Comparing the performance of hyperbolic and circular rod quadrupole mass spectrometers with applied higher order auxiliary excitation


Autoria(s): Gershman, D.J.; Block, B.P.; Rubin, Martin; Benna, M.; Mahaffy, P.R.; Zurbuchen, T.H.
Data(s)

2012

Resumo

This work applies higher order auxiliary excitation techniques to two types of quadrupole mass spectrometers (QMSs): commercial systems and spaceborne instruments. The operational settings of a circular rod geometry commercial system and an engineering test-bed for a hyperbolic rod geometry spaceborne instrument were matched, with the relative performance of each sensor characterized with and without applied excitation using isotopic measurements of Kr+. Each instrument was operated at the limit of the test electronics to determine the effect of auxiliary excitation on extending instrument capabilities. For the circular rod sensor, with applied excitation, a doubling of the mass resolution at 1% of peak transmission resulted from the elimination of the low-mass side peak tail typical of such rod geometries. The mass peak stability and ion rejection efficiency were also increased by factors of 2 and 10, respectively, with voltage scan lines passing through the center of stability islands formed from auxiliary excitation. Auxiliary excitation also resulted in factors of 6 and 2 in peak stability and ion rejection efficiency, respectively, for the hyperbolic rod sensor. These results not only have significant implications for the use of circular rod quadrupoles with applied excitation as a suitable replacement for traditional hyperbolic rod sensors, but also for extending the capabilities of existing hyperbolic rod QMSs for the next generation of spaceborne instruments and low-mass commercial systems.

Formato

application/pdf

Identificador

http://boris.unibe.ch/74097/1/1-s2.0-S1387380612001303-main.pdf

Gershman, D.J.; Block, B.P.; Rubin, Martin; Benna, M.; Mahaffy, P.R.; Zurbuchen, T.H. (2012). Comparing the performance of hyperbolic and circular rod quadrupole mass spectrometers with applied higher order auxiliary excitation. International journal of mass spectrometry, 319-320, pp. 17-24. Elsevier 10.1016/j.ijms.2012.03.008 <http://dx.doi.org/10.1016/j.ijms.2012.03.008>

doi:10.7892/boris.74097

info:doi:10.1016/j.ijms.2012.03.008

urn:issn:1387-3806

Idioma(s)

eng

Publicador

Elsevier

Relação

http://boris.unibe.ch/74097/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Gershman, D.J.; Block, B.P.; Rubin, Martin; Benna, M.; Mahaffy, P.R.; Zurbuchen, T.H. (2012). Comparing the performance of hyperbolic and circular rod quadrupole mass spectrometers with applied higher order auxiliary excitation. International journal of mass spectrometry, 319-320, pp. 17-24. Elsevier 10.1016/j.ijms.2012.03.008 <http://dx.doi.org/10.1016/j.ijms.2012.03.008>

Palavras-Chave #520 Astronomy #620 Engineering
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed