Decreased generation of procoagulant platelets detected by flow cytometric analysis in patients with bleeding diathesis


Autoria(s): Daskalakis, Michael; Colucci, Giuseppe; Keller, Peter; Rochat, Sophie; Silzle, Tobias; Demarmels Biasiutti, Franziska; Barizzi, Gabriela; Alberio, Lorenzo
Data(s)

24/01/2014

Resumo

Background: A clinically relevant bleeding diathesis is a frequent diagnostic challenge, which sometimes remains unexplained despite extensive investigations. The aim of our work was to evaluate the diagnostic utility of functional platelet testing by flow cytometry in this context. Methods: In case of negative results after standard laboratory work-up, flow cytometric analysis (FCA) of platelet function was done. We performed analysis of surface glycoproteins (GP) Ibα, IIb, IIIa; P-selectin expression and PAC-1 binding after graded doses of ADP, collagen and thrombin; content/secretion of dense granules; ability to generate procoagulant platelets. Results: Out of 437 patients investigated with standard tests between January 2007 and December 2011, we identified 67 (15.3%) with high bleeding scores and non-diagnostic standard laboratory work-up including platelet aggregation studies. Among these patients FCA revealed some potentially causative platelet defects: decreased dense-granule content/secretion (n=13); decreased alpha-granule secretion induced by ADP (n=10), convulxin (n=4) or thrombin (n=3); decreased fibrinogen-receptor activation induced by ADP (n=11), convulxin (n=11) or thrombin (n=8); decreased generation of COAT-platelets, i.e. highly procoagulant platelets induced by simultaneous activation with collagen and thrombin (n=16). Conclusion: Our work confirms that storage pool defects are frequent in patients with a bleeding diathesis and normal coagulation and platelet aggregations studies. Additionally, flow cytometric analysis is able to identify discrete platelet activation defects. In particular, we show for the first time that a relevant proportion of these patients has an isolated impaired ability to generate COAT-platelets - a conceptually new defect in platelet procoagulant activity, that is missed by conventional laboratory work-up. © 2014 Clinical Cytometry Society.

Formato

application/pdf

Identificador

http://boris.unibe.ch/48149/1/10.1002cytob.21157.pdf

Daskalakis, Michael; Colucci, Giuseppe; Keller, Peter; Rochat, Sophie; Silzle, Tobias; Demarmels Biasiutti, Franziska; Barizzi, Gabriela; Alberio, Lorenzo (2014). Decreased generation of procoagulant platelets detected by flow cytometric analysis in patients with bleeding diathesis. Cytometry. Part B, Clinical cytometry, n/a-n/a. Wiley 10.1002/cytob.21157 <http://dx.doi.org/10.1002/cytob.21157>

doi:10.7892/boris.48149

info:doi:10.1002/cytob.21157

info:pmid:24458871

urn:issn:1552-4949

Idioma(s)

eng

Publicador

Wiley

Relação

http://boris.unibe.ch/48149/

Direitos

info:eu-repo/semantics/openAccess

Fonte

Daskalakis, Michael; Colucci, Giuseppe; Keller, Peter; Rochat, Sophie; Silzle, Tobias; Demarmels Biasiutti, Franziska; Barizzi, Gabriela; Alberio, Lorenzo (2014). Decreased generation of procoagulant platelets detected by flow cytometric analysis in patients with bleeding diathesis. Cytometry. Part B, Clinical cytometry, n/a-n/a. Wiley 10.1002/cytob.21157 <http://dx.doi.org/10.1002/cytob.21157>

Palavras-Chave #610 Medicine & health
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed