10 resultados para MAMMOGRAPHY

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM To evaluate the diagnostic value (sensitivity, specificity) of positron emission mammography (PEM) in a single site non-interventional study using the maximum PEM uptake value (PUVmax). PATIENTS, METHODS In a singlesite, non-interventional study, 108 patients (107 women, 1 man) with a total of 151 suspected lesions were scanned with a PEM Flex Solo II (Naviscan) at 90 min p.i. with 3.5 MBq 18F-FDG per kg of body weight. In this ROI(region of interest)-based analysis, maximum PEM uptake value (PUV) was determined in lesions, tumours (PUVmaxtumour), benign lesions (PUVmaxnormal breast) and also in healthy tissues on the contralateral side (PUVmaxcontralateral breast). These values were compared and contrasted. In addition, the ratios of PUVmaxtumour / PUVmaxcontralateral breast and PUVmaxnormal breast / PUVmaxcontralateral breast were compared. The image data were interpreted independently by two experienced nuclear medicine physicians and compared with histology in cases of suspected carcinoma. RESULTS Based on a criteria of PUV>1.9, 31 out of 151 lesions in the patient cohort were found to be malignant (21%). A mean PUVmaxtumour of 3.78 ± 2.47 was identified in malignant tumours, while a mean PUVmaxnormal breast of 1.17 ± 0.37 was reported in the glandular tissue of the healthy breast, with the difference being statistically significant (p < 0.001). Similarly, the mean ratio between tumour and healthy glandular tissue in breast cancer patients (3.15 ± 1.58) was found to be significantly higher than the ratio for benign lesions (1.17 ± 0.41, p < 0.001). CONCLUSION PEM is capable of differentiating breast tumours from benign lesions with 100% sensitivity along with a high specificity of 96%, when a threshold of PUVmax >1.9 is applied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: A microangiographical technique is described, which allows visualization of small and capillary blood vessels and quantification of fasciocutaneous blood vessels by means of digital computer analysis in very small laboratory animals. MATERIALS AND METHODS: The left carotid artery of 20 nu/nu mice was cannulated (26 gauge) and a mixture of gelatin, bariumsulfate, and green ink was injected according to standardized protocol. Fasciocutaneous blood vessels were visualized by digital mammography and analyzed for vessel length and vessel surface area as standardized units [SU] by computer program. RESULTS: With the described microangiography method, fasciocutaneous blood vessels down to capillary size level can be clearly visualized. Regions of interest (ROIs) can be defined and the containing vascular network quantified. Comparable results may be obtained by calculating the microvascular area index (MAI) and the microvascular length index (MLI), related to the ROIs size. Identical ROIs showed a high reproducibility for measured [SU] < 0.01 +/- 0.0012%. CONCLUSION: Combining microsurgical techniques, pharmacological knowledge, and modern digital image technology, we were able to visualize small and capillary blood vessels even in small laboratory animals. By using our own computer analytical program, quantification of vessels was reliable, highly reproducible, and fast.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to assess the performance of a new motion correction algorithm. Twenty-five dynamic MR mammography (MRM) data sets and 25 contrast-enhanced three-dimensional peripheral MR angiographic (MRA) data sets which were affected by patient motion of varying severeness were selected retrospectively from routine examinations. Anonymized data were registered by a new experimental elastic motion correction algorithm. The algorithm works by computing a similarity measure for the two volumes that takes into account expected signal changes due to the presence of a contrast agent while penalizing other signal changes caused by patient motion. A conjugate gradient method is used to find the best possible set of motion parameters that maximizes the similarity measures across the entire volume. Images before and after correction were visually evaluated and scored by experienced radiologists with respect to reduction of motion, improvement of image quality, disappearance of existing lesions or creation of artifactual lesions. It was found that the correction improves image quality (76% for MRM and 96% for MRA) and diagnosability (60% for MRM and 96% for MRA).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Screening for malignant disease aims to reduce the population risk of impaired health due to the tumor in question. Screening does not only entail testing but covers all steps required to achieve the intended reduction in risk, from the appropriate information of the population to a suitable therapy. Screening tests are performed in individuals free or unaware of any symptoms associated with the tumor. An essential condition is a recognizable pathological abnormality, which occurs without symptoms and represents a pre-clinical, early stage of the tumor. Overdiagnosis and overtreatment have only recently been recognized as important problems of screening for malignant disease. Overdiagnosis is defined as a screening-detected tumor that would never have led to symptoms. In prostate-specific antigen (PSA) screening for prostate cancer 50 % - 70 % of screening-detected cancers represent such overdiagnoses. Similarly, in the case of mammography screening 20 % - 30 % of screening-detected breast cancers are overdiagnoses. The evaluation of screening interventions is often affected by biases such as healthy screenee effects or length and lead time bias. Randomized controlled trials are therefore needed to examine the efficacy and effectiveness of screening interventions and to define the rate of adverse outcomes such as unnecessary diagnostic evaluations, overdiagnosis and overtreatment. Unfortunately there is no independent Swiss body comparable to the National Screening Committee in the United Kingdom or the United States Preventive Services Task Force, which