In Vitro Testing of a Temporary Catheter-Based Aortic "Parachute" Valve


Autoria(s): Vandenberghe, Stijn; Salizzoni, Stefano; Bajona, Pietro; Zehr, Kenton J; Speziali, Giovanni
Data(s)

2008

Resumo

Recently developed technologies allow aortic valve implantation off-pump in a beating heart. In this procedure, the native, stenotic aortic valve is not removed, but simply crushed by a pressure balloon mounted on a percutaneous catheter. Removal of the native aortic cusps before valve replacement may reduce the incidence of annular or cuspal calcium embolization and late perivalvular leaks and increase implantable valve size. However, a temporary valve system in the ascending aorta may be necessary to maintain hemodynamic stability by reducing acute aortic regurgitation and left ventricular volume overload. This study evaluates the hemodynamic effects of a wire-mounted, monoleaflet, temporary valve apparatus in a mechanical cardiovascular simulator. Aortic flow, systemic pressure and left ventricular pressure were continuously monitored. An intraluminal camera obtained real-time proximal and distal images of the valve in operation. Insertion of the parachute valve in the simulator increased diastolic pressure from 7 to 38 mm Hg. Cardiac output increased from 2.08 to 4.66 L/min and regurgitant volume decreased from 65 to 23 mL. In conclusion, placement of a temporary valve in the ascending aorta may help maintain hemodynamic stability and improve off-pump aortic valve replacement.

Formato

application/pdf

Identificador

http://boris.unibe.ch/50103/1/00002480-200811000-00003.pdf

Vandenberghe, Stijn; Salizzoni, Stefano; Bajona, Pietro; Zehr, Kenton J; Speziali, Giovanni (2008). In Vitro Testing of a Temporary Catheter-Based Aortic "Parachute" Valve. ASAIO journal, 54(6), pp. 574-577. Lippincott 10.1097/MAT.0b013e31818b3d93 <http://dx.doi.org/10.1097/MAT.0b013e31818b3d93>

doi:10.7892/boris.50103

info:doi:10.1097/MAT.0b013e31818b3d93

info:pmid:19033768

urn:issn:1058-2916

Idioma(s)

eng

Publicador

Lippincott

Relação

http://boris.unibe.ch/50103/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Vandenberghe, Stijn; Salizzoni, Stefano; Bajona, Pietro; Zehr, Kenton J; Speziali, Giovanni (2008). In Vitro Testing of a Temporary Catheter-Based Aortic "Parachute" Valve. ASAIO journal, 54(6), pp. 574-577. Lippincott 10.1097/MAT.0b013e31818b3d93 <http://dx.doi.org/10.1097/MAT.0b013e31818b3d93>

Palavras-Chave #610 Medicine & health
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed