25 resultados para nano-apatite


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Implementing the plasma-lasing potential for tabletop nano-imaging on across a hot plasma medium drives short-wavelength lasing, promising for "turnkey" nano-imaging setups. A systematic study of the illumination characteristics, combined with design-adapted objectives, is presented. It is shown how the ultimate nano-scale feature is dictated by either the diffraction-limited or the wavefront-limited resolution, which imposed a combined study of both the source and the optics. For nano-imaging, the spatial homogeneity of the illumination (spot noise) was shown as critical. Plasma-lasing from a triple grazing-incidence pumping scheme compensated for the missing spot homogeneity in classical schemes. We demonstrate that a collimating mirror pre-conditions both the pointing stability and the divergence below half a mrad.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the fabrication and field emission properties of high-density nano-emitter arrays with on-chip electron extraction gate electrodes and up to 106 metallic nanotips that have an apex curvature radius of a few nanometers and a the tip density exceeding 108 cm−2. The gate electrode was fabricated on top of the nano-emitter arrays using a self-aligned polymer mask method. By applying a hot-press step for the polymer planarization, gate–nanotip alignment precision below 10 nm was achieved. Fabricated devices exhibited stable field electron emission with a current density of 0.1 A cm−2, indicating that these are promising for applications that require a miniature high-brightness electron source.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser pulses are largely used for processing and analysis of materials and in particular for nano-particle synthesis. This paper addresses fundamentals of the generation of nano-materials following specific thermodynamic paths of the irradiated material. Computer simulations using the hydro code MULTI and the SESAME equation of state have been performed to follow the dynamics of a target initially heated by a short laser pulse over a distance comparable to the metal skin depth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Recent technical development allows the digital manufacturing of monolithic reconstructions with high-performance materials. For implant-supported crowns, the fixation requires an abutment design onto which the reconstruction can be bonded. PURPOSE The aim of this laboratory investigation was to analyze stiffness, strength, and failure modes of implant-supported, computer-assisted design and computer-aided manufacturing (CAD/CAM)-generated resin nano ceramic (RNC) crowns bonded to three different titanium abutments. MATERIALS AND METHODS Eighteen monolithic RNC crowns were produced and loaded in a universal testing machine under quasi-static condition according to DIN ISO 14801. With regard to the type of titanium abutment, three groups were defined: (1) prefabricated cementable standard; (2) CAD/CAM-constructed individualized; and (3) novel prefabricated bonding base. Stiffness and strength were measured and analyzed statistically with Wilcoxon rank sum test. Sections of the specimens were examined microscopically. RESULTS Stiffness demonstrated high stability for all specimens loaded in the physiological loading range with means and standard deviations of 1,579 ± 120 N/mm (group A), 1,733 ± 89 N/mm (group B), and 1,704 ± 162 N/mm (group C). Mean strength of the novel prefabricated bonding base (group C) was 17% lower than of the two other groups. Plastic deformations were detectable for all implant-abutment crown connections. CONCLUSIONS Monolithic implant crowns made of RNC seem to represent a feasible and stable prosthetic construction under laboratory testing conditions with strength higher than the average occlusal force, independent of the different abutment designs used in this investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to constrain the salinity of subduction zone fluids, piston-cylinder experiments have been conducted to investigate the partitioning behaviour of Cl and F in subducted sediments. These experiments were performed at H2O-undersaturated conditions with a synthetic pelite starting composition containing 800 ppm Cl, over a pressure and temperature range of 2.5–4.5 GPa and 630–900 °C. Repetitive experiments were conducted with 1900 ppm Cl + 1000 ppm F, and 2100 ppm Cl. Apatite represents the most Cl-abundant mineral phase, with Cl concentration varying in the range 0.1–2.82 wt%. Affinity for Cl decreases over the following sequence: aqueous fluid > apatite ⩾ melt > other hydrous minerals (phengite, biotite and amphibole). It was found that addition of F to the Cl-bearing starting composition significantly lowers the Cl partition coefficients between apatite and melt (DClAp–melt) and apatite and aqueous fluid (DClAp–aq). Cl–OH exchange coefficients between apatite and melt (KdCl–OHAp–melt) and apatite and aqueous fluid (KdCl–OHAp–aq) were subsequently calculated. KdCl–OHAp–melt was found to vary from 1 to 58, showing an increase with temperature and a decrease with pressure and displaying a regular decrease with increasing H2O content in melt. Mole fractions of Cl and OH in melt were calculated based on an ideal mixing model for H2O, OH, O, Cl and F. The Cl contents of other hydrous minerals (phengite, biotite and amphibole) fall between 200 and 800 ppm, with resultant Cl partition coefficients from 0.02 to 0.49, appearing independent of the bulk Cl and F content. Preliminary data from this study show that the partitioning behaviour of F is strongly in favour of apatite relative to melt and phengite, with DFAp–melt = 15–51. Apatites from representative eclogite facies metasediments were examined and found to have low Cl contents close to ∼100 ppm. Calculations using our experimentally determined KdCl–OHAp–aq of 0.004 at 2.5 GPa, 630 °C indicate a low salinity character (0.5–2 wt% NaCleq) for the fluid formed during dehydration of subducted oceanic sediment at ∼80 km depth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Grey and white carbonate mylonites were collected along thrust planes of the Helvetic Alps. They are characterised by very small grain sizes and non-random grain shape (SPO) and crystallographic preferred orientation (CPO). Presumably they deformed in the field of grain size sensitive flow by recrystallisation accommodated intracrystalline deformation in combination with granular flow. Both mylonites show a similar mean grain size, but in the grey mylonites the grain size range is larger, the grain shapes are more elongate and the dynamically recrystallised calcite grains are more often twinned. Grey mylonites have an oblique CPO, while the CPO in white mylonites is symmetric with respect to the shear plane. Combustion analysis and TEM investigations revealed that grey mylonites contain a higher amount of highly structured kerogens with particle sizes of a few tens of nanometers, which are finely dispersed at the grain boundaries. During deformation of the rock, nano-scale particles reduced the migration velocity of grain boundaries by Zener drag resulting in slower recrystallisation rates of the calcite aggregate. In the grey mylonites, more strain increments were accommodated by individual grains before they became refreshed by dynamic recrystallisation than in white mylonites, where grain boundary migration was less hindered and recrystallisation cycles were faster. Consequently, grey mylonites represent ‘deformation’ microfabrics while white mylonites are characterised by ‘recrystallisation’ microfabrics. Field geologists must utilise this different deformation behavior when applying the obliquity in CPO and SPO of the respective mylonites as reliable shear sense indicators.