262 resultados para Berg test
Resumo:
This work report the seasonal variation of composition of the volatile oils from leaves and from flowers of Myrcia salzmannii harvested in the sand dunes of Salvador, Bahia, northeastern region of Brazil in the years 2001 and 2003. The oils were analyzed by GC-FID and GC-MS being identified 49 components. Nine essential oil samples of leaves collected on different months and years and one sample of flowers were analyzed. β-Caryophyllene and α-humulene were the only compounds present in all of the samples being the first the majority compound.
Resumo:
This work describes the development and validation of a dissolution test for 50 mg losartan potassium capsules using HPLC and UV spectrophotometry. A 2(4) full factorial design was carried out to optimize dissolution conditions and potassium phosphate buffer, pH 6.8 as dissolution medium, basket as apparatus at the stirring speed of 50 rpm and time of 30 min were considered adequate. Both dissolution procedure and analytical methods were validated and a statistical analysis showed that there are no significant differences between HPLC and spectrophotometry. Since there is no official monograph, this dissolution test could be applied for quality control routine.
Resumo:
This work aimed the development and validation of a new dissolution test for ornidazole coated tablets. The dissolution conditions were determined after testing Sink conditions, dissolution medium, apparatus, stirring speed, 24 h stability and medium filtration influence. The best conditions were paddle at a stirring speed of 75 rpm and 900 mL of 0.1 M HCl. A new HPLC quantification method was developed and validated. The dissolution test and quantification method showed to be adequate for their purposes and could be applied for quality control of ornidazole coated tablets, since there is no official monograph.
Resumo:
A dissolution test for in vitro evaluation of tablet dosage forms containing 10 mg of rupatadine was developed and validated by RP-LC. A discriminatory dissolution method was established using apparatus paddle at a stirring rate of 50 rpm with 900 mL of deaerated 0.01 M hydrochloric acid. The proposed method was validated yielding acceptable results for the parameters evaluated, and was applied for the quality control analysis of rupatadine tablets, and to evaluate the formulation during an accelerated stability study. Moreover, quantitative analyses were also performed, to compare the applicability of the RP-LC and the LC-MS/MS methods.
Resumo:
A simple liquid chromatographic method was optimized for the quantitative determination of terbinafine in pharmaceutical hydroalcoholic solutions and tablets, and was also employed for a tablet dissolution test. The analysis was carried out using a RP-C18 (250 mm × 4.6 mm, 5 μm) Vertical® column, UV-Vis detection at 254 nm, and a methanol-water (95:5, v/v) mobile phase at a flow-rate of 1.2 mL min-1. Method validation investigated parameters such as linearity, precision, accuracy, robustness and specificity, which gave results within the acceptable range. The tablets dissolution was quite fast: 80% of the drug was dissolved within 15 min.
Resumo:
This work describes the development and validation of a dissolution test for 60 mg of diltiazem hydrochloride in immediate release capsules. The best dissolution in vitro profile was achieved using potassium phosphate buffer at pH 6.8 as the dissolution medium and paddle as the apparatus at 50 rpm. The drug concentrations in the dissolution media were determined by UV spectrophotometry and HPLC and a statistical analysis revealed that there were significant differences between HPLC and spectrophotometry. This study illustrates the importance of an official method for the dissolution test, since there is no official monograph for diltiazem hydrochloride in capsules.
Resumo:
A simple, precise, specific, repeatable and discriminating dissolution test for primaquine (PQ) matrix tablets was developed and validated according to ICH and FDA guidelines. Two UV assaying methods were validated for determination of PQ released in 0.1 M hydrochloric acid and water media. Both methods were linear (R²>0.999), precise (R.S.D.<1.87%) and accurate (97.65-99.97%). Dissolution efficiency (69-88%) and equivalence of formulations (f2) was assessed in different media and apparatuses (basket/100 rpm and paddle/50 rpm) tested. Discriminating condition was 900 mL aqueous medium, basket at 100 rpm and sampling times at 1, 4 and 8 h. Repeatability (R.S.D.<2.71%) and intermediate precision (R.S.D.<2.06%) of dissolution method were satisfactory.
Resumo:
This article outlines a procedure that was used to develop a written test for evaluating the conceptual knowledge of chemical equilibrium constant among university students. The concepts in the subject matter were carefully defined through propositional statements. Students' understanding of the topic was determined through interviews. These data were used to produce nine multiple choice questions. Each question was designed to identify misconceptions related to the chemical equilibrium constant. The test was evaluated by foure associate professors and was administred to a total of 196 spanish university students. This test has a Cronbach's alpha reliability of 0.63 and its content validity values ranged from 3.7 to 5.
Resumo:
A qualitative spot-test and tandem quantitative analysis of dipyrone in the bulk drug and in pharmaceutical preparations is proposed. The formation of a reddish-violet color indicates a positive result. In sequence a quantitative procedure can be performed in the same flask. The quantitative results obtained were statistically compared with those obtained with the method indicated by the Brazilian Pharmacopoeia, using the Student's t and the F tests. Considering the concentration in a 100 µL aliquot, the qualitative visual limit of detection is about 5×10-6 g; instrumental LOD ≅ 1.4×10-4 mol L-1 ; LOQ ≅ 4.5×10-4 mol L-1.
Resumo:
This work established the adequate temperature and the period of exposition for the accelerated ageing test with diasporas of Myracrodruon urundeuva from an area of the Cerrado in the state of Mato Grosso, Brazil. Before and after the ageing, at the temperatures of 40ºC, 41ºC, 42ºC and 45ºC combined with periods of 12, 18, 24, 30 and 36 hours, the water content and germination were evaluated. For each treatment, 12g of diasporas in mini chambers with 40 mL of distilled water were submitted to the accelerated ageing test. A total of 100 diasporas, divided into four replications, in plastic boxes, on two sheets of blotting paper, in germinator at 25ºC and 8 hours of photoperiod were germinated. In all treatments the content of water of the aged diasporas was superior to 20% and this value stabilized itself between 25% and 28%, from the 18 hours of exposition. Independently of the tested periods, the ageing at the temperatures of 40ºC, 41ºC and 42ºC did not affect the germination. After the ageing at 45ºC, the germination did not differ among the periods of 12, 18 and 24 hours of exposition, but in all these periods it was inferior to the control and superior to the periods of 30 and 36 hours. In these last two periods, fungi were observed. The accelerated ageing of diasporas of Myracrodruon urundeuva should be conducted at the temperature of 45ºC, during the exposition periods of 12 to 24 hours.
Resumo:
O guabijuzeiro ocorre no Brasil desde São Paulo até o Rio Grande do Sul. Suas sementes são de curta longevidade e intolerantes à dessecação. O objetivo deste trabalho foi avaliar a qualidade fisiológica de sementes de guabijuzeiro ao longo de oito meses de armazenamento em câmara fria (5±1 ºC e 80% UR). Sementes de seis diferentes plantas localizadas os Municípios de Encruzilhada do Sul e Cachoeira do Sul, no Rio Grande do Sul, constituíram seis lotes, que foram avaliados quanto ao teor de água, à massa de mil sementes, à germinação, ao tempo médio de germinação em laboratório, à emergência e ao tempo médio de emergência em casa de vegetação. Até o terceiro mês de armazenamento, a viabilidade das sementes foi superior a 50%, porém três lotes apresentaram valores acima de 75%. Ao longo do período de armazenamento ocorreu pequena variação no teor de água (entre 40 e 45%), e as sementes de todos os lotes perderam qualidade. Contudo, aos oito meses foram registradas viabilidades entre 56% e 61% em sementes de dois lotes, mostrando que, em ambiente de câmara fria, é possível prolongar a longevidade de sementes de guabijuzeiro.
Resumo:
Quantifying soil evaporation is required on studies of soil water balance and applications aiming to improve water use efficiency by crops. The performance of a microlysimeter (ML) to measure soil evaporation under irrigation and non-irrigation was evaluated. The MLs were constructed using PVC tubes, with dimensions of 100 mm inner diameter, 150 mm depth and 2.5 mm wall thickness. Four MLs were uniformly distributed on the soil surface of two weighing lysimeters conducted under bare soil, previously installed at Iapar, in Londrina, PR, Brazil. The lysimeters had 1.4 m width, 1.9 m length and 1.3 m depth and were conducted with and without irrigation. Evaporation measurements by MLs (E ML) were compared with measurements by lysimeters (E L) during four different periods in the year. Differences between E ML and E L were small either for low or high atmospheric demand and also for either irrigated or non-irrigated conditions, which indicates that the ML tested here is suitable for measurement of soil evaporation.
Resumo:
The rural electrification is characterized by geographical dispersion of the population, low consumption, high investment by consumers and high cost. Moreover, solar radiation constitutes an inexhaustible source of energy and in its conversion into electricity photovoltaic panels are used. In this study, equations were adjusted to field conditions presented by the manufacturer for current and power of small photovoltaic systems. The mathematical analysis was performed on the photovoltaic rural system I-100 from ISOFOTON, with power 300 Wp, located at the Experimental Farm Lageado of FCA/UNESP. For the development of such equations, the circuitry of photovoltaic cells has been studied to apply iterative numerical methods for the determination of electrical parameters and possible errors in the appropriate equations in the literature to reality. Therefore, a simulation of a photovoltaic panel was proposed through mathematical equations that were adjusted according to the data of local radiation. The results have presented equations that provide real answers to the user and may assist in the design of these systems, once calculated that the maximum power limit ensures a supply of energy generated. This real sizing helps establishing the possible applications of solar energy to the rural producer and informing the real possibilities of generating electricity from the sun.
Resumo:
Among studies focused on increasing soybean grain yield, the ones related to sowing process are the most significant. Considering that soybean has an epigeal emergence, it becomes difficult to hint at the length covered by hypocotyl up to soil surface, or the actual planting depth. This study aimed to find an indicator that allows the identification of an ideal soybean planting depth. For this purpose, two complementary assays has been carried out in a greenhouse. The first aimed to identify structures that could be indicators of seed planting depth, on a medium-textured soil from Campos Gerais region, in the state of Paraná, Brazil. Spring NK 8350 cultivar seeds were sown at five theoretical depths (1, 2, 3, 4 and 5 cm). As seedlings emerged, the “differentiation zone” and the “root curve” depths were measured. The second assay was the validation of the suggested indicators in assay 1 from two soils, one medium-textured and one clay-textured. For this assay, it was used BRS 232. Both the methodologies showed high correlation with the theoretical planting depth. Although their correlation coefficient values were close, the differentiation zone appeared to be the most efficient reference with less planting depth overestimation.
Resumo:
OBJETIVO: correlacionar as queixas de incontinência urinária de esforço e os resultados da aplicação do pad test de uma hora em mulheres na pré e pós-menopausa. MÉTODOS: estudo transversal, composto por 60 voluntárias na pós-menopausa, divididas em dois grupos: um com 34 mulheres com queixa de perda involuntária de urina aos esforços, outro com 26 mulheres sem queixas de perda de urina aos esforços. Há também a presença de um Grupo Controle composto por 15 mulheres na pré-menopausa, com ciclo menstrual normal e sem queixas urinárias. Todas as mulheres foram avaliadas quanto à clínica e laboratorialmente, e submetidas ao pad test por uma hora. A paciente foi considerada incontinente quando o peso do absorvente após o teste foi maior do que 1 g. Os resultados obtidos foram submetidos à estatística descritiva, ao teste paramétrico ANOVA, ao pós-teste de Turkey e à correlação de Pearson. RESULTADOS: todas as mulheres na pós-menopausa apresentaram incontinência urinária de esforço durante o pad test, tanto as que referiram perda urinária (4 g), como as sem perda urinária prévia (3,5 g). Nessas mulheres, observou-se uma forte correlação das perdas de urina com o tempo de menopausa (r=0,8; p<0,01) e com o índice de massa corpórea (IMC) (r=0,7; p= 0,01). As mulheres na pré-menopausa mantiveram-se continentes durante o pad test (0,4 g). CONCLUSÕES: os resultados obtidos com a aplicação do pad test de uma hora mostraram que todas as mulheres na pós-menopausa apresentavam incontinência urinária de esforço, inclusive aquelas que não apresentavam queixa de perda de urina aos esforços. Essa perda de urina correlaciona-se com o tempo de menopausa e com o IMC.