and bitterness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the development and validation of a dissolution test for 50 mg losartan potassium capsules using HPLC and UV spectrophotometry. A 2(4) full factorial design was carried out to optimize dissolution conditions and potassium phosphate buffer, pH 6.8 as dissolution medium, basket as apparatus at the stirring speed of 50 rpm and time of 30 min were considered adequate. Both dissolution procedure and analytical methods were validated and a statistical analysis showed that there are no significant differences between HPLC and spectrophotometry. Since there is no official monograph, this dissolution test could be applied for quality control routine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aimed the development and validation of a new dissolution test for ornidazole coated tablets. The dissolution conditions were determined after testing Sink conditions, dissolution medium, apparatus, stirring speed, 24 h stability and medium filtration influence. The best conditions were paddle at a stirring speed of 75 rpm and 900 mL of 0.1 M HCl. A new HPLC quantification method was developed and validated. The dissolution test and quantification method showed to be adequate for their purposes and could be applied for quality control of ornidazole coated tablets, since there is no official monograph.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the analytical application of a novel electronic tongue based on voltammetric sensors array. This device was used in the classification of wines aged in barrels of different origins and toasting levels. Furthermore, a study of correlation between the response of the electronic tongue and the sensory and chemical characterization of samples was carried out. The results were evaluated by applying both principal component analysis and cluster analysis. The samples were clearly classified. Their distribution showed a high correspondence degree with the characteristics of the analyzed wines, it also showed similarity with the classification obtained from organoleptic analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dissolution test for in vitro evaluation of tablet dosage forms containing 10 mg of rupatadine was developed and validated by RP-LC. A discriminatory dissolution method was established using apparatus paddle at a stirring rate of 50 rpm with 900 mL of deaerated 0.01 M hydrochloric acid. The proposed method was validated yielding acceptable results for the parameters evaluated, and was applied for the quality control analysis of rupatadine tablets, and to evaluate the formulation during an accelerated stability study. Moreover, quantitative analyses were also performed, to compare the applicability of the RP-LC and the LC-MS/MS methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple liquid chromatographic method was optimized for the quantitative determination of terbinafine in pharmaceutical hydroalcoholic solutions and tablets, and was also employed for a tablet dissolution test. The analysis was carried out using a RP-C18 (250 mm × 4.6 mm, 5 μm) Vertical® column, UV-Vis detection at 254 nm, and a methanol-water (95:5, v/v) mobile phase at a flow-rate of 1.2 mL min-1. Method validation investigated parameters such as linearity, precision, accuracy, robustness and specificity, which gave results within the acceptable range. The tablets dissolution was quite fast: 80% of the drug was dissolved within 15 min.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the development and validation of a dissolution test for 60 mg of diltiazem hydrochloride in immediate release capsules. The best dissolution in vitro profile was achieved using potassium phosphate buffer at pH 6.8 as the dissolution medium and paddle as the apparatus at 50 rpm. The drug concentrations in the dissolution media were determined by UV spectrophotometry and HPLC and a statistical analysis revealed that there were significant differences between HPLC and spectrophotometry. This study illustrates the importance of an official method for the dissolution test, since there is no official monograph for diltiazem hydrochloride in capsules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, precise, specific, repeatable and discriminating dissolution test for primaquine (PQ) matrix tablets was developed and validated according to ICH and FDA guidelines. Two UV assaying methods were validated for determination of PQ released in 0.1 M hydrochloric acid and water media. Both methods were linear (R²>0.999), precise (R.S.D.<1.87%) and accurate (97.65-99.97%). Dissolution efficiency (69-88%) and equivalence of formulations (f2) was assessed in different media and apparatuses (basket/100 rpm and paddle/50 rpm) tested. Discriminating condition was 900 mL aqueous medium, basket at 100 rpm and sampling times at 1, 4 and 8 h. Repeatability (R.S.D.<2.71%) and intermediate precision (R.S.D.<2.06%) of dissolution method were satisfactory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article outlines a procedure that was used to develop a written test for evaluating the conceptual knowledge of chemical equilibrium constant among university students. The concepts in the subject matter were carefully defined through propositional statements. Students' understanding of the topic was determined through interviews. These data were used to produce nine multiple choice questions. Each question was designed to identify misconceptions related to the chemical equilibrium constant. The test was evaluated by foure associate professors and was administred to a total of 196 spanish university students. This test has a Cronbach's alpha reliability of 0.63 and its content validity values ranged from 3.7 to 5.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A qualitative spot-test and tandem quantitative analysis of dipyrone in the bulk drug and in pharmaceutical preparations is proposed. The formation of a reddish-violet color indicates a positive result. In sequence a quantitative procedure can be performed in the same flask. The quantitative results obtained were statistically compared with those obtained with the method indicated by the Brazilian Pharmacopoeia, using the Student's t and the F tests. Considering the concentration in a 100 µL aliquot, the qualitative visual limit of detection is about 5×10-6 g; instrumental LOD ≅ 1.4×10-4 mol L-1 ; LOQ ≅ 4.5×10-4 mol L-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work established the adequate temperature and the period of exposition for the accelerated ageing test with diasporas of Myracrodruon urundeuva from an area of the Cerrado in the state of Mato Grosso, Brazil. Before and after the ageing, at the temperatures of 40ºC, 41ºC, 42ºC and 45ºC combined with periods of 12, 18, 24, 30 and 36 hours, the water content and germination were evaluated. For each treatment, 12g of diasporas in mini chambers with 40 mL of distilled water were submitted to the accelerated ageing test. A total of 100 diasporas, divided into four replications, in plastic boxes, on two sheets of blotting paper, in germinator at 25ºC and 8 hours of photoperiod were germinated. In all treatments the content of water of the aged diasporas was superior to 20% and this value stabilized itself between 25% and 28%, from the 18 hours of exposition. Independently of the tested periods, the ageing at the temperatures of 40ºC, 41ºC and 42ºC did not affect the germination. After the ageing at 45ºC, the germination did not differ among the periods of 12, 18 and 24 hours of exposition, but in all these periods it was inferior to the control and superior to the periods of 30 and 36 hours. In these last two periods, fungi were observed. The accelerated ageing of diasporas of Myracrodruon urundeuva should be conducted at the temperature of 45ºC, during the exposition periods of 12 to 24 hours.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os métodos atualmente utilizados para realização de análise sensorial têm deixado muito a desejar por não traduzir satisfatoriamente os resultados. Diante deste problema, analisou-se a possibilidade de introdução de um fator que medisse o índice de concordância dos provadores sobre determinado aspecto analisado. Para validação deste coeficiente, foi avaliada a concordância entre julgadores na análise sensorial para três diferentes amostras de suco de pinha (Annona squamosa L.): uma constituída apenas do suco de pinha sem leite e duas com diferentes concentrações pinha/leite. Utilizou-se a Análise de Componentes Principais (ACP) e também a nova metodologia proposta pelos autores, com base na definição do desvio-padrão, aplicada às frequências absolutas das notas dos julgadores, para cada propriedade sensorial estudada. Com esta metodologia, definiu-se uma relação para o cálculo de uma medida de concordância entre os julgadores, denominada de coeficiente de concordância, a qual pode assumir valores de 0 a 100% e também permite comparações que não são possíveis, utilizando-se da ACP. Por fim, concluiu-se que tal metodologia é mais indicada que a ACP, na avaliação da concordância entre os julgadores na análise sensorial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantifying soil evaporation is required on studies of soil water balance and applications aiming to improve water use efficiency by crops. The performance of a microlysimeter (ML) to measure soil evaporation under irrigation and non-irrigation was evaluated. The MLs were constructed using PVC tubes, with dimensions of 100 mm inner diameter, 150 mm depth and 2.5 mm wall thickness. Four MLs were uniformly distributed on the soil surface of two weighing lysimeters conducted under bare soil, previously installed at Iapar, in Londrina, PR, Brazil. The lysimeters had 1.4 m width, 1.9 m length and 1.3 m depth and were conducted with and without irrigation. Evaporation measurements by MLs (E ML) were compared with measurements by lysimeters (E L) during four different periods in the year. Differences between E ML and E L were small either for low or high atmospheric demand and also for either irrigated or non-irrigated conditions, which indicates that the ML tested here is suitable for measurement of soil evaporation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rural electrification is characterized by geographical dispersion of the population, low consumption, high investment by consumers and high cost. Moreover, solar radiation constitutes an inexhaustible source of energy and in its conversion into electricity photovoltaic panels are used. In this study, equations were adjusted to field conditions presented by the manufacturer for current and power of small photovoltaic systems. The mathematical analysis was performed on the photovoltaic rural system I-100 from ISOFOTON, with power 300 Wp, located at the Experimental Farm Lageado of FCA/UNESP. For the development of such equations, the circuitry of photovoltaic cells has been studied to apply iterative numerical methods for the determination of electrical parameters and possible errors in the appropriate equations in the literature to reality. Therefore, a simulation of a photovoltaic panel was proposed through mathematical equations that were adjusted according to the data of local radiation. The results have presented equations that provide real answers to the user and may assist in the design of these systems, once calculated that the maximum power limit ensures a supply of energy generated. This real sizing helps establishing the possible applications of solar energy to the rural producer and informing the real possibilities of generating electricity from the sun.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among studies focused on increasing soybean grain yield, the ones related to sowing process are the most significant. Considering that soybean has an epigeal emergence, it becomes difficult to hint at the length covered by hypocotyl up to soil surface, or the actual planting depth. This study aimed to find an indicator that allows the identification of an ideal soybean planting depth. For this purpose, two complementary assays has been carried out in a greenhouse. The first aimed to identify structures that could be indicators of seed planting depth, on a medium-textured soil from Campos Gerais region, in the state of Paraná, Brazil. Spring NK 8350 cultivar seeds were sown at five theoretical depths (1, 2, 3, 4 and 5 cm). As seedlings emerged, the “differentiation zone” and the “root curve” depths were measured. The second assay was the validation of the suggested indicators in assay 1 from two soils, one medium-textured and one clay-textured. For this assay, it was used BRS 232. Both the methodologies showed high correlation with the theoretical planting depth. Although their correlation coefficient values were close, the differentiation zone appeared to be the most efficient reference with less planting depth overestimation.