118 resultados para balloon catheter

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Portal vein embolization (PVE) may be performed before hemihepatectomy to increase the volume of future liver remnant (FLR) and to reduce the risk of postoperative liver insufficiency. We report the case of a 71-year-old patient with hilar cholangiocarcinoma undergoing PVE with access from the right portal vein using a mixture of n-butyl-2-cyanoacrylate and ethiodized oil. During the procedure, nontarget embolization of the left portal vein occurred. An aspiration maneuver of the polymerized plug failed; however, the embolus obstructing portal venous flow in the FLR was successfully relocated into the right portal vein while carefully bypassing the plug with a balloon catheter, inflating the balloon, and pulling the plug into the main right portal vein.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Currently, only anecdotal information exists on the presentation and outcome of coronary arterial injury after ablation procedures. METHODS AND RESULTS: Four patients who sustained coronary artery injury of a cohort of patients undergoing 4655 consecutive ablation procedures (0.09%) are described. The patients' mean age was 45+/-11 years, and 1.8+/-0.5 prior ablation attempts had been unsuccessful. Coronary injury occurred from epicardial ventricular tachycardia ablation in 2 patients (irrigated radiofrequency ablation in one and cryoablation in the other) and ablation within the middle cardiac vein with irrigated radiofrequency in 2 patients. All involved branches of the right coronary artery. Acute occlusion presenting with ST-segment elevation immediately after ablation was recognized during the procedure in 2 cases. Occlusion failed to respond to nitroglycerin or balloon dilation, and stenting was required in both cases. Acute myocardial infarction occurred 2 weeks after epicardial ablation as a result of occlusion of a right ventricular branch of the right coronary artery giving rise to the posterior descending coronary artery in 1 patient. A moderate asymptomatic stenosis was seen on angiography after epicardial cryoablation in 1 patient. All patients recovered and remained asymptomatic from the coronary injury and arrhythmias during 37+/-53 months of follow-up. CONCLUSIONS: Coronary arterial injury after ablation procedures is rare. It may present acutely or several weeks after an ablation procedure. Acute occlusion appears to require coronary stenting. Unanticipated anatomic variations can predispose to coronary injury.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently developed technologies allow aortic valve implantation off-pump in a beating heart. In this procedure, the native, stenotic aortic valve is not removed, but simply crushed by a pressure balloon mounted on a percutaneous catheter. Removal of the native aortic cusps before valve replacement may reduce the incidence of annular or cuspal calcium embolization and late perivalvular leaks and increase implantable valve size. However, a temporary valve system in the ascending aorta may be necessary to maintain hemodynamic stability by reducing acute aortic regurgitation and left ventricular volume overload. This study evaluates the hemodynamic effects of a wire-mounted, monoleaflet, temporary valve apparatus in a mechanical cardiovascular simulator. Aortic flow, systemic pressure and left ventricular pressure were continuously monitored. An intraluminal camera obtained real-time proximal and distal images of the valve in operation. Insertion of the parachute valve in the simulator increased diastolic pressure from 7 to 38 mm Hg. Cardiac output increased from 2.08 to 4.66 L/min and regurgitant volume decreased from 65 to 23 mL. In conclusion, placement of a temporary valve in the ascending aorta may help maintain hemodynamic stability and improve off-pump aortic valve replacement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Venous angioplasty with stenting of iliac veins is an important treatment option for patients suffering from post-thrombotic syndrome due to chronic venous obstruction. Interventional treatment of a chronically occluded vena cava, however, is challenging and often associated with failure. We describe a case of a chronic total occlusion of the entire inferior vena cava that was successfully recanalized using bidirectional wire access and a balloon puncture by a re-entry catheter to establish patency of the inferior vena cava.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Arrhythmia origin in close proximity to the phrenic nerve (PN) can hinder successful catheter ablation. We describe our approach with epicardial PN displacement in such instances. METHODS AND RESULTS PN displacement via percutaneous pericardial access was attempted in 13 patients (age 49±16 years, 9 females) with either atrial tachycardia (6 patients) or atrial fibrillation triggered from a superior vena cava focus (1 patient) adjacent to the right PN or epicardial ventricular tachycardia origin adjacent to the left PN (6 patients). An epicardially placed steerable sheath/4 mm-catheter combination (5 patients) or a vascular or an esophageal balloon (8 patients) was ultimately successful. Balloon placement was often difficult requiring manipulation via a steerable sheath. In 2 ventricular tachycardia cases, absence of PN capture was achieved only once the balloon was directly over the ablation catheter. In 3 atrial tachycardia patients, PN displacement was not possible with a balloon; however, a steerable sheath/catheter combination was ultimately successful. PN displacement allowed acute abolishment of all targeted arrhythmias. No PN injury occurred acutely or in follow up. Two patients developed acute complications (pleuro-pericardial fistula 1 and pericardial bleeding 1). Survival free of target arrhythmia was achieved in all atrial tachycardia patients; however, a nontargeted ventricular tachycardia