Electrocardiographic characteristics of patients with funnel chest before and after surgical correction using pectus bar: A new association with precordial J wave pattern.
Data(s) |
2016
|
---|---|
Resumo |
OBJECTIVE Abnormal ECG findings suggestive of cardiac disease are frequent in patients with funnel chest, although structural heart disease is rare. Electrocardiographic characteristics and changes following new surgical treatments in young adults are not described so far. The aim of the study was to analyze electrocardiographic characteristics of patients with funnel chest before and after minimally invasive funnel chest correction by the Nuss procedure. METHODS Twenty-six patients with surgical correction of funnel chest using pectus bar were included. Twelve-lead ECGs before and later than one year after surgery were analyzed. RESULTS In postoperative ECGs, amplitude of P wave in lead II and negative terminal amplitude of P wave in lead V1 decreased from 0.13 to 0.10mV (p=0.03), and from 0.10 to 0.04mV (p<0.001), respectively. Mean QRS duration decreased from 108ms to 98ms (p=0.003) after correction. A pathological left and right Sokolow-Lyon index was observed in 35% and 23% of patients before, versus 8% (p=0.04) and 0% (p=0.01) after correction, respectively. In contrast, the rate of patients with J wave pattern in precordial leads V4-V6 increased from 8% before to 42% after surgery (p=0.004). CONCLUSIONS ECG abnormalities in patients with funnel chest are frequent, and can normalize after surgical correction by the Nuss procedure. De novo J wave pattern in precordial leads V4-V6 is a frequent finding after surgical funnel chest correction using pectus bar. |
Formato |
application/pdf |
Identificador |
http://boris.unibe.ch/75965/1/1-s2.0-S0022073615004252-main.pdf Tanner, Hildegard; Bischof, Désirée; Roten, Laurent; Hoksch, Beatrix; Seiler, Jens; Schmid, Ralph; Delacrétaz, Etienne (2016). Electrocardiographic characteristics of patients with funnel chest before and after surgical correction using pectus bar: A new association with precordial J wave pattern. Journal of Electrocardiology, 49(2), pp. 174-181. Churchill Livingstone 10.1016/j.jelectrocard.2015.12.004 <http://dx.doi.org/10.1016/j.jelectrocard.2015.12.004> doi:10.7892/boris.75965 info:doi:10.1016/j.jelectrocard.2015.12.004 info:pmid:26774549 urn:issn:1532-8430 |
Idioma(s) |
eng |
Publicador |
Churchill Livingstone |
Relação |
http://boris.unibe.ch/75965/ |
Direitos |
info:eu-repo/semantics/restrictedAccess |
Fonte |
Tanner, Hildegard; Bischof, Désirée; Roten, Laurent; Hoksch, Beatrix; Seiler, Jens; Schmid, Ralph; Delacrétaz, Etienne (2016). Electrocardiographic characteristics of patients with funnel chest before and after surgical correction using pectus bar: A new association with precordial J wave pattern. Journal of Electrocardiology, 49(2), pp. 174-181. Churchill Livingstone 10.1016/j.jelectrocard.2015.12.004 <http://dx.doi.org/10.1016/j.jelectrocard.2015.12.004> |
Palavras-Chave | #610 Medicine & health #570 Life sciences; biology |
Tipo |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion PeerReviewed |