Nebulizing poractant alfa versus conventional instillation: Ultrastructural appearance and preservation of surface activity.


Autoria(s): Minocchieri, Stefan; Knoch, Stephan Florian; Schoel, W. Michael; Ochs, Matthias; Nelle, Mathias
Data(s)

01/04/2014

Resumo

BACKGROUND Nebulized surfactant therapy has been proposed as an alternative method of surfactant administration. The use of a perforated vibrating membrane nebulizer provides a variety of advantages over conventional nebulizers. We investigated the molecular structure and integrity of poractant alfa pre- and post-nebulization. METHOD Curosurf® was nebulized using an Investigational eFlow® Nebulizer System. Non-nebulized surfactant ("NN"), recollected surfactant droplets from nebulization through an endotracheal tube ("NT") and nebulization of surfactant directly onto a surface ("ND") were investigated by transmission electron microscopy. Biophysical characteristics were assessed by the Langmuir-Wilhelmy balance and the Captive Bubble Surfactometer. RESULTS Volume densities of lamellar body-like forms (LBL) and multi-lamellar forms (ML) were high for "NN" and "NT" samples (38.8% vs. 47.7% for LBL and 58.2% vs. 47.8% for ML). In the "ND" sample, we found virtually no LBL's, ML's (72.6%) as well as uni-lamellar forms (16.4%) and a new structure, the "garland-like" forms (9.4%). Surface tension for "NN" and "NT" was 23.33 ± 0.29 and 25.77 ± 1.12 mN/m, respectively. Dynamic compression-expansion cycling minimum surface tensions were between 0.91 and 1.77 mN/m. CONCLUSION The similarity of surfactant characteristics of nebulized surfactant via a tube and the non-nebulized surfactant suggests that vibrating membrane nebulizers are suitable for surfactant nebulization. Alterations in surfactant morphology and characteristics after nebulization were transient. A new structural subtype of surfactant was identified. Pediatr Pulmonol. 2014; 49:348-356. © 2013 Wiley Periodicals, Inc.

Formato

application/pdf

Identificador

http://boris.unibe.ch/50248/1/ppul22838.pdf

Minocchieri, Stefan; Knoch, Stephan Florian; Schoel, W. Michael; Ochs, Matthias; Nelle, Mathias (2014). Nebulizing poractant alfa versus conventional instillation: Ultrastructural appearance and preservation of surface activity. Pediatric pulmonology, 49(4), pp. 348-356. Wiley-Blackwell 10.1002/ppul.22838 <http://dx.doi.org/10.1002/ppul.22838>

doi:10.7892/boris.50248

info:doi:10.1002/ppul.22838

info:pmid:24039226

urn:issn:8755-6863

Idioma(s)

eng

Publicador

Wiley-Blackwell

Relação

http://boris.unibe.ch/50248/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Minocchieri, Stefan; Knoch, Stephan Florian; Schoel, W. Michael; Ochs, Matthias; Nelle, Mathias (2014). Nebulizing poractant alfa versus conventional instillation: Ultrastructural appearance and preservation of surface activity. Pediatric pulmonology, 49(4), pp. 348-356. Wiley-Blackwell 10.1002/ppul.22838 <http://dx.doi.org/10.1002/ppul.22838>

Palavras-Chave #500 Science #610 Medicine & health
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion