Epicardial phrenic nerve displacement during catheter ablation of atrial and ventricular arrhythmias: procedural experience and outcomes.
Data(s) |
01/08/2015
|
---|---|
Resumo |
BACKGROUND Arrhythmia origin in close proximity to the phrenic nerve (PN) can hinder successful catheter ablation. We describe our approach with epicardial PN displacement in such instances. METHODS AND RESULTS PN displacement via percutaneous pericardial access was attempted in 13 patients (age 49±16 years, 9 females) with either atrial tachycardia (6 patients) or atrial fibrillation triggered from a superior vena cava focus (1 patient) adjacent to the right PN or epicardial ventricular tachycardia origin adjacent to the left PN (6 patients). An epicardially placed steerable sheath/4 mm-catheter combination (5 patients) or a vascular or an esophageal balloon (8 patients) was ultimately successful. Balloon placement was often difficult requiring manipulation via a steerable sheath. In 2 ventricular tachycardia cases, absence of PN capture was achieved only once the balloon was directly over the ablation catheter. In 3 atrial tachycardia patients, PN displacement was not possible with a balloon; however, a steerable sheath/catheter combination was ultimately successful. PN displacement allowed acute abolishment of all targeted arrhythmias. No PN injury occurred acutely or in follow up. Two patients developed acute complications (pleuro-pericardial fistula 1 and pericardial bleeding 1). Survival free of target arrhythmia was achieved in all atrial tachycardia patients; however, a nontargeted ventricular tachycardia recurred in 1 patient at a median of 13 months' follow up. CONCLUSIONS Arrhythmias originating in close proximity to the PN can be targeted successfully with PN displacement with an epicardially placed steerable sheath/catheter combination, or balloon, but this strategy can be difficult to implement. Better tools for phrenic nerve protection are desirable. |
Formato |
application/pdf |
Identificador |
http://boris.unibe.ch/83888/1/896.full.pdf Kumar, Saurabh; Barbhaiya, Chirag R; Baldinger, Samuel Hannes; Koplan, Bruce A; Maytin, Melanie; Epstein, Laurence M; John, Roy M; Michaud, Gregory F; Tedrow, Usha B; Stevenson, William G (2015). Epicardial phrenic nerve displacement during catheter ablation of atrial and ventricular arrhythmias: procedural experience and outcomes. Circulation. Arrhythmia and electrophysiology, 8(4), pp. 896-904. Lippincott Williams & Wilkins 10.1161/CIRCEP.115.002818 <http://dx.doi.org/10.1161/CIRCEP.115.002818> doi:10.7892/boris.83888 info:doi:10.1161/CIRCEP.115.002818 info:pmid:25963395 urn:issn:1941-3084 |
Idioma(s) |
eng |
Publicador |
Lippincott Williams & Wilkins |
Relação |
http://boris.unibe.ch/83888/ |
Direitos |
info:eu-repo/semantics/restrictedAccess |
Fonte |
Kumar, Saurabh; Barbhaiya, Chirag R; Baldinger, Samuel Hannes; Koplan, Bruce A; Maytin, Melanie; Epstein, Laurence M; John, Roy M; Michaud, Gregory F; Tedrow, Usha B; Stevenson, William G (2015). Epicardial phrenic nerve displacement during catheter ablation of atrial and ventricular arrhythmias: procedural experience and outcomes. Circulation. Arrhythmia and electrophysiology, 8(4), pp. 896-904. Lippincott Williams & Wilkins 10.1161/CIRCEP.115.002818 <http://dx.doi.org/10.1161/CIRCEP.115.002818> |
Palavras-Chave | #610 Medicine & health |
Tipo |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion PeerReviewed |