163 resultados para Aprendizaje semi-presencial usando TICs


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A demonstractive experiment was proposed in order to verify students' habilities in recognizing the presence and nature of ions in solutions, before and after their passage through ion-exchange columns. The students have no previous contact with ion-exchange resins, so they must deduce how they work and explain the experimental facts. The performance of classes, at different stages of learning, is compared and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nickel, palladium and platinum micro-crystals were dispersed in films covering a vitreous carbon plate electrode by ion exchange followed by electroreduction of their ions. These modified electrodes were used in the electrocatalytic hydrogenation of several substrates of different classes and their efficiency is reported. A comparison among them was performed based on the structural characteristics of the metals. A modified electrode containing platinum showed to be more efficient than a palladium modified electrode and the one of nickel was the less efficient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of synthetic zeolites on stabilizing Zn-contaminated soil using 0.01 mol L-1 CaCl2 leaching solution in batch experiments was investigated. The zeolites were synthesized from coal ash by hydrothermal treatment with alkaline solution. The additive enhanced the sorption capacity of the soil and reduced leaching. Zinc leaching was reduced by more than 80% using a minimum of 10% additive. The higher cation exchange capacity of the zeolite/soil mixtures and higher pH were responsible for stabilizing Zn in soil. The poly(2-aminobenzenesulfonic acid)-coated mercury thin-film electrode was used for the determination of zinc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the preparation of the xerogel anilinepropylsilica is reported. The ability of the xerogel for extracting Al(III), Cr(III) and Fe(III) from ethanol was investigated at 25 ºC. The xerogel adsorption capacities were obtained from the adsorption isotherms by using the batch method. Flame atomic absorption spectrometry (FAAS) was used to estimate the concentration of metal ions in solution. The adsorption affinity follows the series Cr(III) > Fe(III) > Al(III) and the maximum adsorption capacities of the metal ions were 0.61, 0.52 and 0.43 mmol g-1, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this paper is the development of simple strategies to teach basic concepts of atomic spectrometry. Metals present in samples found in the daily lives of students are determined by flame atomic emission spectrometry (FAES). FAES is an accurate, precise, and inexpensive analytical method often used for determining sodium, potassium, lithium, and calcium. Historical aspects and their contextualization for students are also presented and experiments with samples that do not require pre-treatment are described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes a simple, fast and inexpensive method to determine As in natural waters, using X-ray fluorescence. 50 µL of each sample containing 100 mg L-1 of yttrium as internal standard were deposited over a 2.5 µm thickness MylarTM film. The samples were dried at 50 °C for 2 h. X-ray spectra were obtained using an EDXRF apparatus. The accuracy was determined by analyte addition/recovery and by comparison with Hydride Generation Atomic Absorption Spectrometry (HG AAS). A recovery of about 100% was obtained and the results were in good agreement with HG AAS. The method showed a relative standard deviation of 6.8% and a detection limit of 10.5 µg L-1 of As.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The total synthesis of sulfadiazine and silver sulfadiazine from readily available starting materials was adapted to semi-micro laboratory scale and is proposed as an experiment in drug synthesis for undergraduate courses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work illustrates the modeling procedure for a solvent mixture using the simplex- centroid approach. The selected experiment was the optimization of the peak current observed in the direct determination of nickel by anodic stripping voltammetry (ASV) in a solvent mixture composed of N,N-dimethylformamide, ethanol and water. The text is presented in a tutorial way, showing in detail the several steps which must be followed in such a process. Since not all possible mixtures lead to a measurable instrumental response, pseudocomponents had to be used to rescale the experimental design. This also allows to show how to apply this tool, usually troublesome for non-specialists in mixture modeling procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ONIOM method was used to calculate the proton affinities (PA) of n-alkylamines (CnH2n+1NH2, n = 3 to 6, 8, 10, 12, 14, 16 and 18). The calculations were carried out at several levels (HF, MP2, B3LYP, QCISD(T), ...) using Pople basis sets and at the QCISD(T) level using basis sets developed by the generator coordinate method (GCM) and adapted to effective core potentials. PAs were also obtained through the GCM and high level methods, like ONIOM[QCISD(T)/6-31+G(2df,p):MP2/6-31G+G(d,p))//ONIOM[MP2/6-31+G(d,p):HF/6-31G]. The average error using the GCM, with respect to experimental data, was 3.4 kJ mol-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the study was to observe eletrogenerated chemiluminescence (ECL) of luminol using different materials as electrodes such as wires, nails, coins, razor blades, etc. Based on the experimental observations and the mechanisms proposed in the literature, students should be capable of analyzing their results in order to understand the phenomena studied. Students could then elaborate a mechanism of action consistent with the experimental results which could rationalize the formation of intermediates in the reaction and the dependence of ECL on solution pH in addition to other points of interest

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper focuses: (i) the development of a measurement technique for the determination of atmospheric C2-C6 hydrocarbons with sampling in canisters and analysis by gas chromatography/flame ionisation detector (GC/FID), (ii) the improvement of an existent adsorption-sampling technique with Tenax TA tubes for the determination of C6-C11 hydrocarbons and analysis by GC/FID after thermal desorption and cryogenic concentration, (iii) the identification of compounds present in ambient air by gas chromatography/mass spectrometry (GC/MS) for both canister and Tenax samples, (iv) a program of interlaboratorial comparison for quality control of C2-C11 analyses, and (v) the seasonal characterisation of ambient air C2-C11 hydrocarbons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zeolitic material was synthesized from coal fly ashes (baghouse filter fly ash and cyclone filter fly ash) by hydrothermal alkaline activation. The potential application of the zeolitic product for decontamination of waters from acid mine drainage was evaluated. The results showed that a dose of 30 g L-1 of zeolitic material allowed the water to reach acceptable quality levels after treatment. Both precipitation and cation-exchange processes accounted for the reduction in the pollutant concentration in the treated waters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biosensors were developed by immobilization of gilo (Solanum gilo) enzymatic extract on chitosan biopolymers using three different procedures: glutaraldehyde, carbodiimide/glutaraldehyde and epichlorohydrin/glutaraldehyde. The best biosensor performance was obtained after the immobilization of peroxidase on chitosan with epichlorohydrin/glutaraldehyde. Linear analytical curves for hydroquinone concentrations from 2.5x10-4 to 4.5x10-3 mol L-1 with a detection limit of 2.0x10-6 mol L-1 and recovery of hydroquinone ranging from 95.1 to 105% were obtained. The relative standard deviation was < 1.0 % for a solution of 3.0x10-4 mol L-1 hydroquinone and 2.0x10-3 mol L-1 hydrogen peroxide in 0.1 mol L-1 phosphate buffer solution at pH 7.0 (n=8). The lifetime of this biosensor was 6 months (at least 300 determinations).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of residues of the major groups of pesticides (organohalogen, organophosphorous, pyrethroids and organonitrogen) in representative samples of honey produced in Bauru (state of São Paulo, Brazil) was investigated from 1999 through2004. A multiresidue method was applied to honey samples to determine 48 pesticides with recoveries ranging from 76 to 95%. The limits of detection found were lower than 10 µg/kg for GC-MS-SIM. The results indicated that most pesticides found in the samples belonged to the organohalogen and organonitrogen groups. Residues of malathion were detected in almost all of the samples in high concentration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple method was proposed for determination of paracetamol and ibuprofen in tablets, based on UV measurements and partial least squares. The procedure was performed at pH 10.5, in the concentration ranges 3.00-15.00 µg ml-1 (paracetamol) and 2.40-12.00 µg ml-1 (ibuprofen). The model was able to predict paracetamol and ibuprofen in synthetic mixtures with root mean squares errors of prediction of 0.12 and 0.17 µg ml-1, respectively. Figures of merit (sensitivity, limit of detection and precision) were also estimated. The results achieved for the determination of these drugs in pharmaceutical formulations were in agreement with label claims and verified by HPLC.