113 resultados para Medical instruments and apparatus
Resumo:
BACKGROUND: Effective lectures often incorporate activities that encourage learner participation. A challenge for educators is how to facilitate this in the large group lecture setting. This study investigates the individual student characteristics involved in encouraging (or dissuading) learners to interact, ask questions, and make comments in class. METHODS: Students enrolled in a Doctor of Veterinary Medicine program at Ross University School of Veterinary Medicine, St Kitts, were invited to complete a questionnaire canvassing their participation in the large group classroom. Data from the questionnaire were analyzed using Excel (Microsoft, Redmond, WA, USA) and the R software environment (http://www.r-project.org/). RESULTS: One hundred and ninety-two students completed the questionnaire (response rate, 85.7%). The results showed statistically significant differences between male and female students when asked to self-report their level of participation (P=0.011) and their confidence to participate (P<0.001) in class. No statistically significant difference was identified between different age groups of students (P=0.594). Student responses reflected that an "aversion to public speaking" acted as the main deterrent to participating during a lecture. Female participants were 3.56 times more likely to report a fear of public speaking than male participants (odds ratio 3.56, 95% confidence interval 1.28-12.33, P=0.01). Students also reported "smaller sizes of class and small group activities" and "other students participating" as factors that made it easier for them to participate during a lecture. CONCLUSION: In this study, sex likely played a role in learner participation in the large group veterinary classroom. Male students were more likely to participate in class and reported feeling more confident to participate than female students. Female students in this study commonly identified aversion to public speaking as a factor which held them back from participating in the large group lecture setting. These are important findings for veterinary and medical educators aiming to improve learner participation in the classroom. Potential ways of addressing this challenge include addition of small group activities and audience response systems during lectures, and inclusion of training interventions in public speaking at an early stage of veterinary and medical curricula.
Resumo:
OBJECTIVES The aim of this study was to identify common risk factors for patient-reported medical errors across countries. In country-level analyses, differences in risks associated with error between health care systems were investigated. The joint effects of risks on error-reporting probability were modelled for hypothetical patients with different health care utilization patterns. DESIGN Data from the Commonwealth Fund's 2010 lnternational Survey of the General Public's Views of their Health Care System's Performance in 11 Countries. SETTING Representative population samples of 11 countries were surveyed (total sample = 19,738 adults). Utilization of health care, coordination of care problems and reported errors were assessed. Regression analyses were conducted to identify risk factors for patients' reports of medical, medication and laboratory errors across countries and in country-specific models. RESULTS Error was reported by 11.2% of patients but with marked differences between countries (range: 5.4-17.0%). Poor coordination of care was reported by 27.3%. The risk of patient-reported error was determined mainly by health care utilization: Emergency care (OR = 1.7, P < 0.001), hospitalization (OR = 1.6, P < 0.001) and the number of providers involved (OR three doctors = 2.0, P < 0.001) are important predictors. Poor care coordination is the single most important risk factor for reporting error (OR = 3.9, P < 0.001). Country-specific models yielded common and country-specific predictors for self-reported error. For high utilizers of care, the probability that errors are reported rises up to P = 0.68. CONCLUSIONS Safety remains a global challenge affecting many patients throughout the world. Large variability exists in the frequency of patient-reported error across countries. To learn from others' errors is not only essential within countries but may also prove a promising strategy internationally.
Resumo:
PRINCIPALS Over a million people worldwide die each year from road traffic injuries and more than 10 million sustain permanent disabilities. Many of these victims are pedestrians. The present retrospective study analyzes the severity and mortality of injuries suffered by adult pedestrians, depending on whether they used a zebra crosswalk. METHODS Our retrospective data analysis covered adult patients admitted to our emergency department (ED) between 1 January 2000 and 31 December 2012 after being hit by a vehicle while crossing the road as a pedestrian. Patients were identified by using a string term. Medical, police and ambulance records were reviewed for data extraction. RESULTS A total of 347 patients were eligible for study inclusion. Two hundred and three (203; 58.5%) patients were on a zebra crosswalk and 144 (41.5%) were not. The mean ISS (injury Severity Score) was 12.1 (SD 14.7, range 1-75). The vehicles were faster in non-zebra crosswalk accidents (47.7 km/n, versus 41.4 km/h, p<0.027). The mean ISS score was higher in patients with non-zebra crosswalk accidents; 14.4 (SD 16.5, range 1-75) versus 10.5 (SD13.14, range 1-75) (p<0.019). Zebra crosswalk accidents were associated with less risk of severe injury (OR 0.61, 95% CI 0.38-0.98, p<0.042). Accidents involving a truck were associated with increased risk of severe injury (OR 3.53, 95%CI 1.21-10.26, p<0.02). CONCLUSION Accidents on zebra crosswalks are more common than those not on zebra crosswalks. The injury severity of non-zebra crosswalk accidents is significantly higher than in patients with zebra crosswalk accidents. Accidents involving large vehicles are associated with increased risk of severe injury. Further prospective studies are needed, with detailed assessment of motor vehicle types and speed.
Resumo:
Since 1987, Switzerland’s Federal Inventory of Mire Landscapes of Particular Beauty and National Importance has provided an instrument for the integration of nature conservation and landscape protection. Mires and mire landscape protection are strictly regulated. However, research results show that neither the goals of mire protection nor those of mire landscape protection are being achieved. The reasons for this are manifold and, in particular, have to do with a lack of coordination between the various policy areas that shape mire environments and mire landscapes. There are several key challenges involving different political and administrative levels. At the national level, mechanisms must be devised that enable differentiated regional implementation of national sectoral policies. In the context of cantonal structure planning, regional nature conservation and landscape protection priorities should be established based on existing regional potentials vis-à-vis the natural environment and landscapes (including protected biotopes and landscapes). At the regional level (spanning multiple communes), integrated planning instruments and governance structures should be developed so that implementation of national and cantonal sectoral policies may be harmonized under the umbrella of regional and integrated development plans. These adjustments to Switzerland’s institutional system are necessary to enable far-reaching integration of nature conservation and landscape protection when setting regional policy priorities. This would strengthen the protection of mire landscapes and other integrative instruments such as regional nature parks of national importance.
Resumo:
Background Complete-pelvis segmentation in antero-posterior pelvic radiographs is required to create a patient-specific three-dimensional pelvis model for surgical planning and postoperative assessment in image-free navigation of total hip arthroplasty. Methods A fast and robust framework for accurately segmenting the complete pelvis is presented, consisting of two consecutive modules. In the first module, a three-stage method was developed to delineate the left hemipelvis based on statistical appearance and shape models. To handle complex pelvic structures, anatomy-specific information processing techniques were employed. As the input to the second module, the delineated left hemi-pelvis was then reflected about an estimated symmetry line of the radiograph to initialize the right hemi-pelvis segmentation. The right hemi-pelvis was segmented by the same three-stage method, Results Two experiments conducted on respectively 143 and 40 AP radiographs demonstrated a mean segmentation accuracy of 1.61±0.68 mm. A clinical study to investigate the postoperative assessment of acetabular cup orientations based on the proposed framework revealed an average accuracy of 1.2°±0.9° and 1.6°±1.4° for anteversion and inclination, respectively. Delineation of each radiograph costs less than one minute. Conclusions Despite further validation needed, the preliminary results implied the underlying clinical applicability of the proposed framework for image-free THA.
Resumo:
QUESTION UNDER STUDY What are the trends in avoidable cancer mortality in Switzerland and neighbouring countries? METHODS Mortality data and population estimates 1996-2010 were obtained from the Swiss Federal Statistical Office for Switzerland and the World Health Organization Mortality Database (http://www.who.int/healthinfo/mortality_data/en/) for Austria, Germany, France and Italy. Age standardised mortality rates (ASMRs, European standard) per 100 000 person-years were calculated for the population <75 years old by sex for the following groups of cancer deaths: (1) avoidable through primary prevention; (2) avoidable through early detection and treatment; (3) avoidable through improved treatment and medical care; and (4) remaining cancer deaths. To assess time trends in ASMRs, estimated annual percentage changes (EAPCs) with 95% confidence intervals (95% CIs) were calculated. RESULTS In Switzerland and neighbouring countries cancer mortality in persons <75 years old continuously decreased 1996-2010. Avoidable cancer mortality decreased in all groups of avoidable cancer deaths in both sexes, with one exception. ASMRs for causes avoidable through primary prevention increased in females in all countries (in Switzerland from 16.2 to 20.3 per 100 000 person years, EAPC 2.0 [95% CI 1.4 to 2.6]). Compared with its neighbouring countries, Switzerland showed the lowest rates for all groups of avoidable cancer mortality in males 2008-2010. CONCLUSION Overall avoidable cancer mortality decreased, indicating achievements in cancer care and related health policies. However, increasing trends in avoidable cancer mortality through primary prevention for females suggest there is a need in Switzerland and its European neighbouring countries to improve primary prevention.
