131 resultados para Surgical instruments and apparatus


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Traumatic knee dislocation represents a rare but devastating injury. Several controversies persist regarding type of treatment, surgical timing, graft selection, repair versus reconstruction of the medial and lateral structures, surgical techniques and postoperative rehabilitation. A new technique for primary ACL stabilization, dynamic intaligamentary stabilization (DIS) was developed at the authors' institution. The purpose of this study was to analyze the clinical and radiological outcomes of surgically treated traumatic knee dislocations by means of the DIS technique for the ACL, primary suturing for PCL, MCL and LCL. METHODS Between 2009 and 2012, 35 patients treated surgically for traumatic knee dislocation with primary anterior cruciate ligament (ACL) reconstruction with DIS, suturing of the posterior cruciate ligament (PCL) and primary complete repair of collaterals, were evaluated clinically (IKDC score, SF12 health survey, Lysholm score, Tegner score) and radiologically with a mean follow up of 2.2 years (range 1.00-3.50 years) years. Instrumented anterior-posterior translation was measured (KT-2000). RESULTS Anterior/posterior translation (KT-2000) for the healthy and injured limb was 4.8mm (range 3-8mm) and 7.3mm (range 5-10) (89N) respectively. Valgus and varus stress testing in 30° flexion was normal in 26 (75%) and 29 (83%) patients, respectively. The IKDC score was B in 29 (83%) and C in 6 (17%) patients, while the mean Tegner score was 6 (range 4-8). The mean Lysholm score was 90.83 (range 81-95) and mean SF-12 physical and mental scores were 54.1 (range 45-60) and 51.0 (range 39-62) respectively. In 2 patients, a secondary operation was performed. CONCLUSIONS Early, one stage reconstruction with DIS can achieve good functional results and patient satisfaction with overall restoration of sports and working capacity without graft requirements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To investigate the prevalence of discontinuation and nonpublication of surgical versus medical randomized controlled trials (RCTs) and to explore risk factors for discontinuation and nonpublication of surgical RCTs. BACKGROUND: Trial discontinuation has significant scientific, ethical, and economic implications. To date, the prevalence of discontinuation of surgical RCTs is unknown. METHODS: All RCT protocols approved between 2000 and 2003 by 6 ethics committees in Canada, Germany, and Switzerland were screened. Baseline characteristics were collected and, if published, full reports retrieved. Risk factors for early discontinuation for slow recruitment and nonpublication were explored using multivariable logistic regression analyses. RESULTS: In total, 863 RCT protocols involving adult patients were identified, 127 in surgery (15%) and 736 in medicine (85%). Surgical trials were discontinued for any reason more often than medical trials [43% vs 27%, risk difference 16% (95% confidence interval [CI]: 5%-26%); P = 0.001] and more often discontinued for slow recruitment [18% vs 11%, risk difference 8% (95% CI: 0.1%-16%); P = 0.020]. The percentage of trials not published as full journal article was similar in surgical and medical trials (44% vs 40%, risk difference 4% (95% CI: -5% to 14%); P = 0.373). Discontinuation of surgical trials was a strong risk factor for nonpublication (odds ratio = 4.18, 95% CI: 1.45-12.06; P = 0.008). CONCLUSIONS: Discontinuation and nonpublication rates were substantial in surgical RCTs and trial discontinuation was strongly associated with nonpublication. These findings need to be taken into account when interpreting surgical literature. Surgical trialists should consider feasibility studies before embarking on full-scale trials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Both acetabular undercoverage (hip dysplasia) and overcoverage (pincer-type femoroacetabular impingement) can result in hip osteoarthritis. In contrast to undercoverage, there is a lack of information on radiographic reference values for excessive acetabular coverage. Questions/purposes (1) How do common radiographic hip parameters differ in hips with a deficient or an excessive acetabulum in relation to a control group; and (2) what are the reference values determined from these data for acetabular under- and overcoverage? Methods We retrospectively compared 11 radiographic parameters describing the radiographic acetabular anatomy among hip dysplasia (26 hips undergoing periacetabular osteotomy), control hips (21 hips, requiring no rim trimming during surgical hip dislocation), hips with overcoverage (14 hips, requiring rim trimming during surgical hip