Assessment of the excretion time of electronic capsules placed in the intestinal lumen of cows with cecal dilatation-dislocation, healthy control cows, and cows with left displacement of the abomasum


Autoria(s): Devaux, David John-Alexander Llewellyn; Lempen, Markus; Schelling, Esther; Koch, Volker M; Meylan, Mireille
Data(s)

01/01/2015

Resumo

OBJECTIVE To analyze the transit time from various locations in the intestines of cows with cecal dilatation-dislocation (CDD), healthy control cows, and cows with left displacement of the abomasum (LDA). ANIMALS 15 cows with naturally occurring CDD (group 1), 14 healthy control cows (group 2), and 18 cows with LDA (group 3). PROCEDURES 5 electronic transmitters were encased in capsules and placed in the lumen of the ileum, cecum, proximal portion of the colon, and 2 locations in the spiral colon (colon 1 and colon 2) and used to measure the transit time (ie, time between placement in the lumen and excretion of the capsules from the rectum). Excretion time of the capsules from each intestinal segment was compared among groups. RESULTS Cows recovered well from surgery, except for 1 cow with relapse of CDD 4 days after surgery and 2 cows with incisional infection. High variability in capsule excretion times was observed for all examined intestinal segments in all groups. Significant differences were detected for the excretion time from the colon (greater in cows with CDD than in healthy control cows) and cecum (less in cows with LDA than in cows of the other 2 groups). CONCLUSIONS AND CLINICAL RELEVANCE The technique developed to measure excretion time of capsules from bovine intestines was safe and reliable; however, the large variability observed for all intestinal segments and all groups would appear to be a limitation for its use in assessment of intestinal transit time of cattle in future studies.

Formato

application/pdf

Identificador

http://boris.unibe.ch/63438/1/ajvr%252E76%252E1%252E60.pdf

Devaux, David John-Alexander Llewellyn; Lempen, Markus; Schelling, Esther; Koch, Volker M; Meylan, Mireille (2015). Assessment of the excretion time of electronic capsules placed in the intestinal lumen of cows with cecal dilatation-dislocation, healthy control cows, and cows with left displacement of the abomasum. American journal of veterinary research, 76(1), pp. 60-69. American Veterinary Medical Association 10.2460/ajvr.76.1.60 <http://dx.doi.org/10.2460/ajvr.76.1.60>

doi:10.7892/boris.63438

info:doi:10.2460/ajvr.76.1.60

info:pmid:25535662

urn:issn:0002-9645

Idioma(s)

eng

Publicador

American Veterinary Medical Association

Relação

http://boris.unibe.ch/63438/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Devaux, David John-Alexander Llewellyn; Lempen, Markus; Schelling, Esther; Koch, Volker M; Meylan, Mireille (2015). Assessment of the excretion time of electronic capsules placed in the intestinal lumen of cows with cecal dilatation-dislocation, healthy control cows, and cows with left displacement of the abomasum. American journal of veterinary research, 76(1), pp. 60-69. American Veterinary Medical Association 10.2460/ajvr.76.1.60 <http://dx.doi.org/10.2460/ajvr.76.1.60>

Palavras-Chave #630 Agriculture #590 Animals (Zoology)
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed