36 resultados para BIODEGRADABLE MICROPARTICLES

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Incomplete endothelialization has been found to be associated with late stent thrombosis, a rare but devastating phenomenon, more frequent after drug-eluting stent implantation. Optical coherence tomography (OCT) has 10 times greater resolution than intravascular ultrasound and thus appears to be a valuable modality for the assessment of stent strut coverage. The LEADERS trial was a multi-centre, randomized comparison of a biolimus-eluting stent (BES) with biodegradable polymer with a sirolimus-eluting stent (SES) using a durable polymer. This study sought to evaluate tissue coverage and apposition of stents using OCT in a group of patients from the randomized LEADERS trial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study reports the 12-month clinical outcomes of the LEADERS clinical trial which compared a biolimus eluting stent with a biodegradable polymer (BES) to a sirolimus eluting stent with a durable polymer (SES).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of endothelial cell (EC)-derived surface molecules in the circulation is among hallmarks of endothelial activation and damage in vivo. Previous investigations suggest that upregulation of T-cadherin (T-cad) on the surface of ECs may be a characteristic marker of EC activation and stress. We investigated whether T-cad might also be shed from ECs and in amounts reflecting the extent of activation or damage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The effectiveness of durable polymer drug-eluting stents comes at the expense of delayed arterial healing and subsequent late adverse events such as stent thrombosis (ST). We report the 4 year follow-up of an assessment of biodegradable polymer-based drug-eluting stents, which aim to improve safety by avoiding the persistent inflammatory stimulus of durable polymers. Methods We did a multicentre, assessor-masked, non-inferiority trial. Between Nov 27, 2006, and May 18, 2007, patients aged 18 years or older with coronary artery disease were randomly allocated with a computer-generated sequence to receive either biodegradable polymer biolimus-eluting stents (BES) or durable polymer sirolimus-eluting stents (SES; 1:1 ratio). The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation (TVR); patients were followed-up for 4 years. Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00389220. Findings 1707 patients with 2472 lesions were randomly allocated to receive either biodegradable polymer BES (857 patients, 1257 lesions) or durable polymer SES (850 patients, 1215 lesions). At 4 years, biodegradable polymer BES were non-inferior to durable polymer SES for the primary endpoint: 160 (18·7%) patients versus 192 (22·6%) patients (rate ratios [RR] 0·81, 95% CI 0·66–1·00, p for non-inferiority <0·0001, p for superiority=0·050). The RR of definite ST was 0·62 (0·35–1·08, p=0·09), which was largely attributable to a lower risk of very late definite ST between years 1 and 4 in the BES group than in the SES group (RR 0·20, 95% CI 0·06–0·67, p=0·004). Conversely, the RR of definite ST during the first year was 0·99 (0·51–1·95; p=0·98) and the test for interaction between RR of definite ST and time was positive (pinteraction=0·017). We recorded an interaction with time for events associated with ST but not for other events. For primary endpoint events associated with ST, the RR was 0·86 (0·41–1·80) during the first year and 0·17 (0·04–0·78) during subsequent years (pinteraction=0·049). Interpretation Biodegradable polymer BES are non-inferior to durable polymer SES and, by reducing the risk of cardiac events associated with very late ST, might improve long-term clinical outcomes for up to 4 years compared with durable polymer SES. Funding Biosensors Europe SA, Switzerland.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biolimus-eluting stents (BESs) with a biodegradable polymer in abluminal coating achieve more complete coverage at 9 months compared with sirolimus-eluting stents (SESs) with a durable polymer, as assessed by optical coherence tomography (OCT). Whether this advantage persists or augments after complete resorption of the polymer (>12 months) is unknown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: The current study reports clinical outcomes at three year follow-up of the LEADERS clinical trial which was the first all-comers trial comparing a new generation biodegradable polymer biolimus drug-eluting stent (BES) with the first generation permanent polymer sirolimus-eluting stent (SES). Methods and results: One thousand seven hundred and seven patients were randomised to unrestricted use of BES (n=857) or SES (n=850) in an all-comers population. Three year follow-up was available in 95% of the patients, 812 treated with BES and 809 treated with SES. At three years, BES remains non-inferior to SES for the primary endpoint of major adverse cardiac events (composite of cardiac death, myocardial infarction (MI), or clinically-indicated target vessel revascularisation (CI-TVR) (BES 15.7% versus SES 19%; HR 0.82 CI 0.65-1.03; p=0.09). The MACE Kaplan Meier event curves increasingly diverge with the difference in events increasing from 1.4% to 2.4% and 3.3% at 1, 2 and 3 years, respectively in favour of BES. The rate of cardiac death was non-significantly lower 4.2% versus 5.2% (HR=0.81 CI 0.52-1.26; p=0.34) and the rate of myocardial infarction was equivalent 7.2% versus 7.1% (HR 1.01 CI 0.70-1.44; p=0.97) for BES versus SES, respectively. Thus BES was non-inferior to SES in all the safety endpoints. Clinically-indicated TVR occurred in 9.4% of BES treated patients versus 11.1% of SES treated patients (HR 0.84 CI 0.62-1.13; p=0.25). Rates of definite stent thrombosis were 2.2% for BES and 2.9% for SES (HR 0.78 CI 0.43-1.43; p=0.43), with the event rate increase of 0.2% from one to three years for BES and 0.9% for SES. For patients presenting with ST-elevation myocardial infarction BES was superior to SES in reducing MACE. Conclusions: The findings of the three year follow-up support the claim that the biodegradable polymer biolimus-eluting stent has equivalent safety and efficacy to permanent polymer sirolimus-eluting stent in an all-comers patient population. Its performance is superior in some subpopulations such as in ST-elevation MI patients and event rates for BES are overall lower than for SES with a trend toward increasing divergence of outcomes over three years. - See more at: http://www.pcronline.com/eurointervention/42nd_issue/125/#sthash.E5HhMQ4a.dpuf

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The SYNTAX score (SXscore) has been shown to be an effective predictor of clinical outcomes in patients undergoing percutaneous coronary intervention (PCI). Methods and results: The SXscore was prospectively collected in 1,397 of the 1,707 patients enrolled in the “all-comers” LEADERS trial (patients post-surgical revascularisation were excluded). Post hoc analysis was performed by stratifying clinical outcomes at two-year follow-up, according to one of three SXscore tertiles: SXlow ≤8 (n=464), 816 (n=461). At two-year follow-up the rate of major adverse cardiovascular events was 18.4%, 12.0% and 9.4% in the SXhigh, SXmid, and SXlow tertile, respectively (HR 1.45; CI 1.21-1.74; p<0.01). There was a significantly higher rate of cardiac death in patients in the highest SXscore tertile (7% SXhigh versus 2.4% SXmid versus 1.8% SXlow; HR 2.22; CI 1.5-3.27; p<0.001). Within the SXhigh tertile the rate of cardiac death was significantly lower in patients treated with the biolimus-eluting stent compared with the sirolimus-eluting stent (4.7% versus 9.6%, HR 0.48; CI 0.23-0.99; p=0.046). Conclusions: The SXscore when applied to an “all-comers” patient population allows for prospective risk stratification of patients undergoing PCI up to two years follow-up. In addition, the SXscore appears to separate the performance of devices in high risk patient groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives This study sought to investigate safety and efficacy of biolimus-eluting stents (BES) with biodegradable polymer as compared with sirolimus-eluting stents (SES) with durable polymer through 2 years of follow-up. Background BES with a biodegradable polymer provide similar efficacy and safety as SES with a durable polymer at 9 months. Clinical outcomes beyond the period of biodegradation of the polymer used for drug release and after discontinuation of dual antiplatelet therapy are of particular interest. Methods A total of 1,707 patients were randomized to unrestricted use of BES (n = 857) or SES (n = 850) in an all-comers patient population. Results At 2 years, BES remained noninferior compared with SES for the primary endpoint, which was a composite of cardiac death, myocardial infarction, or clinically indicated target vessel revascularization (BES 12.8% vs. SES 15.2%, hazard ratio [HR]: 0.84, 95% confidence interval [CI]: 0.65 to 1.08, pnoninferiority < 0.0001, psuperiority = 0.18). Rates of cardiac death (3.2% vs. 3.9%, HR: 0.81, 95% CI: 0.49 to 1.35, p = 0.42), myocardial infarction (6.3% vs. 5.6%, HR: 1.12, 95% CI: 0.76 to 1.65, p = 0.56), and clinically indicated target vessel revascularization (7.5% vs. 8.6%, HR: 0.86, 95% CI: 0.62 to 1.20, p = 0.38) were similar for BES and SES. The rate of definite stent thrombosis through 2 years was 2.2% for BES and 2.5% for SES (p = 0.73). For the period between 1 and 2 years, event rates for definite stent thrombosis were 0.2% for BES and 0.5% for SES (p = 0.42). After discontinuation of dual antiplatelet therapy, no very late definite stent thrombosis occurred in the BES group. Conclusions At 2 years of follow-up, the unrestricted use of BES with a biodegradable polymer maintained a similar safety and efficacy profile as SES with a durable polymer. (Limus Eluted From a Durable Versus Erodable Stent Coating [LEADERS]; NCT00389220)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The efficacy of durable polymer drug-eluting stents (DES) is delivered at the expense of delayed healing of the stented vessel. Biodegradable polymer DES aim to avoid this shortcoming and may potentially improve long-term clinical outcomes, with benefit expected to accrue over time. We sought to compare long-term outcomes in patients treated with biodegradable polymer DES vs. durable polymer sirolimus-eluting stents (SES).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The efficacy and safety of drug-eluting stents compared with bare-metal stents remains controversial in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, a clinical study on patients with stable coronary artery disease (CAD) showed that external counterpulsation therapy (ECP) at high (300 mmHg) but not at low inflation pressure (80 mmHg) promoted coronary collateral growth, most likely due to shear stress-induced arteriogenesis. The exact molecular mechanisms behind shear stress-induced arteriogenesis are still obscure. We therefore characterized plasma levels of circulating microparticles (MPs) from these CAD patients because of their ambivalent nature as a known cardiovascular risk factor and as a promoter of neovascularization in the case of platelet-derived MPs. MPs positive for Annexin V and CD31CD41 were increased, albeit statistically significant (P<0.05, vs. baseline) only in patients receiving high inflation pressure ECP as determined by flow cytometry. MPs positive for CD62E, CD146, and CD14 were unaffected. In high, but not in low, inflation pressure treatment, change of CD31CD41 was inversely correlated to the change in collateral flow index (CFI), a measure for collateral growth. MPs from the high inflation pressure group had a more sustained pro-angiogenic effect than the ones from the low inflation pressure group, with the exception of one patient showing also an increased CFI after treatment. A total of 1005 proteins were identified by a label-free proteomics approach from MPs of three patients of each group applying stringent acceptance criteria. Based on semi-quantitative protein abundance measurements, MPs after ECP therapy contained more cellular proteins and increased CD31, corroborating the increase in MPs. Furthermore, we show that MP-associated factors of the innate immune system were decreased, many membrane-associated signaling proteins, and the known arteriogenesis stimulating protein transforming growth factor beta-1 were increased after ECP therapy. In conclusion, our data show that ECP therapy increases platelet-derived MPs in patients with CAD and that the change in protein cargo of MPs is likely in favor of a pro angiogenic/arteriogenic property.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE(S): Even though the mechanism is not clearly understood, direct intramyocardial cell transplantation has demonstrated potential to treat patients with severe heart failure. We previously reported on the bioengineering of myoblast-based constructs. We investigate here the functional outcome of infarcted hearts treated by implantation of myoblast-seeded scaffolds. METHODS: Adult Lewis rats with echocardiography-confirmed postinfarction reduced ejection fraction (48.3% +/- 1.1%) were randomized to (1) implantation of myoblast-seeded polyurethane patches at the site of infarction (PU-MyoB, n = 11), (2) implantation of nonseeded polyurethane patches (PU, n = 11), (3) sham operation (Sham, n = 12), and (4) direct intramyocardial myoblast injection (MyoB, n = 11). Four weeks later, the functional assessment by echocardiography was repeated, and we additionally performed left ventricular catheterization plus histologic studies. RESULTS: The ejection fraction significantly decreased in the PU (39.1% +/- 2.3%; P = .02) and Sham (39.9% +/- 3.5%; P = .04) groups, whereas it remained stable in the