83 resultados para path sampling

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a generalized framework for gradient-domain Metropolis rendering, and introduce three techniques to reduce sampling artifacts and variance. The first one is a heuristic weighting strategy that combines several sampling techniques to avoid outliers. The second one is an improved mapping to generate offset paths required for computing gradients. Here we leverage the properties of manifold walks in path space to cancel out singularities. Finally, the third technique introduces generalized screen space gradient kernels. This approach aligns the gradient kernels with image structures such as texture edges and geometric discontinuities to obtain sparser gradients than with the conventional gradient kernel. We implement our framework on top of an existing Metropolis sampler, and we demonstrate significant improvements in visual and numerical quality of our results compared to previous work.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We introduce gradient-domain rendering for Monte Carlo image synthesis.While previous gradient-domain Metropolis Light Transport sought to distribute more samples in areas of high gradients, we show, in contrast, that estimating image gradients is also possible using standard (non-Metropolis) Monte Carlo algorithms, and furthermore, that even without changing the sample distribution, this often leads to significant error reduction. This broadens the applicability of gradient rendering considerably. To gain insight into the conditions under which gradient-domain sampling is beneficial, we present a frequency analysis that compares Monte Carlo sampling of gradients followed by Poisson reconstruction to traditional Monte Carlo sampling. Finally, we describe Gradient-Domain Path Tracing (G-PT), a relatively simple modification of the standard path tracing algorithm that can yield far superior results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gradient-domain path tracing has recently been introduced as an efficient realistic image synthesis algorithm. This paper introduces a bidirectional gradient-domain sampler that outperforms traditional bidirectional path tracing often by a factor of two to five in terms of squared error at equal render time. It also improves over unidirectional gradient-domain path tracing in challenging visibility conditions, similarly as conventional bidirectional path tracing improves over its unidirectional counterpart. Our algorithm leverages a novel multiple importance sampling technique and an efficient implementation of a high-quality shift mapping suitable for bidirectional path tracing. We demonstrate the versatility of our approach in several challenging light transport scenarios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In contact shots, all the materials emerging from the muzzle (combustion gases, soot, powder grains, and metals from the primer) will be driven into the depth of the entrance wound and the following sections of the bullet track. The so-called "pocket" ("powder cavity") under the skin containing soot and gunpowder particles is regarded as a significant indicator of a contact entrance wound since one would expect that the quantity of GSR deposited along the bullet's path rapidly declines towards the exit hole. Nevertheless, experience has shown that soot, powder particles, and carboxyhemoglobin may be found not only in the initial part of the wound channel, but also far away from the entrance and even at the exit. In order to investigate the propagation of GSRs under standardized conditions, contact test shots were fired against composite models of pig skin and 25-cm-long gelatin blocks using 9-mm Luger pistol cartridges with two different primers (Sinoxid® and Sintox®). Subsequently, 1-cm-thick layers of the gelatin blocks were examined as to their primer element contents (lead, barium, and antimony as discharge residues of Sinoxid® as well as zinc and titanium from Sintox®) by means of X-ray fluorescence spectroscopy. As expected, the highest element concentrations were found in the initial parts of the bullet tracks, but also the distal sections contained detectable amounts of the respective primer elements. The same was true for amorphous soot and unburned/partly burned powder particles, which could be demonstrated even at the exit site. With the help of a high-speed motion camera it was shown that for a short time the temporary cavitation extends from the entrance to the exit thus facilitating the unlimited spread of discharge residues along the whole bullet path.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During a two-stage revision for prosthetic joint infections (PJI), joint aspirations, open tissue sampling and serum inflammatory markers are performed before re-implantation to exclude ongoing silent infection. We investigated the performance of these diagnostic procedures on the risk of recurrence of PJI among asymptomatic patients undergoing a two-stage revision. A total of 62 PJI were found in 58 patients. All patients had intra-operative surgical exploration during re-implantation, and 48 of them had intra-operative microbiological swabs. Additionally, 18 joint aspirations and one open biopsy were performed before second-stage reimplantation. Recurrence or persistence of PJI occurred in 12 cases with a mean delay of 218 days after re-implantation, but only four pre- or intraoperative invasive joint samples had grown a pathogen in cultures. In at least seven recurrent PJIs (58%), patients had a normal C-reactive protein (CRP, < 10 mg/l) level before re-implantation. The sensitivity, specificity, positive predictive and negative predictive values of pre-operative invasive joint aspiration and CRP for the prediction of PJI recurrence was 0.58, 0.88, 0.5, 0.84 and 0.17, 0.81, 0.13, 0.86, respectively. As a conclusion, pre-operative joint aspiration, intraoperative bacterial sampling, surgical exploration and serum inflammatory markers are poor predictors of PJI recurrence. The onset of reinfection usually occurs far later than reimplantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional MRI may still be an inaccurate method for the non-invasive detection of a microadenoma in adrenocorticotropin (ACTH)-dependent Cushing's syndrome (CS). Bilateral inferior petrosal sinus sampling (BIPSS) with ovine corticotropin-releasing hormone (oCRH) stimulation is an invasive, but accurate, intervention in the diagnostic armamentarium surrounding CS. Until now, there is a continuous controversial debate regarding lateralization data in detecting a microadenoma. Using BIPSS, we evaluated whether a highly selective placement of microcatheters without diversion of venous outflow might improve detection of pituitary microadenoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analysis of samplings from periodontal pockets is important in the diagnosis and therapy of periodontitis. In this study, three different sampling techniques were compared to determine whether one method yielded samples suitable for the reproducible and simultaneous determination of bacterial load, cytokines, neutrophil elastase, and arginine-specific gingipains (Rgps). Rgps are an important virulence factor of Porphyromonas gingivalis, the exact concentration of which in gingival crevicular fluid (GCF) has not been quantified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate the inhomogeneity of radiofrequency fields at higher field strengths that can interfere with established volumetric methods, in particular for the determination of visceral (VAT) and subcutaneous adipose tissue (SCAT). A versatile, interactive sparse sampling (VISS) method is proposed to determine VAT, SCAT, and also total body volume (TBV).