Resumo:
OBJECTIVE To assess the current state of reporting of pain outcomes in Cochrane reviews on chronic musculoskeletal painful conditions and to elicit opinions of patients, healthcare practitioners, and methodologists on presenting pain outcomes to patients, clinicians, and policymakers. METHODS We identified all reviews in the Cochrane Library of chronic musculoskeletal pain conditions from Cochrane review groups (Back, Musculoskeletal, and Pain, Palliative, and Supportive Care) that contained a summary of findings (SoF) table. We extracted data on reported pain domains and instruments and conducted a survey and interviews on considerations for SoF tables (e.g., pain domains, presentation of results). RESULTS Fifty-seven SoF tables in 133 Cochrane reviews were eligible. SoF tables reported pain in 56/57, with all presenting results for pain intensity (20 different outcome instruments), pain interference in 8 SoF tables (5 different outcome instruments), and pain frequency in 1 multiple domain instrument. Other domains like pain quality or pain affect were not reported. From the survey and interviews [response rate 80% (36/45)], we derived 4 themes for a future research agenda: pain domains, considerations for assessing truth, discrimination, and feasibility; clinically important thresholds for responder analyses and presenting results; and establishing hierarchies of outcome instruments. CONCLUSION There is a lack of standardization in the domains of pain selected and the manner that pain outcomes are reported in SoF tables, hampering efforts to synthesize evidence. Future research should focus on the themes identified, building partnerships to achieve consensus and develop guidance on best practices for reporting pain outcomes.
Resumo:
A fast and automatic method for radiocarbon analysis of aerosol samples is presented. This type of analysis requires high number of sample measurements of low carbon masses, but accepts precisions lower than for carbon dating analysis. The method is based on online Trapping CO2 and coupling an elemental analyzer with a MICADAS AMS by means of a gas interface. It gives similar results to a previously validated reference method for the same set of samples. This method is fast and automatic and typically provides uncertainties of 1.5–5% for representative aerosol samples. It proves to be robust and reliable and allows for overnight and unattended measurements. A constant and cross contamination correction is included, which indicates a constant contamination of 1.4 ± 0.2 μg C with 70 ± 7 pMC and a cross contamination of (0.2 ± 0.1)% from the previous sample. A Real-time online coupling version of the method was also investigated. It shows promising results for standard materials with slightly higher uncertainties than the Trapping online approach.
Resumo:
This work applies higher order auxiliary excitation techniques to two types of quadrupole mass spectrometers (QMSs): commercial systems and spaceborne instruments. The operational settings of a circular rod geometry commercial system and an engineering test-bed for a hyperbolic rod geometry spaceborne instrument were matched, with the relative performance of each sensor characterized with and without applied excitation using isotopic measurements of Kr+. Each instrument was operated at the limit of the test electronics to determine the effect of auxiliary excitation on extending instrument capabilities. For the circular rod sensor, with applied excitation, a doubling of the mass resolution at 1% of peak transmission resulted from the elimination of the low-mass side peak tail typical of such rod geometries. The mass peak stability and ion rejection efficiency were also increased by factors of 2 and 10, respectively, with voltage scan lines passing through the center of stability islands formed from auxiliary excitation. Auxiliary excitation also resulted in factors of 6 and 2 in peak stability and ion rejection efficiency, respectively, for the hyperbolic rod sensor. These results not only have significant implications for the use of circular rod quadrupoles with applied excitation as a suitable replacement for traditional hyperbolic rod sensors, but also for extending the capabilities of existing hyperbolic rod QMSs for the next generation of spaceborne instruments and low-mass commercial systems.