PU-MyoB (48.4% +/- 3.1%) and MyoB (47.9% +/- 3.0%) groups during the observation time. Similarly, left ventricular contractility was significantly higher in groups PU-MyoB (4960 +/- 266 mm Hg/s) and MyoB (4748 +/- 304 mm Hg/s) than in groups PU (3909 +/- 248 mm Hg/s, P = .01) and Sham (4028 +/- 199 mm Hg/s, P = .01). Immunohistology identified a high density of myoblasts within the seeded scaffolds without any migration toward the host cardiac tissue and no evidence of cardiac cell differentiation. CONCLUSIONS: Myoblast-seeded polyurethane scaffolds prevent post-myocardial infarction progression toward heart failure as efficiently as direct intramyocardial injection. The immunohistologic analysis suggests that an indirect mechanism, potentially a paracrine effect, may be assumed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: A novel stent platform eluting biolimus, a sirolimus analogue, from a biodegradable polymer showed promising results in preliminary studies. We compared the safety and efficacy of a biolimus-eluting stent (with biodegradable polymer) with a sirolimus-eluting stent (with durable polymer). METHODS: We undertook a multicentre, assessor-blind, non-inferiority study in ten European centres. 1707 patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes were centrally randomised by a computer-generated allocation sequence to treatment with either biolimus-eluting (n=857) or sirolimus-eluting (n=850) stents. The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation within 9 months. Analysis was by intention to treat. 427 patients were randomly allocated to angiographic follow-up, with in-stent percentage diameter stenosis as principal outcome measure at 9 months. The trial is registered with ClinicalTrials.gov, number NCT00389220. FINDINGS: We analysed all randomised patients. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents for the primary endpoint at 9 months (79 [9%] patients vs 89 [11%], rate ratio 0.88 [95% CI 0.64-1.19], p for non-inferiority=0.003, p for superiority=0.39). Frequency of cardiac death (14 [1.6%] vs 21 [2.5%], p for superiority=0.22), myocardial infarction (49 [5.7%] vs 39 [4.6%], p=0.30), and clinically-indicated target vessel revascularisation (38 [4.4%] vs 47 [5.5%], p=0.29) were similar for both stent types. 168 (79%) patients in the biolimus-eluting group and 167 (78%) in the sirolimus-eluting group had data for angiographic follow-up available. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents in in-stent percentage diameter stenosis (20.9%vs 23.3%, difference -2.2% [95% CI -6.0 to 1.6], p for non-inferiority=0.001, p for superiority=0.26). INTERPRETATION: Our results suggest that a stent eluting biolimus from a biodegradable polymer represents a safe and effective alternative to a stent eluting sirolimus from a durable polymer in patients with chronic stable coronary artery disease or acute coronary syndromes. FUNDING: Biosensors Europe SA, Switzerland.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plasma microparticles (MPs, <1.5 mum) originate from platelet and cell membrane lipid rafts and possibly regulate inflammatory responses and thrombogenesis. These actions are mediated through their phospholipid-rich surfaces and associated cell-derived surface molecules. The ectonucleotidase CD39/ecto-nucleoside triphosphate diphosphohydrolase1 (E-NTPDase1) modulates purinergic signalling through pericellular ATP and ADP phosphohydrolysis and is localized within lipid rafts in the membranes of endothelial- and immune cells. This study aimed to determine whether CD39 associates with circulating MPs and might further impact phenotype and function. Plasma MPs were found to express CD39 and exhibited classic E-NTPDase ecto-enzymatic activity. Entpd1 (Cd39) deletion in mice produced a pro-inflammatory phenotype associated with quantitative and qualitative differences in the MP populations, as determined by two dimensional-gel electrophoresis, western blot and flow cytometry. Entpd1-null MPs were also more abundant, had significantly higher proportions of platelet- and endothelial-derived elements and decreased levels of interleukin-10, tumour necrosis factor receptor 1 and matrix metalloproteinase 2. Consequently, Cd39-null MP augment endothelial activation, as determined by inflammatory cytokine release and upregulation of adhesion molecules in vitro. In conclusion, CD39 associates with circulating MP and may directly or indirectly confer functional properties. Our data also suggest a modulatory role for CD39 within MP in the exchange of regulatory signals between leucocytes and vascular cells.