35 resultados para time of day


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND The severity of aortic regurgitation can be estimated using pressure half time (PHT) of the aortic regurgitation flow velocity, but the correlation between regurgitant fraction and PHT is weak. AIM To test the hypothesis that the association between PHT and regurgitant fraction is substantially influenced by left ventricular relaxation. METHODS In 63 patients with aortic regurgitation, subdivided into a group without (n = 22) and a group with (n = 41) left ventricular hypertrophy, regurgitant fraction was calculated using the difference between right and left ventricular cardiac outputs. Left ventricular relaxation was assessed using the early to late diastolic Doppler tissue velocity ratio of the mitral annulus (E/ADTI), the E/A ratio of mitral inflow (E/AM), and the E deceleration time (E-DT). Left ventricular hypertrophy was assessed using the M mode derived left ventricular mass index. RESULTS The overall correlation between regurgitant fraction and PHT was weak (r = 0.36, p < 0.005). In patients without left ventricular hypertrophy, there was a significant correlation between regurgitant fraction and PHT (r = 0.62, p < 0.005), but not in patients with left ventricular hypertrophy. In patients with a left ventricular relaxation abnormality (defined as E/ADTI< 1, E/AM< age corrected lower limit, E-DT >/= 220 ms), no associations between regurgitant fraction and PHT were found, whereas in patients without left ventricular relaxation abnormalities, the regurgitant fraction to PHT relations were significant (normal E/AM: r = 0.57, p = 0.02; E-DT< 220 ms: r = 0.50, p < 0.001; E/ADTI < 1: r = 0.57, p = 0.02). CONCLUSIONS Only normal left ventricular relaxation allows a significant decay of PHT with increasing aortic regurgitation severity. In abnormal relaxation, which is usually present in left ventricular hypertrophy, wide variation in prolonged backward left ventricular filling may cause dissociation between the regurgitant fraction and PHT. Thus the PHT method should only be used in the absence of left ventricular relaxation abnormalities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract. The 74 (75) ka Toba eruption in Sumatra, Indonesia, is considered to be one of the largest volcanic events during the Quaternary. Tephra from the Toba eruption has been found in many terrestrial and marine sedimentary deposits, and acidity peaks related to the eruption have been used to synchronize ice core records from Greenland and Antarctica. Seismic profiles and sedimentological data from Lake Prespa on the Balkan Peninsula, SE Europe, indicate a lake level lowstand at 73.6±7.7 ka based on ESR dating of shells. Tephrostratigraphy, radiocarbon dating and tuning of the total organic carbon content with the NGRIP isotope record, corroborate that the lake level lowstand was a short-term event superimposed on the general cooling trend at the end of MIS 5, most likely at the onset of the Greenland Stadial GS- 20. Acknowledging that tectonic events or karst processes could have triggered this lake level lowstand, the chronological correspondence between the lowstand and the Toba eruption is intriguing. Therefore a Toba-driven short-term shift to aridity in the Balkan region, leading to lake level changes and triggering spatial expansion events in one of the lake’s most abundant benthic species, the carino mussel Dreissena presbensis, cannot be excluded.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Key performance features of a miniature laser ablation time-of-flight mass spectrometer designed for in situ investigations of the chemical composition of planetary surfaces are presented. This mass spectrometer is well suited for elemental and isotopic analysis of raw solid materials with high sensitivity and high spatial resolution. In this study, ultraviolet laser radiation with irradiances suitable for ablation (< 1 GW/cm2) is used to achieve stable ion formation and low sample consumption. In comparison to our previous laser ablation studies at infrared wavelengths, several improvements to the experimental setup have been made, which allow accurate control over the experimental conditions and good reproducibility of measurements. Current performance evaluations indicate significant improvements to several instrumental figures of merit. Calibration of the mass scale is performed within a mass accuracy (Δm/m) in the range of 100 ppm, and a typical mass resolution (m/Δm) ~600 is achieved at the lead mass peaks. At lower laser irradiances, the mass resolution is better, about (m/Δm) ~900 for lead, and limited by the laser pulse duration of 3 ns. The effective dynamic range of the instrument was enhanced from about 6 decades determined in previous study up to more than 8 decades at present. Current studies show high sensitivity in detection of both metallic and non-metallic elements. Their abundance down to tens of ppb can be measured together with their isotopic patterns. Due to strict control of the experimental parameters, e.g. laser characteristics, ion-optical parameters and sample position, by computer control, measurements can be performed with high reproducibility. Copyright © 2012 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE We report on workflow and process-based performance measures and their effect on clinical outcome in Solitaire FR Thrombectomy for Acute Revascularization (STAR), a multicenter, prospective, single-arm study of Solitaire FR thrombectomy in large vessel anterior circulation stroke patients. METHODS Two hundred two patients were enrolled across 14 centers in Europe, Canada, and Australia. The following time intervals were measured: stroke onset to hospital arrival, hospital arrival to baseline imaging, baseline imaging to groin puncture, groin puncture to first stent deployment, and first stent deployment to reperfusion. Effects of time of day, general anesthesia use, and multimodal imaging on workflow were evaluated. Patient characteristics and workflow processes associated with prolonged interval times and good clinical outcome (90-day modified Rankin score, 0-2) were analyzed. RESULTS Median times were onset of stroke to hospital arrival, 123 minutes (interquartile range, 163 minutes); hospital arrival to thrombolysis in cerebral infarction (TICI) 2b/3 or final digital subtraction angiography, 133 minutes (interquartile range, 99 minutes); and baseline imaging to groin puncture, 86 minutes (interquartile range, 24 minutes). Time from baseline imaging to puncture was prolonged in patients receiving intravenous tissue-type plasminogen activator (32-minute mean delay) and when magnetic resonance-based imaging at baseline was used (18-minute mean delay). Extracranial carotid disease delayed puncture to first stent deployment time on average by 25 minutes. For each 1-hour increase in stroke onset to final digital subtraction angiography (or TICI 2b/3) time, odds of good clinical outcome decreased by 38%. CONCLUSIONS Interval times in the STAR study reflect current intra-arterial therapy for patients with acute ischemic stroke. Improving workflow metrics can further improve clinical outcome. CLINICAL TRIAL REGISTRATION: URL http://www.clinicaltrials.gov. Unique identifier: NCT01327989.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For the detection of climate change, not only the magnitude of a trend signal is of significance. An essential issue is the time period required by the trend to be detectable in the first place. An illustrative measure for this is time of emergence (ToE), that is, the point in time when a signal finally emerges from the background noise of natural variability. We investigate the ToE of trend signals in different biogeochemical and physical surface variables utilizing a multi-model ensemble comprising simulations of 17 Earth system models (ESMs). We find that signals in ocean biogeochemical variables emerge on much shorter timescales than the physical variable sea surface temperature (SST). The ToE patterns of pCO2 and pH are spatially very similar to DIC (dissolved inorganic carbon), yet the trends emerge much faster – after roughly 12 yr for the majority of the global ocean area, compared to between 10 and 30 yr for DIC. ToE of 45–90 yr are even larger for SST. In general, the background noise is of higher importance in determining ToE than the strength of the trend signal. In areas with high natural variability, even strong trends both in the physical climate and carbon cycle system are masked by variability over decadal timescales. In contrast to the trend, natural variability is affected by the seasonal cycle. This has important implications for observations, since it implies that intra-annual variability could question the representativeness of irregularly sampled seasonal measurements for the entire year and, thus, the interpretation of observed trends.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper investigates empirically the Bolton, Scheinkman, and Xiong (2006) hypothesis, according to which initial shareholders may provide incentives to managers to take actions that stimulate speculative bubbles. We test this hypothesis with data on up to 8,544 directors and up to 1,677 companies between 2004-2008. Using vesting time as a measure of the short-term performance weighting in CEO compensation and various alternative measures of the extent of speculation, the findings support the hypothesis: vesting time decreases with more intensive speculation. The results prove robust in various empirical model specifications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A tightly attached keratinized mucosa around endosseous dental implants is believed to be protective against peri-implant bone loss. Tension caused by buccal frena and mobile non keratinized mucosa is to avoid. This case report documents the optimization of peri-implant mucosal conditions in the upper and lower jaw. At the time of second stage surgery (re-entry) at submucosally osseointegrated dental implants an enlargement of keratinized mucosa and a thickening of soft tissue was obtained administrating a vestibuloplasty combined by a free gingival graft or a vestibuloplasty combined by an apically moved flap.