dislocation), and hips with severe overcoverage (25 hips, defined as having acetabular protrusio). The hips were selected from a patient cohort of a total of 593 hips. Radiographic parameters were assessed with computerized methods on anteroposterior pelvic radiographs and corrected for neutral pelvic orientation with the help of a true lateral radiograph. Results All parameters except the crossover sign differed among the four study groups. From dysplasia through control and overcoverage, the lateral center-edge angle, acetabular arc, and anteroposterior/craniocaudal coverage increased. In contrast, the medial center-edge angle, extrusion/acetabular index, Sharp angle, and prevalence of the posterior wall sign decreased. The following reference values were found: lateral center-edge angle 23° to 33°, medial center-edge angle 35° to 44°, acetabular arc 61° to 65°, extrusion index 17% to 27%, acetabular index 3° to 13°, Sharp angle 38° to 42°, negative crossover sign, positive posterior wall sign, anterior femoral head coverage 15% to 26%, posterior femoral head coverage 36% to 47%, and craniocaudal coverage 70% to 83%. Conclusions These acetabular reference values define excessive and deficient coverage. They may be used for radiographic evaluation of symptomatic hips, may offer possible predictors for surgical outcomes, and serve to guide clinical decision-making.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Complete-pelvis segmentation in antero-posterior pelvic radiographs is required to create a patient-specific three-dimensional pelvis model for surgical planning and postoperative assessment in image-free navigation of total hip arthroplasty. Methods A fast and robust framework for accurately segmenting the complete pelvis is presented, consisting of two consecutive modules. In the first module, a three-stage method was developed to delineate the left hemipelvis based on statistical appearance and shape models. To handle complex pelvic structures, anatomy-specific information processing techniques were employed. As the input to the second module, the delineated left hemi-pelvis was then reflected about an estimated symmetry line of the radiograph to initialize the right hemi-pelvis segmentation. The right hemi-pelvis was segmented by the same three-stage method, Results Two experiments conducted on respectively 143 and 40 AP radiographs demonstrated a mean segmentation accuracy of 1.61±0.68 mm. A clinical study to investigate the postoperative assessment of acetabular cup orientations based on the proposed framework revealed an average accuracy of 1.2°±0.9° and 1.6°±1.4° for anteversion and inclination, respectively. Delineation of each radiograph costs less than one minute. Conclusions Despite further validation needed, the preliminary results implied the underlying clinical applicability of the proposed framework for image-free THA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Zusammenfassung Hintergrund. Hämodialysepatienten, die operativ mit einem Gefäßzugang versorgt werden müssen, sind eine vulnerable Patientengruppe, die aufgrund von Multimorbidität, der intensiven und oft fragmentierten Behandlung und vieler Schnittstellen ein erhöhtes Risiko für vermeidbare unerwünschte Ereignisse tragen. Fragestellung. Aktuelle Entwicklungen und Maßnahmen zur Förderung der Patientensicherheit mit Fokus auf die Shuntchirurgie. Material und Methoden. Auswertung und Aufarbeitung aktueller Daten zur Patientensicherheit und Instrumenten zu ihrer Förderung. Ergebnisse. Fehler im nicht operativen Management verursachen einen wesentlichen Anteil der unerwünschten Ereignisse. Checklisten, präoperative Seitenmarkierung, Zählkontrollen und interprofessionelle Teamtrainings sind wichtige Instrumente der Patientensicherheit im OP. Standardisierungen von postoperativen Übergaben durch einfache Protokolle können erheblich zur Reduktion von Fehlern und Schädigungen beitragen. Die Sicherheitskultur einer Abteilung ist ein Umgebungsfaktor, der für die Effektivität dieser Sicherheitsbarrieren wesentlich ist. Schlussfolgerungen. Es existieren wirksame Instrumente, die die Patientensicherheit in der Shuntchirurgie fördern. Gerade an den Schnittstellen zur weiteren Versorgung können durch die konsequente Implementierung und Nutzung dieser Maßnahmen und ein aktives Sicherheitsmanagement unerwünschte Ereignisse vermieden werden. Die interprofessionelle und interdisziplinäre Zusammenarbeit und der Einbezug der Patienten sind wichtige Ressource für die Behandlungssicherheit, die stärker genutzt werden sollten.