96 resultados para UV-VIS spectrophotometry


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A spectrophotometric method was proposed for Ni(II) determination in alloys using a dopa-semiquinone (L-1) to form [Ni(II)(L1-)3]1-, ε = 9.3 x 10³ L mol-1 cm-1. The optimal conditions for the determination were: wavelength 590 nm, temperature 25 °C, reaction time 45 min and pH 7.5. The Beer's law was obeyed for nickel from 3.33 x 10-5 to 1.78 x 10-4 mol L-1. The method was applied to complex samples, such as inox, nickel-titanium and cobalt-chromium alloys. A study of the potential interferents revealed that Mn was the major interferent. The limit of detection and quantification were 2.88 x 10-5 mol L-1 and 3.06 x 10-5 mol L-1, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Spectrophotometry is one of the most widespread analytical techniques due to its simplicity, reliability, and low-cost instrumentation for both direct measurements and coupled to other techniques or processes such as chromatography, electrophoresis and flow analysis. However, the application is often limited by sensitivity. This article describes some advances that greatly improve the performance of spectrophotometric measurements, especially in order to increase sensitivity, including the employment of liquid-core waveguides and solid-phase spectrophotometry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An UV-Vis spectrophotometry analytical method for quantifying Efavirenz was developed and validated as an alternative to replace the HPLC current method. The report method presents sample concentration of 10 μg mL-1, dissolved in a solution ethanol:water (60:40, v/v), economic and technically adequate for the purpose adopted. The results and the statistical treated proved that the method being considered an precise and accurate analytical low cost alternative for laboratory routine. The adaptability of this method in product and other analytical methods development has been challenged by mathematical calculation of drug extinction coefficient in water and methanol and practical experiments, showing interesting results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Caesalpinia peltophoroides is a domesticated tree found in Brazil. It was necessary to develop an analytical method to determine the content of total polyphenols (TP) in this herbal drug. The pre-analytical method was standardized for analysis time, wavelength, and the best standard to use. The optimum conditions were: pyrogallol, 760 nm, and 30 min respectively. Under these conditions, validation by UV/Vis spectrophotometry proved to be reliable for TP of the crude extract and semipurified fractions from C. peltophoroides. Standardization is required for every herbal drug, and this method proved to be linear, precise, accurate, reproducible, robust, and easy to perform.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This review presents the evolution of simultaneous multicomponent analysis by absorption spectrophotometry in the ultraviolet and visual regions in terms of some qualitative and quantitative analysis techniques, otimization methods, as well as applications and modern trends.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Foram caracterizados fisico-quimicamente ácidos húmicos, obtidos de composto de resíduos sólidos urbanos (AH-CRSU) e de lodo de estação de tratamento de esgoto (AH-LETE), ambos produzidos na cidade do Rio de Janeiro, por meio da análise da composição elementar, acidez total, de dados espectroscópicos (UV-Vis; IV, RMN de 13C-CP/MAS) e microscopia eletrônica de varredura (MEV). A análise das características estruturais revelou diferenças entre os AHs estudados. A presença de sistemas aromáticos foi observada por meio da espectroscopia de UV-Vis, indicando sistemas mais substituídos nos AH-LETE. A espectroscopia na região do infravermelho (IV) mostrou a presença de estruturas alifáticas nos AHs e maior complexidade nos sinais de absorção devida a polissacarídeos nos AH-CRSU. Além disso, foram observados grupos OH, COOH, COO-, CO2NH2, e confirmada a presença de sistemas aromáticos. Com a análise de RMN de 13C-CP/MAS, foi possível verificar as diferenças quantitativas nos diferentes tipos de carbono. Os AH-LETE apresentaram maior quantidade de grupos aromáticos e de COOH. A análise de RMN de 13C-CP/MAS também mostrou presença de polissacarídeos, N em aminoácidos e grupamentos OCH3. O conjunto de propriedades avaliadas permitiu indicar que a fração ácidos húmicos dos resíduos é "do tipo" ou "análoga" aos ácidos húmicos de origem pedogênica.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, robust, versatile, high analytical frequency method was proposed to check if a sample of wine is within the range of standards set by the manufacturer, using the UV-VIS spectroscopy, multivariate analysis and a flow-batch analyzer. Two hundred and fifty-two samples of wines were analyzed. The results from the application of Hierachical Cluster Analysis (HCA) to the matrix of the data involving all samples show the formation of fifteen types of wine. A Soft Independent Modelling of Class Analogy (SIMCA) model was constructed and used to classify the samples of the overall forecast. As a result, it is observed that the prediction was performed with a success rate of 99.2% for a confidence level of 95%. This shows that the proposed methodology can be used as an effective tool for classifying of samples of wines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The post-preparative size-selective precipitation technique was applied in CdTe and CdSe semiconductor nanocrystals prepared via colloidal route in water. The synthesis of CdTe and CdSe nanoparticles and the effect of the post-preparative size-selective precipitation have been characterized mainly by mean of ultraviolet and visible absorption spectroscopy (UV-Vis). It was demonstrated that the size-selective precipitation are able to isolate particles of different sizes and purify the nanoparticles as well.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A validation study of an UV spectrophotometric method was conducted for quantitative analysis of benznidazol (BZN) in a lipid. The analytical determinations were performed at 315 nm at 25 ºC. The emulsion components did not interfere on drug analyses, demonstrating the specificity of the methodology. A good linearity (r = 0.99995) and precision (RSD < 5.0%) for intra and inter-day studies, including the reproducibility test were observed. The accuracy ranged of 102.1 + 2.8 e 103.8 + 1.7%. The statistical analysis demonstrates a linear, precise, accurate and robust method for BZN quantification from the lipid emulsion system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports on a modification of the procedures originally described in the French Pharmacopoeia for the UV-visible spectrometric analysis of flavonoids, and proposes a validation of the method and its application in the determination of total flavonoids from sugarcane (Saccharum officinarum) leaves and vinasse. An analysis of precision and accuracy revealed a low relative standard deviation (< 5.0%) and a good recovery percentages (99.79 and 98.34%). A comparison of the spectrometric results against those obtained by high performance liquid chromatography (HPLC-UV) demonstrated complete compatibility between the modified French Pharmacopoeia (spectrometric) and HPLC-UV methods

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A statistical mixture-design technique was used to study the effects of different solvents and their mixtures on the yield, total polyphenol content, and antioxidant capacity of the crude extracts from the bark of Schinus terebinthifolius Raddi (Anacardiaceae). The experimental results and their response-surface models showed that ternary mixtures with equal portions of all the three solvents (water, ethanol and acetone) were better than the binary mixtures in generating crude extracts with the highest yield (22.04 ± 0.48%), total polyphenol content (29.39 ± 0.39%), and antioxidant capacity (6.38 ± 0.21). An analytical method was developed and validated for the determination of total polyphenols in the extracts. Optimal conditions for the various parameters in this analytical method, namely, the time for the chromophoric reaction to stabilize, wavelength of the absorption maxima to be monitored, the reference standard and the concentration of sodium carbonate were determined to be 5 min, 780 nm, pyrogallol, and 14.06% w v-1, respectively. UV-Vis spectrophotometric monitoring of the reaction under these conditions proved the method to be linear, specific, precise, accurate, reproducible, robust, and easy to perform.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A técnica de CLAE com detecção UV-Vis foi empregada na análise do teor de cocaína em amostras apreendidas de cocaína e crack. Uma fase móvel de acetonitrila/água (95:5v/v) possibilitou um sinal de pico para a cocaína em 3,5 minutos. O sinal espectrofotométrico otimizado foi obtido em um comprimento de onda de 224 nm. A curva analítica de 1,0 a 40,0 ppm para cocaína foi obtida, exibindo um coeficiente de correlação linear de 0,9989, com limites de detecção e quantificação de 0,75 e 3,78 ppm, respectivamente. Esta metodologia foi aplicada na dosagem de amostras confiscadas de cocaína e crack no Laboratório de Polícia Científica de Ribeirão Preto-SP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Os corantes sintéticos são usualmente adicionados a alimentos industrializados para conferir e restaurar a cor obtendo-se a qualidade estética desejada. Em função destes aspectos e do potencial toxicológico que alguns corantes podem apresentar, o controle de qualidade destes compostos é de fundamental importância. Neste trabalho, foi estudado o potencial das metodologias matemáticas como o princípio da aditividade, espectrofotometria derivativa e técnica multivariada (Regressão por Mínimos Quadrados Parciais - PLSR) na determinação simultânea de dois corantes alimentícios: Amarelo Crepúsculo (AC) e Amarelo Tartrazina (AT), extraídos com lã natural. Estas metodologias foram avaliadas e comparadas em função das suas capacidades de previsão, sendo que o modelo PLSR otimizado (faixa espectral de 305 a 645 nm, empregando-se 1ª derivada como transformação dos dados e 2 componentes principais) apresentou o menor valor de Raiz Quadrada da Soma dos Erros de Previsão (RMSEP) (AT = 0,191 e AC = 0,102). A faixa de concentração estudada foi de 1,0 a 16,0 mg.L-1 para AC e de 2,0 a 22,0 mg.L-1 para AT. O conjunto de validação externa apresentou erros relativos médios de 1,97% para AC e 1,39% para AT. A aplicação desta metodologia em amostras reais mostrou que em todas as amostras analisadas as concentrações destes corantes estavam de acordo com os limites estabelecidos pela legislação brasileira

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple chemical method has been developed to quantify the silanol groups (º Si-OH) in silica as well as in coated chromatographic supports for use in packed - column Gas Chromatography. After adsorption of 10 mg/mL methylene blue, centrifuging action and filtration, the absorbance of the solution was inversely proportional to the silanol quantity. The difference between the absorbance of the pure solution and that of the solid - free filtrate was related to the silica weight, yielding a quantitative analysis of these groups.