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To analyze the transit time from various locations in the intestines of cows with cecal dilatation-dislocation (CDD), healthy control cows, and cows with left displacement of the abomasum (LDA). ANIMALS 15 cows with naturally occurring CDD (group 1), 14 healthy control cows (group 2), and 18 cows with LDA (group 3). PROCEDURES 5 electronic transmitters were encased in capsules and placed in the lumen of the ileum, cecum, proximal portion of the colon, and 2 locations in the spiral colon (colon 1 and colon 2) and used to measure the transit time (ie, time between placement in the lumen and excretion of the capsules from the rectum). Excretion time of the capsules from each intestinal segment was compared among groups. RESULTS Cows recovered well from surgery, except for 1 cow with relapse of CDD 4 days after surgery and 2 cows with incisional infection. High variability in capsule excretion times was observed for all examined intestinal segments in all groups. Significant differences were detected for the excretion time from the colon (greater in cows with CDD than in healthy control cows) and cecum (less in cows with LDA than in cows of the other 2 groups). CONCLUSIONS AND CLINICAL RELEVANCE The technique developed to measure excretion time of capsules from bovine intestines was safe and reliable; however, the large variability observed for all intestinal segments and all groups would appear to be a limitation for its use in assessment of intestinal transit time of cattle in future studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES Sensorineural hearing loss from sound overexposure has a considerable prevalence. Identification of sound hazards is crucial, as prevention, due to a lack of definitive therapies, is the sole alternative to hearing aids. One subjectively loud, yet little studied, potential sound hazard is movie theaters. This study uses smart phones to evaluate their applicability as a widely available, validated sound pressure level (SPL) meter. Therefore, this study measures sound levels in movie theaters to determine whether sound levels exceed safe occupational noise exposure limits and whether sound levels in movie theaters differ as a function of movie, movie theater, presentation time, and seat location within the theater. DESIGN Six smart phones with an SPL meter software application were calibrated with a precision SPL meter and validated as an SPL meter. Additionally, three different smart phone generations were measured in comparison to an integrating SPL meter. Two different movies, an action movie and a children's movie, were measured six times each in 10 different venues (n = 117). To maximize representativeness, movies were selected focusing on large release productions with probable high attendance. Movie theaters were selected in the San Francisco, CA, area based on whether they screened both chosen movies and to represent the largest variety of theater proprietors. Measurements were analyzed in regard to differences between theaters, location within the theater, movie, as well as presentation time and day as indirect indicator of film attendance. RESULTS The smart phone measurements demonstrated high accuracy and reliability. Overall, sound levels in movie theaters do not exceed safe exposure limits by occupational standards. Sound levels vary significantly across theaters and demonstrated statistically significant higher sound levels and exposures in the action movie compared to the children's movie. Sound levels decrease with distance from the screen. However, no influence on time of day or day of the week as indirect indicator of film attendance could be found. CONCLUSIONS Calibrated smart phones with an appropriate software application as used in this study can be utilized as a validated SPL meter. Because of the wide availability, smart phones in combination with the software application can provide high quantity recreational sound exposure measurements, which can facilitate the identification of potential noise hazards. Sound levels in movie theaters decrease with distance to the screen, but do not exceed safe occupational noise exposure limits. Additionally, there are significant differences in sound levels across movie theaters and movies, but not in presentation time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE The aim of this study was to compare the diagnostic accuracy of 3D time-of-flight (TOF-MRA) and contrast-enhanced (CE-MRA) magnetic resonance angiography at 3 T for detection and quantification of proximal high-grade stenosis using multidetector computed tomography angiography (MDCTA) as reference standard. METHODS The institutional ethics committee approved this prospective study. A total of 41 patients suspected of having internal carotid artery (ICA) stenosis underwent both MDCTA and MRA. CE-MRA and TOF-MRA were performed using a 3.0-T imager with a dedicated eight-element cervical coil. ICA stenoses were measured according to the North American Symptomatic Carotid Endarterectomy Trial criteria and categorized as 0-25 % (minimal), 25-50 % (mild), 50-69 % (moderate), 70-99 % (high grade), and 100 % (occlusion). Sensitivity and specificity for the detection of high-grade ICA stenoses (70-99 %) and ICA occlusions were determined. In addition, intermodality agreement was assessed with κ-statistics for detection of high-grade ICA stenoses (70-99 %) and ICA occlusions. RESULTS A total of 80 carotid arteries of 41 patients were reviewed. Two previously stented ICAs were excluded from analysis. On MDCTA, 7 ICAs were occluded, 12 ICAs presented with and 63 without a high-grade ICA stenosis (70-99 %). For detecting 70-99 % stenosis, both 3D TOF-MRA and CE-MRA were 91.7 % sensitive and 98.5 % specific, respectively. Both MRA techniques were highly sensitive (100 %), and specific (CE-MRA, 100 %; TOF-MRA, 98.7 %) for the detection of ICA occlusion. However, TOF-MRA misclassified one high-grade stenosis as occlusion. Intermodality agreement for detection of 70-99 % ICA stenoses was excellent between TOF-MRA and CE-MRA [κ = 0.902, 95 % confidence interval (CI) = 0.769-1.000], TOF-MRA and MDCTA (κ = 0.902, 95 % CI = 0.769-1.000), and CE-MRA and MDCTA (κ = 0.902, 95 % CI = 0.769-1.000). CONCLUSION Both 3D TOF-MRA and CE-MRA at 3 T are reliable tools for detecting high-grade proximal ICA stenoses (70-99 %). 3D TOF-MRA might misclassify pseudo-occlusions as complete occlusions. If there are no contraindications for CE-MRA, CE-MRA is recommended as primary MR imaging modality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Noble gas analysis in early solar system materials, which can provide valuable information about early solar system processes and timescales, are very challenging because of extremely low noble gas concentrations (ppt). We therefore developed a new compact sized (33 cm length, 7.2cm diameter, 1.3 L internal volume) Time-of-Flight (TOF) noble gas mass spectrometer for high sensitivity. We call it as Edel Gas Time-of-flight (EGT) mass spectrometer. The instrument uses electron impact ionization coupled to an ion trap, which allows us to ionize and measure all noble gas isotopes. Using a reflectron set-up improves the mass resolution. In addition, the reflectron set-up also enables some extra focusing. The detection is via MCPs and the signals are processed either via ADC or TDC systems. The objective of this work is to understand the newly developed Time-Of-Flight (TOF) mass spectrometer for noble gas analysis in presolar grains of the meteorites. Chapter 1 briefly introduces the basic idea and importance of the instrument. The physics relevant to time-of-flight mass spectrometry technique is discussed in the Chapter 2 and Chapter 3 will present the oxidation technique of nanodiamonds of the presolar grains by using copper oxide. Chapter 4 will present the details about EGT data analysis software. Chapter 5 and Chapter 6 will explain the details about EGT design and operation. Finally, the performance results will be presented and discussed in the Chapter 7, and whole work is summarized in Chapter 8 and also outlook of the future work is given.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Whether screening for thrombophilia is useful for patients after a first episode of venous thromboembolism (VTE) is a controversial issue. However, the impact of thrombophilia on the risk of recurrence may vary depending on the patient's age at the time of the first VTE. PATIENTS AND METHODS Of 1221 VTE patients (42 % males) registered in the MAISTHRO (MAin-ISar-THROmbosis) registry, 261 experienced VTE recurrence during a 5-year follow-up after the discontinuation of anticoagulant therapy. RESULTS Thrombophilia was more common among patients with VTE recurrence than those without (58.6 % vs. 50.3 %; p = 0.017). Stratifying patients by the age at the time of their initial VTE, Cox proportional hazards analyses adjusted for age, sex and the presence or absence of established risk factors revealed a heterozygous prothrombin (PT) G20210A mutation (hazard ratio (HR) 2.65; 95 %-confidence interval (CI) 1.71 - 4.12; p < 0.001), homozygosity/double heterozygosity for the factor V Leiden and/or PT mutation (HR 2.35; 95 %-CI 1.09 - 5.07, p = 0.030), and an antithrombin deficiency (HR 2.12; 95 %-CI 1.12 - 4.10; p = 0.021) to predict recurrent VTE in patients aged 40 years or older, whereas lupus anticoagulants (HR 3.05; 95%-CI 1.40 - 6.66; p = 0.005) increased the risk of recurrence in younger patients. Subgroup analyses revealed an increased risk of recurrence for a heterozygous factor V Leiden mutation only in young females without hormonal treatment whereas the predictive value of a heterozygous PT mutation was restricted to males over the age of 40 years. CONCLUSIONS Our data do not support a preference of younger patients for thrombophilia testing after a first venous thromboembolic event.