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To assess the current state of reporting of pain outcomes in Cochrane reviews on chronic musculoskeletal painful conditions and to elicit opinions of patients, healthcare practitioners, and methodologists on presenting pain outcomes to patients, clinicians, and policymakers. METHODS We identified all reviews in the Cochrane Library of chronic musculoskeletal pain conditions from Cochrane review groups (Back, Musculoskeletal, and Pain, Palliative, and Supportive Care) that contained a summary of findings (SoF) table. We extracted data on reported pain domains and instruments and conducted a survey and interviews on considerations for SoF tables (e.g., pain domains, presentation of results). RESULTS Fifty-seven SoF tables in 133 Cochrane reviews were eligible. SoF tables reported pain in 56/57, with all presenting results for pain intensity (20 different outcome instruments), pain interference in 8 SoF tables (5 different outcome instruments), and pain frequency in 1 multiple domain instrument. Other domains like pain quality or pain affect were not reported. From the survey and interviews [response rate 80% (36/45)], we derived 4 themes for a future research agenda: pain domains, considerations for assessing truth, discrimination, and feasibility; clinically important thresholds for responder analyses and presenting results; and establishing hierarchies of outcome instruments. CONCLUSION There is a lack of standardization in the domains of pain selected and the manner that pain outcomes are reported in SoF tables, hampering efforts to synthesize evidence. Future research should focus on the themes identified, building partnerships to achieve consensus and develop guidance on best practices for reporting pain outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A fast and automatic method for radiocarbon analysis of aerosol samples is presented. This type of analysis requires high number of sample measurements of low carbon masses, but accepts precisions lower than for carbon dating analysis. The method is based on online Trapping CO2 and coupling an elemental analyzer with a MICADAS AMS by means of a gas interface. It gives similar results to a previously validated reference method for the same set of samples. This method is fast and automatic and typically provides uncertainties of 1.5–5% for representative aerosol samples. It proves to be robust and reliable and allows for overnight and unattended measurements. A constant and cross contamination correction is included, which indicates a constant contamination of 1.4 ± 0.2 μg C with 70 ± 7 pMC and a cross contamination of (0.2 ± 0.1)% from the previous sample. A Real-time online coupling version of the method was also investigated. It shows promising results for standard materials with slightly higher uncertainties than the Trapping online approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work applies higher order auxiliary excitation techniques to two types of quadrupole mass spectrometers (QMSs): commercial systems and spaceborne instruments. The operational settings of a circular rod geometry commercial system and an engineering test-bed for a hyperbolic rod geometry spaceborne instrument were matched, with the relative performance of each sensor characterized with and without applied excitation using isotopic measurements of Kr+. Each instrument was operated at the limit of the test electronics to determine the effect of auxiliary excitation on extending instrument capabilities. For the circular rod sensor, with applied excitation, a doubling of the mass resolution at 1% of peak transmission resulted from the elimination of the low-mass side peak tail typical of such rod geometries. The mass peak stability and ion rejection efficiency were also increased by factors of 2 and 10, respectively, with voltage scan lines passing through the center of stability islands formed from auxiliary excitation. Auxiliary excitation also resulted in factors of 6 and 2 in peak stability and ion rejection efficiency, respectively, for the hyperbolic rod sensor. These results not only have significant implications for the use of circular rod quadrupoles with applied excitation as a suitable replacement for traditional hyperbolic rod sensors, but also for extending the capabilities of existing hyperbolic rod QMSs for the next generation of spaceborne instruments and low-mass commercial systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Unrepaired defects in the annulus fibrosus of intervertebral disks are associated with degeneration and persistent back pain. A clinical need exists for a disk repair strategy that can seal annular defects, be easily delivered during surgical procedures, and restore biomechanics with low risk of herniation. Multiple annulus repair strategies were developed using poly(trimethylene carbonate) scaffolds optimized for cell delivery, polyurethane membranes designed to prevent herniation, and fibrin-genipin adhesive tuned to annulus fibrosus shear properties. This three-part study evaluated repair strategies for biomechanical restoration, herniation risk and failure mode in torsion, bending and compression at physiological and hyper-physiological loads using a bovine injury model. Fibrin-genipin hydrogel restored some torsional stiffness, bending ROM and disk height loss, with negligible herniation risk and failure was observed histologically at the fibrin-genipin mid-substance following rigorous loading. Scaffold-based repairs partially restored biomechanics, but had high herniation risk even when stabilized with sutured membranes and failure was observed histologically at the interface between scaffold and fibrin-genipin adhesive. Fibrin-genipin was the simplest annulus fibrosus repair solution evaluated that involved an easily deliverable adhesive that filled irregularly-shaped annular defects and partially restored disk biomechanics with low herniation risk, suggesting further evaluation for disk repair may be warranted. Statement of significance Lower back pain is the leading cause of global disability and commonly caused by defects and failure of intervertebral disk tissues resulting in herniation and compression of adjacent nerves. Annulus fibrosus repair materials and techniques have not been successful due to the challenging mechanical and chemical microenvironment and the needs to restore biomechanical behaviors and promote healing with negligible herniation risk while being delivered during surgical procedures. This work addressed this challenging biomaterial and clinical problem using novel materials including an adhesive hydrogel, a scaffold capable of cell delivery, and a membrane to prevent herniation. Composite repair strategies were evaluated and optimized in quantitative three-part study that rigorously evaluated disk repair and provided a framework for evaluating alternate repair techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In spite of the environmental relevance of 129I, there is still a scarcity of data about its presence in the different natural compartments. In this work, results are presented on the concentration of 129I in rainwater samples taken in Sevilla (southwestern Spain) and in a sediment core taken near the Ringhals coast (Sweden). Typical concentrations of 108 and 109129I at/l are found in rainwater samples, similar to other values in literature. In the case of the sediment core, our results clearly show the impact of anthropogenic sources, with concentrations in the order of 1013129I at./kg and isotopic ratios 129I/127I in the order of 10−8 in the higher layers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sample preparation procedures for AMS measurements of 129I and 127I in environmental materials and some methodological aspects of quality assurance are discussed. Measurements from analyses of some pre-nuclear soil and thyroid gland samples and of a systematic investigation of natural waters in Lower Saxony, Germany, are described. Although the up-to-now lowest 129I/127I ratios in soils and thyroid glands were observed, they are still suspect to contamination since they are significantly higher than the pre-nuclear equilibrium ratio in the marine hydrosphere. A survey on all available 129I/127I isotopic ratios in precipitation shows a dramatic increase until the middle of the 1980s and a stabilization since 1987 at high isotopic ratios of about (3.6–8.3)×10−7. In surface waters, ratios of (57–380)×10−10 are measured while shallow ground waters show with ratios of (1.3–200)×10−10 significantly lower values with a much larger spread. The data for 129I in soils and in precipitation are used to estimate pre-nuclear and modern 129I deposition densities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Sutureless aortic valve replacement (SU-AVR) has emerged as an innovative alternative for treatment of aortic stenosis. By avoiding the placement of sutures, this approach aims to reduce cross-clamp and cardiopulmonary bypass (CPB) duration and thereby improve surgical outcomes and facilitate a minimally invasive approach suitable for higher risk patients. The present systematic review and meta-analysis aims to assess the safety and efficacy of SU-AVR approach in the current literature. METHODS Electronic searches were performed using six databases from their inception to January 2014. Relevant studies utilizing sutureless valves for aortic valve implantation were identified. Data were extracted and analyzed according to predefined clinical endpoints. RESULTS Twelve studies were identified for inclusion of qualitative and quantitative analyses, all of which were observational reports. The minimally invasive approach was used in 40.4% of included patients, while 22.8% underwent concomitant coronary bypass surgery. Pooled cross-clamp and CPB duration for isolated AVR was 56.7 and 46.5 minutes, respectively. Pooled 30-day and 1-year mortality rates were 2.1% and 4.9%, respectively, while the incidences of strokes (1.5%), valve degenerations (0.4%) and paravalvular leaks (PVL) (3.0%) were acceptable. CONCLUSIONS The evaluation of current observational evidence suggests that sutureless aortic valve implantation is a safe procedure associated with shorter cross-clamp and CPB duration, and comparable complication rates to the conventional approach in the short-term.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Alveolar echinococcosis (AE), a parasitic disease primarily of the liver caused by the larval stage of Echinococcus multilocularis, is highly endemic in Switzerland. In contrast to well-established management protocols in people, little is known with regard to optimal treatment strategies in dogs. The objective of this study was to describe the clinical signs and diagnostic procedures in dogs with AE and to evaluate outcome following medical treatment alone or surgery and medical treatment. Of 23 putative AE cases between 2004 and 2014, 20 were classified as confirmed (n=18) or probable (n=2) AE, based on abdominal ultrasound, serology, cytology, histology and/or PCR. Most dogs presented with abdominal distension in an advanced stage of disease. Dogs receiving specific treatment (radical or debulking surgery together with medical treatment, or medical treatment alone) survived longer than dogs left untreated, but no difference was found between treatment types. Survival at one year was associated with absence of free abdominal fluid, absence of abdominal distension and treatment of any type. However, dogs treated with debulking surgery all faced relapse. Findings of this study suggest that in AE-affected dogs for which a therapeutic approach is regarded appropriate by owners and veterinarians, radical surgical resection and medical treatment or, if total resection is not possible, medical treatment alone should be considered. However, studies on larger numbers of dogs are necessary before definitive treatment recommendations can be made.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Intravenous anaesthetic drugs are the primary means for producing general anaesthesia in equine practice. The ideal drug for intravenous anaesthesia has high reliability and pharmacokinetic properties indicating short elimination and lack of accumulation when administered for prolonged periods. Induction of general anaesthesia with racemic ketamine preceded by profound sedation has already an established place in the equine field anaesthesia. Due to potential advantages over racemic ketamine, S-ketamine has been employed in horses to induce general anaesthesia, but its optimal dose remains under investigation. The objective of this study was to evaluate whether 2.5 mg/kg S-ketamine could be used as a single intravenous bolus to provide short-term surgical anaesthesia in colts undergoing surgical castration, and to report its pharmacokinetic profile. RESULTS After premedication with romifidine and L-methadone, the combination of S-ketamine and diazepam allowed reaching surgical anaesthesia in the 28 colts. Induction of anaesthesia as well as recovery were good to excellent in the majority (n = 22 and 24, respectively) of the colts. Seven horses required additional administration of S-ketamine to prolong the duration of surgical anaesthesia. Redosing did not compromise recovery quality. Plasma concentration of S-ketamine decreased rapidly after administration, following a two-compartmental model, leading to the hypothesis of a consistent unchanged elimination of the parent compound into the urine beside its conversion to S-norketamine. The observed plasma concentrations of S-ketamine at the time of first movement were various and did not support the definition of a clear cut-off value to predict the termination of the drug effect. CONCLUSIONS The administration of 2.5 mg/kg IV S-ketamine after adequate premedication provided good quality of induction and recovery and a duration of action similar to what has been reported for racemic ketamine at the dose of 2.2 mg/kg. Until further investigations will be provided, close monitoring to adapt drug delivery is mandatory, particularly once the first 10 minutes after injection are elapsed. Taking into account rapid elimination of S-ketamine, significant inter-individual variability and rapid loss of effect over a narrow range of concentrations a sudden return of consciousness has to be foreseen.