34 resultados para non conventional secretion


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective was to compare the prevalence of subclinical mastitis (SM) and of udder pathogens in 60 Swiss organic (OP) and 60 conventional production systems (CP). Cows (n=970) were studied for SM prevalence and udder pathogens at median 31 d and 102 d post partum. Cows showing a >/=1+ positive California Mastitis Test (CMT) in at least one quarter were considered to have SM. Cow-level prevalences of SM for visits at 31 d and 102 d post partum (39% and 40% in OP and 34% and 35% in CP) were similar, but quarter-level prevalences of SM were higher (P<0.02) in OP than CP (15% and 18% in OP and 12% and 15% in CP). Median somatic cell counts in milk at 31 d post partum were higher (P<0.05) in OP than CP cows (43000 and 28000 cells/ml, respectively), but were similar at 102 d post partum in OP and CP cows (45000 and 38000 cells/ml, respectively). In milk samples from quarters showing a CMT reaction >/=2+ the prevalences of coagulase negative staphylococci were lower (P<0.05) at 102 d post partum, whereas prevalences of non-agalactiae streptococci were higher (P<0.05) in OP than in CP cows at 31 d and 102 d post partum. In conclusion, under Swiss conditions, subclinical mastitis is a greater problem in organic than in conventional production systems, but differences are not marked.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Three different fissure preparation procedures were tested and compared to the non-invasive approach using a conventional unfilled sealant and a flowable composite. Eighty permanent molars were selected and divided into 4 groups of 20 teeth each. All the teeth were split into 2 halves, and the exposed fissures were photographed under a microscope (35x) before and after being prepared using the following methods: (I) Er:YAG laser (KEY Laser, KaVo) 600 mJ pulse energy, 6 Hz; (II) diamond bur; (III) Er: YAG laser (KEY Laser, KaVo) 200 mJ pulse energy, 4 Hz; (IV) Control group: Powder jet cleaner (Prophyflex, KaVo, Germany). The pre-and postimages were superimposed in order to evaluate the amount of hard tissue removed. Ten teeth in each group were then acid etched and sealed with an unfilled sealant (Delton opaque, Dentsply), while the remaining 10 teeth were acid etched, primed and bonded (Prime ; Bond NT, Dentsply) and sealed with a flowable composite (X-flow, DeTrey, Dentsply). Material penetration and microleakage were evaluated after thermocycling (5000 cycles) and staining with methylene blue 5%. ANOVA and Mann-Whitney tests were applied for statistical analysis. The laser 600 mJ and bur eliminated the greatest amount of hard tissue. The control teeth presented the least microleakage when sealed with Delton or X-flow. A correlation between material penetration and microleakage could not be statistically confirmed. Mechanical preparation prior to fissure sealing did not enhance the final performance of the sealant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Patient-ventilator synchrony during non-invasive pressure support ventilation with the helmet device is often compromised when conventional pneumatic triggering and cycling-off were used. A possible solution to this shortcoming is to replace the pneumatic triggering with neural triggering and cycling-off-using the diaphragm electrical activity (EA(di)). This signal is insensitive to leaks and to the compliance of the ventilator circuit. DESIGN: Randomized, single-blinded, experimental study. SETTING: University Hospital. PARTICIPANTS AND SUBJECTS: Seven healthy human volunteers. INTERVENTIONS: Pneumatic triggering and cycling-off were compared to neural triggering and cycling-off during NIV delivered with the helmet. MEASUREMENTS AND RESULTS: Triggering and cycling-off delays, wasted efforts, and breathing comfort were determined during restricted breathing efforts (<20% of voluntary maximum EA(di)) with various combinations of pressure support (PSV) (5, 10, 20 cm H(2)O) and respiratory rates (10, 20, 30 breath/min). During pneumatic triggering and cycling-off, the subject-ventilator synchrony was progressively more impaired with increasing respiratory rate and levels of PSV (p < 0.001). During neural triggering and cycling-off, effect of increasing respiratory rate and levels of PSV on subject-ventilator synchrony was minimal. Breathing comfort was higher during neural triggering than during pneumatic triggering (p < 0.001). CONCLUSIONS: The present study demonstrates in healthy subjects that subject-ventilator synchrony, trigger effort, and breathing comfort with a helmet interface are considerably less impaired during increasing levels of PSV and respiratory rates with neural triggering and cycling-off, compared to conventional pneumatic triggering and cycling-off.