42 resultados para New left


Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS In 1999 the consensus statement "living anatomy of the atrioventricular junctions" was published. With that new nomenclature the former posteroseptal accessory pathway (APs) are termed paraseptal APs. The aim of this study was to identify ECG features of manifest APs located in this complex paraseptal space. METHODS AND RESULTS ECG characteristics of all patients who underwent radiofrequency ablation of an AP during a 3 year period were analyzed. Of the 239 patients with one or more APs, 30 patients had a paraseptal AP with preexcitation. Compared to APs within the coronary sinus (CS) or the middle cardiac vein (MCV) the right sided paraseptal APs significantly more often showed an isoelectric delta wave in lead II and/or a negative delta wave in aVR. The left sided paraseptal APs presented a negative delta wave in II significantly more often compared to the right sided APs. CONCLUSIONS According to the site of radiofrequency ablation, paraseptal APs are classified into 4 subgroups: paraseptal right, paraseptal left, inside the CS or inside the MCV. Subtle differences in preexcitation patterns of the delta wave as well as of the QRS complex exist. However, the definitive localization of APs remains reserved to the periinterventional intracardiac electrogram analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper will discuss how the gender perspective can be applied to the study of the Early Modern Jesuit China mission. I will show that the category of gender provides a promising research perspective on Sino-Western cultural exchange, for it brings to the forefront important aspects of social life in the “contact zone” of Chinese Christian communities. I will argue that through the intercultural contact initiated by the Jesuit China mission, gender roles started to shift slightly on both sides. On the one hand, the Jesuits adopted the Confucian ideal of the separation of the sexes (nannü zhi bie), building for example separate Churches for women, something unknown in Europe. On the other hand, Chinese Christians were urged to reconsider aspects of their traditional gender norms, when for instance some men left their concubines in order to become Christian. The paper will be divided in three parts. First, it will focus on the history of concepts and discuss what gender relations meant in the context of the Early Modern China mission. Then it will turn to the representation of female religiosity in Jesuit Annual Letters and show how the gender perspective can lead to a re-evaluation this source genre. Finally, it will reflect on how the gender perspective can give us fresh insights into well-known paradigms on Sino-Western relations, taking the accommodation paradigm as an example.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Higher visual functions can be defined as cognitive processes responsible for object recognition, color and shape perception, and motion detection. People with impaired higher visual functions after unilateral brain lesion are often tested with paper pencil tests, but such tests do not assess the degree of interaction between the healthy brain hemisphere and the impaired one. Hence, visual functions are not tested separately in the contralesional and ipsilesional visual hemifields. METHODS: A new measurement setup, that involves real-time comparisons of shape and size of objects, orientation of lines, speed and direction of moving patterns, in the right or left visual hemifield, has been developed. The setup was implemented in an immersive environment like a hemisphere to take into account the effects of peripheral and central vision, and eventual visual field losses. Due to the non-flat screen of the hemisphere, a distortion algorithm was needed to adapt the projected images to the surface. Several approaches were studied and, based on a comparison between projected images and original ones, the best one was used for the implementation of the test. Fifty-seven healthy volunteers were then tested in a pilot study. A Satisfaction Questionnaire was used to assess the usability of the new measurement setup. RESULTS: The results of the distortion algorithm showed a structural similarity between the warped images and the original ones higher than 97%. The results of the pilot study showed an accuracy in comparing images in the two visual hemifields of 0.18 visual degrees and 0.19 visual degrees for size and shape discrimination, respectively, 2.56° for line orientation, 0.33 visual degrees/s for speed perception and 7.41° for recognition of motion direction. The outcome of the Satisfaction Questionnaire showed a high acceptance of the battery by the participants. CONCLUSIONS: A new method to measure higher visual functions in an immersive environment was presented. The study focused on the usability of the developed battery rather than the performance at the visual tasks. A battery of five subtasks to study the perception of size, shape, orientation, speed and motion direction was developed. The test setup is now ready to be tested in neurological patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

During the winter of 1936-1937, British archaeologist John Garstang (1876-1956) excavated several trenches at the site of Sirkeli Höyük, located in the Plain of Cilicia (18 km west of modern-day Ceyhan). After a single campaign, however, he left the site and his interest shifted to site of Yumuktepe/Mersin, where he then excavated for a number of years. Apart from two very brief preliminary reports of his excavations at Sirkeli Höyük, which were published in the journal 'Annals of Archaeology and Anthropology of the University of Liverpool', not much is known about the trenches and their associated finds. Unpublished photographs kept in the Special Archives of University College London shed new light on the location and orientation of some of Garstang’s trenches at the site. Furthermore, in the 2012 campaign of the renewed Turkish-Swiss excavations at the site, a trench was found in the western part of the northern terrace that most probably was excavated by Garstang, but was not mentioned by him in his reports. This hitherto unknown trench may be related to his discovery of a lion-shaped column base made of basalt that is now kept in the collections of the Archaeological Museum of Adana.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Histomorphometric evaluation of the buccal aspects of periodontal tissues in rodents requires reproducible alignment of maxillae and highly precise sections containing central sections of buccal roots; this is a cumbersome and technically sensitive process due to the small specimen size. The aim of the present report is to describe and analyze a method to transfer virtual sections of micro-computer tomographic (CT)-generated image stacks to the microtome for undecalcified histological processing and to describe the anatomy of the periodontium in rat molars. A total of 84 undecalcified sections of all buccal roots of seven untreated rats was analyzed. The accuracy of section coordinate transfer from virtual micro-CT slice to the histological slice, right-left side differences and the measurement error for linear and angular measurements on micro-CT and on histological micrographs were calculated using the Bland-Altman method, interclass correlation coefficient and the method of moments estimator. Also, manual alignment of the micro-CT-scanned rat maxilla was compared with multiplanar computer-reconstructed alignment. The supra alveolar rat anatomy is rather similar to human anatomy, whereas the alveolar bone is of compact type and the keratinized gingival epithelium bends apical to join the junctional epithelium. The high methodological standardization presented herein ensures retrieval of histological slices with excellent display of anatomical microstructures, in a reproducible manner, minimizes random errors, and thereby may contribute to the reduction of number of animals needed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the suitability of a minipig model for the study of bone healing and osseointegration of dental implants following bone splitting and expansion of narrow ridges. MATERIAL AND METHODS In four minipigs, the mandibular premolars and first molars were extracted together with removal of the buccal bone plate. Three months later, ridge splitting and expansion was performed with simultaneous placement of three titanium implants per quadrant. On one side of the mandible, the expanded bone gap between the implants was filled with an alloplastic biphasic calcium phosphate (BCP) material, while the gap on the other side was left unfilled. A barrier membrane was placed in half of the quadrants. After a healing period of 6 weeks, the animals were sacrificed for histological evaluation. RESULTS In all groups, no bone fractures occurred, no implants were lost, all 24 implants were osseointegrated, and the gap created by bone splitting was filled with new bone, irrespective of whether BCP or a barrier membrane was used. Slight exposure of five implants was observed, but did not lead to implant loss. The level of the most coronal bone-to-implant contact varied without being dependent on the use of BCP or a barrier membrane. In all groups, the BCP particles were not present deep in the bone-filled gap. However, BCP particles were seen at the crestal bone margin, where they were partly integrated in the new bone. CONCLUSIONS This new minipig model holds great promise for studying experimental ridge splitting/expansion. However, efforts must be undertaken to reduce implant exposure and buccal bone resorption.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES The aim of the study was to investigate 4-year outcomes and predictors of repeat revascularization in patients treated with the Resolute zotarolimus-eluting stent (R-ZES) (Medtronic, Minneapolis, Minnesota) and XIENCE V everolimus-eluting stent (EES) (Abbott Vascular, Abbott Park, Illinois) in the RESOLUTE (A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention) All-Comers trial. BACKGROUND Data on long-term outcomes of new-generation drug-eluting stents are limited, and predictors of repeat revascularization due to restenosis and/or progression of disease are largely unknown. METHODS Patients were randomly assigned to treatment with the R-ZES (n = 1,140) or the EES (n = 1,152). We assessed pre-specified safety and efficacy outcomes at 4 years including target lesion failure and stent thrombosis. Predictors of revascularization at 4 years were identified by Cox regression analysis. RESULTS At 4 years, the rates of target lesion failure (15.2% vs. 14.6%, p = 0.68), cardiac death (5.4% vs. 4.7%, p = 0.44), and target vessel myocardial infarction (5.3% vs. 5.4%, p = 1.00), clinically-indicated target lesion revascularization (TLR) (7.0% vs. 6.5%, p = 0.62), and definite/probable stent thrombosis (2.3% vs. 1.6%, p = 0.23) were similar with the R-ZES and EES. Independent predictors of TLR were age, insulin-treated diabetes, SYNTAX (Synergy between PCI with Taxus and Cardiac Surgery) score, treatment of saphenous vein grafts, ostial lesions, and in-stent restenosis. Independent predictors of any revascularization were age, diabetes, previous percutaneous coronary intervention, absence of ST-segment elevation myocardial infarction, smaller reference vessel diameter, SYNTAX score, and treatment of left anterior descending, right coronary artery, saphenous vein grafts, ostial lesions, or in-stent restenosis. CONCLUSIONS R-ZES and EES demonstrated similar safety and efficacy throughout 4 years. TLR represented less than one-half of all repeat revascularization procedures. Patient- and lesion-related factors predicting the risk of TLR and any revascularization showed considerable overlap. (A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention [RESOLUTE-AC]; NCT00617084).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE Obtaining new details of radial motion of left ventricular (LV) segments using velocity-encoding cardiac MRI. METHODS Cardiac MR examinations were performed on 14 healthy volunteers aged between 19 and 26 years. Cine images for navigator-gated phase contrast velocity mapping were acquired using a black blood segmented κ-space spoiled gradient echo sequence with a temporal resolution of 13.8 ms. Peak systolic and diastolic radial velocities as well as radial velocity curves were obtained for 16 ventricular segments. RESULTS Significant differences among peak radial velocities of basal and mid-ventricular segments have been recorded. Particular patterns of segmental radial velocity curves were also noted. An additional wave of outward radial movement during the phase of rapid ventricular filling, corresponding to the expected timing of the third heart sound, appeared of particular interest. CONCLUSION The technique has allowed visualization of new details of LV radial wall motion. In particular, higher peak systolic radial velocities of anterior and inferior segments are suggestive of a relatively higher dynamics of anteroposterior vs lateral radial motion in systole. Specific patterns of radial motion of other LV segments may provide additional insights into LV mechanics. ADVANCES IN KNOWLEDGE The outward radial movement of LV segments impacted by the blood flow during rapid ventricular filling provides a potential substrate for the third heart sound. A biphasic radial expansion of the basal anteroseptal segment in early diastole is likely to be related to the simultaneous longitudinal LV displacement by the stretched great vessels following repolarization and their close apposition to this segment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Pulmonary hypertension (PH) frequently coexists with severe aortic stenosis, and PH severity has been shown to predict outcomes after transcatheter aortic valve implantation (TAVI). The effect of PH hemodynamic presentation on clinical outcomes after TAVI is unknown. METHODS AND RESULTS Of 606 consecutive patients undergoing TAVI, 433 (71.4%) patients with severe aortic stenosis and a preprocedural right heart catheterization were assessed. Patients were dichotomized according to whether PH was present (mean pulmonary artery pressure, ≥25 mm Hg; n=325) or not (n=108). Patients with PH were further dichotomized by left ventricular end-diastolic pressure into postcapillary (left ventricular end-diastolic pressure, >15 mm Hg; n=269) and precapillary groups (left ventricular end-diastolic pressure, ≤15 mm Hg; n=56). Finally, patients with postcapillary PH were divided into isolated (n=220) and combined (n=49) subgroups according to whether the diastolic pressure difference (diastolic pulmonary artery pressure-left ventricular end-diastolic pressure) was normal (<7 mm Hg) or elevated (≥7 mm Hg). Primary end point was mortality at 1 year. PH was present in 325 of 433 (75%) patients and was predominantly postcapillary (n=269/325; 82%). Compared with baseline, systolic pulmonary artery pressure immediately improved after TAVI in patients with postcapillary combined (57.8±14.1 versus 50.4±17.3 mm Hg; P=0.015) but not in those with precapillary (49.0±12.6 versus 51.6±14.3; P=0.36). When compared with no PH, a higher 1-year mortality rate was observed in both precapillary (hazard ratio, 2.30; 95% confidence interval, 1.02-5.22; P=0.046) and combined (hazard ratio, 3.15; 95% confidence interval, 1.43-6.93; P=0.004) but not isolated PH patients (P=0.11). After adjustment, combined PH remained a strong predictor of 1-year mortality after TAVI (hazard ratio, 3.28; P=0.005). CONCLUSIONS Invasive stratification of PH according to hemodynamic presentation predicts acute response to treatment and 1-year mortality after TAVI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES To validate a self-expanding transcatheter valve for off-pump transatrial mitral valve-in-ring (VIR) implantation via a left thoracotomy. METHODS Mitral valve annuloplasty was performed via sternotomy during cardiopulmonary bypass on 9 pigs. After successful weaning from extracorporal circulation, the custom-made, self-expanding transcatheter VIR device was deployed under fluoroscopic guidance within the annuloplasty ring via a left thoracotomy. Hemodynamic data before and after the implantation were recorded. Mitral annulus diameter and valve area were measured by echocardiography. Transvalvular and left-ventricular outflow-tract pressure gradient were measured invasively. RESULTS Eight successful implantations were performed. Implantation failed in 1 pig because of difficulty with technical delivery of the sheath. Mean transatrial procedure time was 12.6 ± 1.7 min. Hemodynamic status during transatrial implantation was stable, and differences were not statistically significant. Mean mitral annulus diameter and mean mitral orifice area were 2.32 ± 0.2 and 3.84 ± 0.55 cm2, respectively. Mild regurgitation was detected in 7 animals and moderate regurgitation in 1. Mean gradients were 6.1 ± 5.0 mm Hg across the device. Postmortem examination confirmed adequate positioning of devices within the annuloplasty ring. CONCLUSIONS This custom-made transcatheter device allows for safe and reproducible off-pump transatrial mitral VIR implantations. Transatrial access is a promising route to facilitate VIR implantations. Our custom-made stent-valve may be suitable for VIR procedures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE Abnormal ECG findings suggestive of cardiac disease are frequent in patients with funnel chest, although structural heart disease is rare. Electrocardiographic characteristics and changes following new surgical treatments in young adults are not described so far. The aim of the study was to analyze electrocardiographic characteristics of patients with funnel chest before and after minimally invasive funnel chest correction by the Nuss procedure. METHODS Twenty-six patients with surgical correction of funnel chest using pectus bar were included. Twelve-lead ECGs before and later than one year after surgery were analyzed. RESULTS In postoperative ECGs, amplitude of P wave in lead II and negative terminal amplitude of P wave in lead V1 decreased from 0.13 to 0.10mV (p=0.03), and from 0.10 to 0.04mV (p<0.001), respectively. Mean QRS duration decreased from 108ms to 98ms (p=0.003) after correction. A pathological left and right Sokolow-Lyon index was observed in 35% and 23% of patients before, versus 8% (p=0.04) and 0% (p=0.01) after correction, respectively. In contrast, the rate of patients with J wave pattern in precordial leads V4-V6 increased from 8% before to 42% after surgery (p=0.004). CONCLUSIONS ECG abnormalities in patients with funnel chest are frequent, and can normalize after surgical correction by the Nuss procedure. De novo J wave pattern in precordial leads V4-V6 is a frequent finding after surgical funnel chest correction using pectus bar.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Many of the clinical manifestations of hyperthyroidism are due to the ability of thyroid hormones to alter myocardial contractility and cardiovascular hemodynamics, leading to cardiovascular impairment. In contrast, recent studies highlight also the potential beneficial effects of thyroid hormone administration for clinical or preclinical treatment of different diseases such as atherosclerosis, obesity and diabetes or as a new therapeutic approach in demyelinating disorders. In these contexts and in the view of developing thyroid hormone-based therapeutic strategies, it is, however, important to analyze undesirable secondary effects on the heart. Animal models of experimentally induced hyperthyroidism therefore represent important tools for investigating and monitoring changes of cardiac function. In our present study we use high-field cardiac MRI to monitor and follow-up longitudinally the effects of prolonged thyroid hormone (triiodothyronine) administration focusing on murine left ventricular function. Using a 9.4 T small horizontal bore animal scanner, cinematographic MRI was used to analyze changes in ejection fraction, wall thickening, systolic index and fractional shortening. Cardiac MRI investigations were performed after sustained cycles of triiodothyronine administration and treatment arrest in adolescent (8 week old) and adult (24 week old) female C57Bl/6 N mice. Triiodothyronine supplementation of 3 weeks led to an impairment of cardiac performance with a decline in ejection fraction, wall thickening, systolic index and fractional shortening in both age groups but with a higher extent in the group of adolescent mice. However, after a hormonal treatment cessation of 3 weeks, only young mice are able to partly restore cardiac performance in contrast to adult mice lacking this recovery potential and therefore indicating a presence of chronically developed heart pathology.