recurred in 1 patient at a median of 13 months' follow up. CONCLUSIONS Arrhythmias originating in close proximity to the PN can be targeted successfully with PN displacement with an epicardially placed steerable sheath/catheter combination, or balloon, but this strategy can be difficult to implement. Better tools for phrenic nerve protection are desirable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Swiss Federal Office of Public Health demanded a nationwide health technology assessment registry for cervical and lumbar total disc arthroplasty and for balloon kyphoplasty (BKP) to make a decision about reimbursement of these interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ventricular tachycardia (VT) late after myocardial infarction is an important contributor to morbidity and mortality. This prospective multicenter study assessed the efficacy and safety of electroanatomical mapping in combination with open-saline irrigated ablation technology for ablation of chronic recurrent mappable and unmappable VT in remote myocardial infarction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The latest-generation Amplatzer vascular plug (AVP), the AVP 4, is designed for embolization of smaller vessels without a sheath or guiding catheter. This study evaluated the AVP 4 in peripheral vascular embolization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endovascular treatment is an increasingly used therapeutic option in patients with chronic atherosclerotic occlusive mesenteric disease. Purpose of this study was evaluation of patency and mortality in patients treated with visceral artery percutaneous transluminal angioplasty (PTA) or stenting including follow-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vertebroplasty and kyphoplasty are well-established minimally invasive treatment options for compression fractures of osteoporotic vertebral bodies. Possible procedural disadvantages, however, include incomplete fracture reduction or a significant loss of reduction after balloon tamp deflation, prior to cement injection. A new procedure called "vertebral body stenting" (VBS) was tested in vitro and compared to kyphoplasty. VBS uses a specially designed catheter-mounted stent which can be implanted and expanded inside the vertebral body. As much as 24 fresh frozen human cadaveric vertebral bodies (T11-L5) were utilized. After creating typical compression fractures, the vertebral bodies were reduced by kyphoplasty (n = 12) or by VBS (n = 12) and then stabilized with PMMA bone cement. Each step of the procedure was performed under fluoroscopic control and analysed quantitatively. Finally, static and dynamic biomechanical tests were performed. A complete initial reduction of the fractured vertebral body height was achieved by both systems. There was a significant loss of reduction after balloon deflation in kyphoplasty compared to VBS, and a significant total height gain by VBS (mean +/- SD in %, p < 0.05, demonstrated by: anterior height loss after deflation in relation to preoperative height [kyphoplasty: 11.7 +/- 6.2; VBS: 3.7 +/- 3.8], and total anterior height gain [kyphoplasty: 8.0 +/- 9.4; VBS: 13.3 +/- 7.6]). Biomechanical tests showed no significant stiffness and failure load differences between systems. VBS is an innovative technique which allows for the possibly complete reduction of vertebral compression fractures and helps maintain the restored height by means of a stent. The height loss after balloon deflation is significantly decreased by using VBS compared to kyphoplasty, thus offering a new promising option for vertebral augmentation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In patients with ventricular tachycardia (VT) and a history of myocardial infarction, intervention with an implantable cardioverter defibrillator (ICD) can prevent sudden cardiac death and thereby reduce total mortality. However, ICD shocks are painful and do not provide complete protection against sudden cardiac death. We assessed the potential benefit of catheter ablation before implantation of a cardioverter defibrillator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnostic coronary balloon occlusion (CBO) is mandatory for collateral function assessment, during angioscopy and optical coherence imaging, and when using certain coronary protection devices against emboli. Thus far, the safety of diagnostic CBO regarding procedural and long-term complications in normal coronary arteries has not been studied. In 316 patients, diagnostic CBO was performed for collateral function measurement in 426 angiographically normal vessels. The angioplasty balloon was inflated for 60 to 120 seconds using inflation pressures of 1 to 3 atm, followed by control angiography during and after CBO. Patients were divided into groups with entirely normal (n = 133) and partially normal (n = 183) vessels. Primary end points were procedural and long-term complications. De novo stenosis development was assessed by quantitative coronary angiography in 35% of the patients. Secondary end points were cardiac events at 5 years of follow-up. Procedural complications occurred in 1 patient (0.2%). In 150 repeat angiographic procedures in 92 patients (follow-up duration 10 +/- 15 months), quantitative coronary angiography revealed no difference in percentage diameter narrowing between baseline and follow-up (4.1% vs 3.9%, p = 0.69). During follow-up periods of 14 and 72 months, respectively, a new stenotic lesion was detected in 1 patient in each group (1.3%). Major cardiac events and percutaneous coronary intervention for stable angina were less frequent in the group with entirely normal than with partially normal vessels (0.8% vs 5.5%, p = 0.02, and 0.8% vs 18%, p <0.0001). In conclusion, low-inflation pressure diagnostic CBO in angiographically normal coronary arteries bears a minimal risk for procedural and long-term complications and can therefore be regarded as a safe procedure.