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fish behaviourists are increasingly turning to non-invasive measurement of steroid hormones in holding water, as opposed to blood plasma. When some of us met at a workshop in Faro, Portugal, in September, 2007, we realised that there were still many issues concerning the application of this procedure that needed resolution, including: Why do we measure release rates rather than just concentrations of steroids in the water? How does one interpret steroid release rates when dealing with fish of different sizes? What are the merits of measuring conjugated as well as free steroids in water? In the ‘static’ sampling procedure, where fish are placed in a separate container for a short period of time, does this affect steroid release—and, if so, how can it be minimised? After exposing a fish to a behavioural stimulus, when is the optimal time to sample? What is the minimum amount of validation when applying the procedure to a new species? The purpose of this review is to attempt to answer these questions and, in doing so, to emphasize that application of the non-invasive procedure requires more planning and validation than conventional plasma sampling. However, we consider that the rewards justify the extra effort.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

MicroRNAs (miRNAs) constitute a growing class of non-coding RNAs that are thought to regulate gene expression by translational repression. Several miRNAs in animals exhibit tissue-specific or developmental-stage-specific expression, indicating that they could play important roles in many biological processes. To study the role of miRNAs in pancreatic endocrine cells we cloned and identified a novel, evolutionarily conserved and islet-specific miRNA (miR-375). Here we show that overexpression of miR-375 suppressed glucose-induced insulin secretion, and conversely, inhibition of endogenous miR-375 function enhanced insulin secretion. The mechanism by which secretion is modified by miR-375 is independent of changes in glucose metabolism or intracellular Ca2+-signalling but correlated with a direct effect on insulin exocytosis. Myotrophin (Mtpn) was predicted to be and validated as a target of miR-375. Inhibition of Mtpn by small interfering (si)RNA mimicked the effects of miR-375 on glucose-stimulated insulin secretion and exocytosis. Thus, miR-375 is a regulator of insulin secretion and may thereby constitute a novel pharmacological target for the treatment of diabetes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Phagocytosis of fine particles (1 mum) by macrophages is a ligand-receptor-mediated, actin-based process, whereas the entering of smaller particles (conventional phagocytosis and by actin-independent mechanisms. Further, they can penetrate the airway barrier and reach resident dendritic cells. Therefore, virosomes are promising vaccine candidates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: A precise, non-invasive, non-toxic, repeatable, convenient and inexpensive follow-up of renal transplants, especially following biopsies, is in the interest of nephrologists. Formerly, the rate of biopsies leading to AV fistulas had been underestimated. Imaging procedures suited to a detailed judgement of these vascular malformations are to be assessed. METHODS: Three-dimensional (3D) reconstruction techniques of ultrasound flow-directed and non-flow-directed energy mode pictures were compared with a standard procedure, gadolinium-enhanced nuclear magnetic resonance imaging angiography (MRA) using the phase contrast technique. RESULTS: Using B-mode and conventional duplex information, AV fistulas were localized in the upper pole of the kidney transplant of the index patient. The 3D reconstruction provided information about the exact localization and orientation of the fistula in relation to other vascular structures, and the flow along the fistula. The MRA provided localization and orientation information, but less functional information. Flow-directed and non-flow-directed energy mode pictures could be reconstructed to provide 3D information about vascular malformations in transplanted kidneys. CONCLUSION: In transplanted kidneys, 3D-ultrasound angiography may be equally as effective as MRA in localizing and identifying AV malformations. Advantages of the ultrasound method are that it is cheaper, non-toxic, non-invasive, more widely availability and that it even provides more functional information. Future prospective studies will be necessary to evaluate the two techniques further.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Strains of Actinobacillus porcitonsillarum are regularly isolated from the tonsils of healthy pigs. A. porcitonsillarum is non pathogenic but phenotypically it strongly resembles the pathogenic species Actinobacillus pleuropneumoniae, thereby interfering with the diagnosis of the latter. A. porcitonsillarum is hemolytic but unlike A. pleuropneumoniae, it contains only apxII genes and not apxI or apxIII genes. In contrast to the truncated apxII operon of A. pleuropneumoniae, which lacks the type I secretion genes BD, characterization of the apxII operon in A. porcitonsillarum revealed that it contains an intact and complete apxII operon. This shows a typical RTX operon structure with the gene arrangement apxIICABD. The region upstream of the apxII operon is also different from that in A. pleuropneumoniae and contains an additional gene, aspC, encoding a putative aspartate aminotransferase. Trans-complementation experiments in Escherichia coli and A. pleuropneumoniae indicated that the entire apxII operon of A. porcitonsillarum is sufficient to express and secrete the ApxIIA toxin and that the ApxIIA toxin of A. pleuropneumoniae can be secreted by the type I secretion system encoded by apxIIBD. These findings suggest that the complete apxII operon found in A. porcitonsillarum might be an ancestor of the truncated homologue found in A. pleuropneumoniae. The genetic context of the apxII locus in A. porcitonsillarum and A. pleuropneumoniae suggests that in the latter, the contemporary truncated operon is the result of a recombination event within the species, rather than a horizontal transfer of an incomplete operon.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Type III secretion systems of Gram-negative bacteria are specific export machineries for virulence factors which allow their translocation to eukaryotic cells. Since they correlate with bacterial pathogenicity, their presence is used as a general indicator of bacterial virulence. By comparing the genetic relationship of the major type III secretion systems we found the family of genes encoding the inner-membrane channel proteins represented by the Yersinia enterocolitica lcrD (synonym yscV) and its homologous genes from other species an ideal component for establishing a general detection approach for type III secretion systems. Based on the genes of the lcrD family we developed gene probes for Gram-negative human, animal and plant pathogens. The probes comprise lcrD from Y. enterocolitica, sepA from enteropathogenic Escherichia coli, invA from Salmonella typhimurium, mxiA from Shigella sonnei, as well as hrcV from Erwinia amylovora. In addition we included as a control probe the flhA gene from E. coli K-12 to validate our approach. FlhA is part of the flagellar export apparatus which shows a high degree of similarity with type III secretions systems, but is not involved in pathogenicity. The probes were evaluated by screening a series of pathogenic as well as non-pathogenic bacteria. The probes detected type III secretion in pathogens where such systems were either known or were expected to be present, whereas no positive hybridization signals could be found in non-pathogenic Gram-negative bacteria. Gram-positive bacteria were devoid of known type III secretion systems. No interference due to the genetic similarity between the type III secretion system and the flagellar export apparatus was observed. However, potential type III secretion systems could be detected in bacteria where no such systems have been described yet. The presented approach provides therefore a useful tool for the assessment of the virulence potential of bacterial isolates of human, animal and plant origin. Moreover, it is a powerful means for a first safety assessment of poorly characterized strains intended to be used in biotechnological applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

STUDY QUESTION Is the steroid hormone profile in follicular fluid (FF) at the time of oocyte retrieval different in naturally matured follicles, as in natural cycle IVF (NC-IVF), compared with follicles stimulated with conventional gonadotrophin stimulated IVF (cIVF)? SUMMARY ANSWER Anti-Mullerian hormone (AMH), testosterone (T) and estradiol (E2) concentrations are ∼3-fold higher, androstenedione (A2) is ∼1.5-fold higher and luteinizing hormone (LH) is ∼14-fold higher in NC-IVF than in cIVF follicles, suggesting an alteration of the follicular metabolism in conventional gonadotrophin stimulated IVF. WHAT IS KNOWN ALREADY In conventional IVF, the implantation rate of unselected embryos appears to be lower than in NC-IVF, which is possibly due to negative effects of the stimulation regimen on follicular metabolism. In NC-IVF, the intrafollicular concentration of AMH has been shown to be positively correlated with the oocyte fertilization and implantation rates. Furthermore, androgen treatment seems to improve the ovarian response in low responders. STUDY DESIGN, SIZE, DURATION This cross-sectional study involving 36 NC-IVF and 40 cIVF cycles was performed from 2011 to 2013. Within this population, 13 women each underwent 1 NC-IVF and 1 cIVF cycle. cIVF was performed by controlled ovarian stimulation with HMG and GnRH antagonists. PARTICIPANTS/MATERIALS, SETTING, METHODS Follicular fluid was collected from the leading follicles. AMH, T, A2, dehydroepiandrosterone (DHEA), E2, FSH, LH and progesterone (P) were determined by immunoassays in 76 women. Aromatase activity in follicular fluid cells was analysed by a tritiated water release assay in 33 different women. For statistical analysis, the non-parametric Mann-Whitney U or Wilcoxon tests were used. MAIN RESULTS AND ROLE OF CHANCE In follicular fluid from NC-IVF and from cIVF, median levels were 32.8 and 10.7 pmol/l for AMH (P < 0.0001), 47.2 and 18.8 µmol/l for T (P < 0.0001), 290 and 206 nmol/l for A2 (P = 0.0035), 6.7 and 5.6 pg/ml for DHEA (n.s.), 3292 and 1225 nmol/l for E2 (P < 0.0001), 4.9 and 7.2 mU/ml for FSH (P < 0.05), 14.4 and 0.9 mU/ml for LH (P < 0.0001) and 62 940 and 54 710 nmol/l for P (n.s.), respectively. Significant differences in follicular fluid concentrations for AMH, E2 and LH were also found in the 13 patients who underwent both NC-IVF and cIVF when they were analysed separately in pairs. Hormone analysis in serum excluded any relevant impact of AMH, T, A2, and E2 serum concentration on the follicular fluid hormone concentrations. Median serum concentrations were 29.4 and 0.9 mU/ml for LH (P < 0.0001) and 2.7 and 23.5 nmol/l for P (P < 0.0001) after NC-IVF and c-IVF, respectively. Positive correlations were seen for FF-AMH with FF-T (r = 0.35, P = 0.0002), FF-T with FF-LH (r = 0.48, P < 0.0001) and FF-E2 with FF-T (r = 0.75, P < 0.0001). The analysis of aromatase activity was not different in NC-IVF and cIVF follicular cells. LIMITATION, REASONS FOR CAUTION Any association between the hormone concentrations and the implantation potential of the oocytes could not be investigated as the oocytes in cIVF were not treated individually in the IVF laboratory. Since both c-IVF and NC-IVF follicles were stimulated by hCG before retrieval, the endocrine milieu in the natural cycle does not represent the pure physiological situation. WIDER IMPLICATIONS OF THE FINDINGS The endocrine follicular milieu and the concentration of putative markers of oocyte quality, such as AMH, are significantly different in gonadotrophin-stimulated conventional IVF compared with natural cycle IVF. This could be a cause for the suggested lower oocyte quality in cIVF compared with naturally matured oocytes. The reasons for the reduced AMH concentration might be low serum and follicular fluid LH concentrations due to LH suppression, leading initially to low follicular androgen concentrations and then to low follicular AMH production. STUDY FUNDING/COMPETING INTERESTS Funding for this study was obtained from public universities (for salaries) and private industry (for consumables). Additionally, the study was supported by an unrestricted grant from MSD Merck Sharp & Dohme GmbH and IBSA Institut Biochimique SA. The authors are clinically involved in low-dose monofollicular stimulation and IVF therapies, using gonadotrophins from all gonadotrophin distributors on the Swiss market, including Institut Biochimique SA and MSD Merck Sharp & Dohme GmbH. Otherwise, the authors have no competing interests. TRIAL REGISTRATION NUMBER Not applicable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM To investigate age- and gender-related differences in non-culprit versus culprit coronary vessels assessed with virtual histology intravascular ultrasound (VH-IVUS). METHODS In 390 patients referred for coronary angiography to a single center (Luzerner Kantonsspital, Switzerland) between May 2007 and January 2011, 691 proximal vessel segments in left anterior descending, circumflex and/or right coronary arteries were imaged by VH-IVUS. Plaque burden and plaque composition (fibrous, fibro-fatty, necrotic core and dense calcium volumes) were analyzed in 3 age tertiles, according to gender and separated for vessels containing non-culprit or culprit lesions. To classify as vessel containing a culprit lesion, the patient had to present with an acute coronary syndrome, and the VH-IVUS had to be performed in a vessel segment containing the culprit lesion according to conventional coronary angiography. RESULTS In non-culprit vessels the plaque burden increased significantly with aging (in men from 37% ± 12% in the lowest to 46% ± 10% in the highest age tertile, P < 0.001; in women from 30% ± 9% to 40% ± 11%, P < 0.001); men had higher plaque burden than women at any age (P < 0.001 for each of the 3 age tertiles). In culprit vessels of the lowest age tertile, plaque burden was significantly higher than that in non-culprit vessels (in men 48% ± 6%, P < 0.001 as compared to non-culprit vessels; in women 44% ± 18%, P = 0.004 as compared to non-culprit vessels). Plaque burden of culprit vessels did not significantly change during aging (plaque burden in men of the highest age tertile 51% ± 9%, P = 0.523 as compared to lowest age tertile; in women of the highest age tertile 49% ± 8%, P = 0.449 as compared to lowest age tertile). In men, plaque morphology of culprit vessels became increasingly rupture-prone during aging (increasing percentages of necrotic core and dense calcium), whereas plaque morphology in non-culprit vessels was less rupture-prone and remained constant during aging. In women, necrotic core in non-culprit vessels was very low at young age, but increased during aging resulting in a plaque morphology that was very similar to men. Plaque morphology in culprit vessels of young women and men was similar. CONCLUSION This study provides evidence that age- and gender-related differences in plaque burden and plaque composition significantly depend on whether the vessel contained a non-culprit or culprit lesion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: A clinically relevant bleeding diathesis is a frequent diagnostic challenge, which sometimes remains unexplained despite extensive investigations. The aim of our work was to evaluate the diagnostic utility of functional platelet testing by flow cytometry in this context. Methods: In case of negative results after standard laboratory work-up, flow cytometric analysis (FCA) of platelet function was done. We performed analysis of surface glycoproteins (GP) Ibα, IIb, IIIa; P-selectin expression and PAC-1 binding after graded doses of ADP, collagen and thrombin; content/secretion of dense granules; ability to generate procoagulant platelets. Results: Out of 437 patients investigated with standard tests between January 2007 and December 2011, we identified 67 (15.3%) with high bleeding scores and non-diagnostic standard laboratory work-up including platelet aggregation studies. Among these patients FCA revealed some potentially causative platelet defects: decreased dense-granule content/secretion (n=13); decreased alpha-granule secretion induced by ADP (n=10), convulxin (n=4) or thrombin (n=3); decreased fibrinogen-receptor activation induced by ADP (n=11), convulxin (n=11) or thrombin (n=8); decreased generation of COAT-platelets, i.e. highly procoagulant platelets induced by simultaneous activation with collagen and thrombin (n=16). Conclusion: Our work confirms that storage pool defects are frequent in patients with a bleeding diathesis and normal coagulation and platelet aggregations studies. Additionally, flow cytometric analysis is able to identify discrete platelet activation defects. In particular, we show for the first time that a relevant proportion of these patients has an isolated impaired ability to generate COAT-platelets - a conceptually new defect in platelet procoagulant activity, that is missed by conventional laboratory work-up. © 2014 Clinical Cytometry Society.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Nebulized surfactant therapy has been proposed as an alternative method of surfactant administration. The use of a perforated vibrating membrane nebulizer provides a variety of advantages over conventional nebulizers. We investigated the molecular structure and integrity of poractant alfa pre- and post-nebulization. METHOD Curosurf® was nebulized using an Investigational eFlow® Nebulizer System. Non-nebulized surfactant ("NN"), recollected surfactant droplets from nebulization through an endotracheal tube ("NT") and nebulization of surfactant directly onto a surface ("ND") were investigated by transmission electron microscopy. Biophysical characteristics were assessed by the Langmuir-Wilhelmy balance and the Captive Bubble Surfactometer. RESULTS Volume densities of lamellar body-like forms (LBL) and multi-lamellar forms (ML) were high for "NN" and "NT" samples (38.8% vs. 47.7% for LBL and 58.2% vs. 47.8% for ML). In the "ND" sample, we found virtually no LBL's, ML's (72.6%) as well as uni-lamellar forms (16.4%) and a new structure, the "garland-like" forms (9.4%). Surface tension for "NN" and "NT" was 23.33 ± 0.29 and 25.77 ± 1.12 mN/m, respectively. Dynamic compression-expansion cycling minimum surface tensions were between 0.91 and 1.77 mN/m. CONCLUSION The similarity of surfactant characteristics of nebulized surfactant via a tube and the non-nebulized surfactant suggests that vibrating membrane nebulizers are suitable for surfactant nebulization. Alterations in surfactant morphology and characteristics after nebulization were transient. A new structural subtype of surfactant was identified. Pediatr Pulmonol. 2014; 49:348-356. © 2013 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND/AIMS Clinical differentiation between organic hypersomnia and non-organic hypersomnia (NOH) is challenging. We aimed to determine the diagnostic value of sleepiness and performance tests in patients with excessive daytime sleepiness (EDS) of organic and non-organic origin. METHODS We conducted a retrospective comparison of the multiple sleep latency test (MSLT), pupillography, and the Steer Clear performance test in three patient groups complaining of EDS: 19 patients with NOH, 23 patients with narcolepsy (NAR), and 46 patients with mild to moderate obstructive sleep apnoea syndrome (OSAS). RESULTS As required by the inclusion criteria, all patients had Epworth Sleepiness Scale (ESS) scores >10. The mean sleep latency in the MSLT indicated mild objective sleepiness in NOH (8.1 ± 4.0 min) and OSAS (7.2 ± 4.1 min), but more severe sleepiness in NAR (2.5 ± 2.0 min). The difference between NAR and the other two groups was significant; the difference between NOH and OSAS was not. In the Steer Clear performance test, NOH patients performed worst (error rate = 10.4%) followed by NAR (8.0%) and OSAS patients (5.9%; p = 0.008). The difference between OSAS and the other two groups was significant, but not between NOH and NAR. The pupillary unrest index was found to be highest in NAR (11.5) followed by NOH (9.2) and OSAS (7.4; n.s.). CONCLUSION A high error rate in the Steer Clear performance test along with mild sleepiness in an objective sleepiness test (MSLT) in a patient with subjective sleepiness (ESS) is suggestive of NOH. This disproportionately high error rate in NOH may be caused by factors unrelated to sleep pressure, such as anergia, reduced attention and motivation affecting performance, but not conventional sleepiness measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND The assessment of hemodynamic status is a crucial task in the initial evaluation of trauma patients. However, blood pressure and heart rate are often misleading, as multiple variables may impact these conventional parameters. More reliable methods such as pulmonary artery thermodilution for cardiac output measuring would be necessary, but its applicability in the Emergency Department is questionable due to their invasive nature. Non-invasive cardiac output monitoring devices may be a feasible alternative. METHODS A systematic literature review was conducted. Only studies that explicitly investigated non-invasive hemodynamic monitoring devices in trauma patients were considered. RESULTS A total of 7 studies were identified as suitable and were included into this review. These studies evaluated in a total of 1,197 trauma patients the accuracy of non-invasive hemodynamic monitoring devices by comparing measurements to pulmonary artery thermodilution, which is the gold standard for cardiac output measuring. The correlation coefficients r between the two methods ranged from 0.79 to 0.92. Bias and precision analysis ranged from -0.02 +/- 0.78 l/min/m(2) to -0.14 +/- 0.73 l/min/m(2). Additionally, data on practicality, limitations and clinical impact of the devices were collected. CONCLUSION The accuracy of non-invasive cardiac output monitoring devices in trauma patients is broadly satisfactory. As the devices can be applied very early in the shock room or even preclinically, hemodynamic shock may be recognized much earlier and therapeutic interventions could be applied more rapidly and more adequately. The devices can be used in the daily routine of a busy ED, as they are non-invasive and easy to master.