examines screening tests and programs and develops recommendations. Clearly defined goals, a central organization responsible for inviting eligible individuals, documentation and quality assurance and balanced information of the public are important attributes of successful screening programs. In Switzerland the establishment of such programs is hampered by the highly fragmented, Federal health system which allows patients to access specialists directly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nur wenige Vorsorgeuntersuchungen sind so umfassend in randomisiert-kon- trollierten Studien (RCTs) untersucht worden wie das Screening auf Brustkrebs mit Hilfe der Mammografie. Es liegen derzeit acht große randomisiert-kontrol- lierte Studien und mehrere Meta-Analysen vor. Letztere kommen mehrheitlich zum Schluss, dass sich die Brustkrebssterblichkeit durch Mammografie-Screening um etwa 20 % senken lässt. Dies bedeutet im Schweizer Kontext, dass etwa 1 von 1'000 Frauen weniger an Brustkrebs stirbt, wenn Frauen ab dem 50. Lebensjahr zehn Jahre lang gescreent werden. Andererseits führt das Screening auch zu Überdiagnosen und Übertherapien. So nimmt die Zahl der Brustkrebsdiagnosen um etwa 20 % zu, was zu einer entsprechenden Zunahme an chirurgischen Ein- griffen, Strahlen- und Chemotherapien führt. Über zehn Jahre gerechnet, erhal- ten etwa 4 von 1'000 Frauen eine Brustkrebsdiagnose, die sie ohne Screening nicht erhalten hätten. Etwa 200 von 1'000 Frauen sind im Verlaufe von zehn Jahren (fünf Screening-Runden) mit abklärungsbedürftigen Befunden konfron- tiert, wobei es sich dabei mehrheitlich um falsch positive Befunde handelt. Gleichzeitig werden auch mit einem Screening-Programm 20 bis 30 % der Brust- krebse nicht im Screening erfasst. Die Information der Bevölkerung bezüglich des Mammografie-Screenings ist derzeit noch mangelhaft. Dies führt dazu, dass der mögliche Nutzen von den betroffenen Frauen überschätzt und der Schaden unterschätzt wird. Die Aufklärung der Bevölkerung im Hinblick auf Nutzen und Risiken des Mammografie-Screenings muss daher verbessert werden, denn Frau- en haben einen Anspruch auf evidenzbasierte Informationen und eine „infor- mierte Entscheidung“.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The aim of this study was to evaluate imaging-based response to standardized neoadjuvant chemotherapy (NACT) regimen by dynamic contrast-enhanced magnetic resonance mammography (DCE-MRM), whereas MR images were analyzed by an automatic computer-assisted diagnosis (CAD) system in comparison to visual evaluation. MRI findings were correlated with histopathologic response to NACT and also with the occurrence of metastases in a follow-up analysis. PATIENTS AND METHODS Fifty-four patients with invasive ductal breast carcinomas received two identical MRI examinations (before and after NACT; 1.5T, contrast medium gadoteric acid). Pre-therapeutic images were compared with post-therapeutic examinations by CAD and two blinded human observers, considering morphologic and dynamic MRI parameters as well as tumor size measurements. Imaging-assessed response to NACT was compared with histopathologically verified response. All clinical, histopathologic, and DCE-MRM parameters were correlated with the occurrence of distant metastases. RESULTS Initial and post-initial dynamic parameters significantly changed between pre- and post-therapeutic DCE-MRM. Visually evaluated DCE-MRM revealed sensitivity of 85.7%, specificity of 91.7%, and diagnostic accuracy of 87.0% in evaluating the response to NACT compared to histopathology. CAD analysis led to more false-negative findings (37.0%) compared to visual evaluation (11.1%), resulting in sensitivity of 52.4%, specificity of 100.0%, and diagnostic accuracy of 63.0%. The following dynamic MRI parameters showed significant associations to occurring metastases: Post-initial curve type before NACT (entire lesions, calculated by CAD) and post-initial curve type of the most enhancing tumor parts after NACT (calculated by CAD and manually). CONCLUSIONS In the accurate evaluation of response to neoadjuvant treatment, CAD systems can provide useful additional information due to the high specificity; however, they cannot replace visual imaging evaluation. Besides traditional prognostic factors, contrast medium-induced dynamic MRI parameters reveal significant associations to patient outcome, i.e. occurrence of distant metastases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. To evaluate the diagnostic benefit of real-time elastography (RTE) in clinical routine. Strain indices (SI) for benign and malignant tumors were assessed. Methods. 100 patients with 110 focal breast lesions were retrieved. Patients had mammography (MG), ultrasound (US), and, if necessary, MRI. RTE was conducted after ultrasound. Lesions were assessed with BI-RADS for mammography and ultrasound. Diagnosis was established with histology or follow-up. Results. SI for BI-RADS 2 was 1.71 ± 0.86. Higher SI (2.21 ± 1.96) was observed for BI-RADS 3 lesions. SI of BI-RADS 4 and 5 lesions were significantly higher (16.92 ± 20.89) and (19.54 ± 10.41). 31 malignant tumors exhibited an average SI of 16.13 ± 14.67; SI of benign lesions was 5.29 ± 11.87 (P value <0.0001). ROC analysis threshold was >3.8 for malignant disease. Sensitivity of sonography was 90.3% (specificity 78.5%). RTE showed a sensitivity of 87.1% (specificity 79.7%). Accuracy of all modalities combined was 96.8%. In BI-RADS 3 lesions RTE was able to detect all malignant lesions (sensitivity 100%, specificity 92.9%, and accuracy 93.9%). Conclusions. RTE increased sensitivity and specificity for breast cancer detection when used in combination with ultrasound.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Our commentary of the article “‘Screening’ for Breast Cancer: Misguided Research Misinforming Public Policies” has two main parts. First we address some of the methodological points raised by Professor Miettinen. Then we review more specific aspects of the Swiss Medical Board statement on mammography screening for early detection of breast cancer.