Resumo:
In spite of the environmental relevance of 129I, there is still a scarcity of data about its presence in the different natural compartments. In this work, results are presented on the concentration of 129I in rainwater samples taken in Sevilla (southwestern Spain) and in a sediment core taken near the Ringhals coast (Sweden). Typical concentrations of 108 and 109129I at/l are found in rainwater samples, similar to other values in literature. In the case of the sediment core, our results clearly show the impact of anthropogenic sources, with concentrations in the order of 1013129I at./kg and isotopic ratios 129I/127I in the order of 10−8 in the higher layers.
Resumo:
Sample preparation procedures for AMS measurements of 129I and 127I in environmental materials and some methodological aspects of quality assurance are discussed. Measurements from analyses of some pre-nuclear soil and thyroid gland samples and of a systematic investigation of natural waters in Lower Saxony, Germany, are described. Although the up-to-now lowest 129I/127I ratios in soils and thyroid glands were observed, they are still suspect to contamination since they are significantly higher than the pre-nuclear equilibrium ratio in the marine hydrosphere. A survey on all available 129I/127I isotopic ratios in precipitation shows a dramatic increase until the middle of the 1980s and a stabilization since 1987 at high isotopic ratios of about (3.6–8.3)×10−7. In surface waters, ratios of (57–380)×10−10 are measured while shallow ground waters show with ratios of (1.3–200)×10−10 significantly lower values with a much larger spread. The data for 129I in soils and in precipitation are used to estimate pre-nuclear and modern 129I deposition densities.
Resumo:
Künstliches Vitamin C ist heute ein Massenprodukt. Dass sich Ascorbinsäure seit ihrer Erfindung 1933 zu einem alltäglichen Konsumgut mausern konnte, ist weniger durch ihr medizinisches Potential zu erklären, sondern verdankt sich vielmehr einem dynamischen Zusammenspiel von Produktion, Vermarktung und Gesundheitspolitik. Der Beitrag fokussiert insbesondere auf die komplexen Interaktionen zwischen Gesundheitskonzepten, diagnostischen Instrumenten und ärztlichem Blick. Dabei scheinen nicht nur die Differenzen zwischen „rein naturwissenschaftlichen“ und „ärztlich-biologischen“ Standpunkten auf, sondern es zeigt sich auch, dass Nahrungsbestandteile immer auch gesundheitspolitisch und ethisch aufgeladen sind.
Resumo:
Carotid atherosclerotic disease is highly related to cerebrovascular events. Carotid endarterectomy is the common operation method to treat this disease. In this study, hemodynamics analyses are performed on the carotid arteries in three patients, whose right carotid artery had been treated by carotid endarterectomy and the left carotid artery remained untreated. Flow and loading conditions are compared between these treated and untreated carotid arteries and evaluation of the operative results is discussed. Patient-specific models are reconstructed from MDCT data. Intraoperative ultrasound flow measurements are performed on the treated carotid arteries and the obtained data are used as the boundary conditions of the models and the validations of the computational results. Finite volume method is employed to solve the transport equations and the flow and loading conditions of the models are reported. The results indicate that: (i) in two of the three patients, the internal-to-external flow rate ratio in the untreated carotid artery is larger than that in the treated one, and the average overall flow split ratio by summing up the data of both the left and right carotid arteries is about 2.15; (ii) in the carotid bulb, high wall shear stress occurs at the bifurcation near the external carotid artery in all of the cases without hard plaques; (iii) the operated arteries present low time-averaged wall shear stress at the carotid bulb, especially for the treated arteries with patch technique, indicating the possibility of the recurrence of stenosis; (iv) high temporal gradient of wall shear stress (>35 Pa/s) is shown in the narrowing regions along the vessels; and (v) in the carotid arteries without serious stenosis, the maximum velocity magnitude during mid-diastole is 32~37% of that at systolic peak, however, in the carotid artery with 50% stenosis by hard plaques, this value is nearly doubled (64%). The computational work quantifies flow and loading distributions in the treated and untreated carotid arteries of the same patient, contributing to evaluation of the operative results and indicating the recurrent sites of potential atheromatous plaques.