84 resultados para New Year sermons.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The PAS-Port system (Cardica, Inc, Redwood City, CA) was used routinely for patients undergoing coronary surgery with at least one venous graft. Graft patency and clinical results were evaluated, respectively, at 6 months and 5 years after surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims: The current study reports clinical outcomes at three year follow-up of the LEADERS clinical trial which was the first all-comers trial comparing a new generation biodegradable polymer biolimus drug-eluting stent (BES) with the first generation permanent polymer sirolimus-eluting stent (SES). Methods and results: One thousand seven hundred and seven patients were randomised to unrestricted use of BES (n=857) or SES (n=850) in an all-comers population. Three year follow-up was available in 95% of the patients, 812 treated with BES and 809 treated with SES. At three years, BES remains non-inferior to SES for the primary endpoint of major adverse cardiac events (composite of cardiac death, myocardial infarction (MI), or clinically-indicated target vessel revascularisation (CI-TVR) (BES 15.7% versus SES 19%; HR 0.82 CI 0.65-1.03; p=0.09). The MACE Kaplan Meier event curves increasingly diverge with the difference in events increasing from 1.4% to 2.4% and 3.3% at 1, 2 and 3 years, respectively in favour of BES. The rate of cardiac death was non-significantly lower 4.2% versus 5.2% (HR=0.81 CI 0.52-1.26; p=0.34) and the rate of myocardial infarction was equivalent 7.2% versus 7.1% (HR 1.01 CI 0.70-1.44; p=0.97) for BES versus SES, respectively. Thus BES was non-inferior to SES in all the safety endpoints. Clinically-indicated TVR occurred in 9.4% of BES treated patients versus 11.1% of SES treated patients (HR 0.84 CI 0.62-1.13; p=0.25). Rates of definite stent thrombosis were 2.2% for BES and 2.9% for SES (HR 0.78 CI 0.43-1.43; p=0.43), with the event rate increase of 0.2% from one to three years for BES and 0.9% for SES. For patients presenting with ST-elevation myocardial infarction BES was superior to SES in reducing MACE. Conclusions: The findings of the three year follow-up support the claim that the biodegradable polymer biolimus-eluting stent has equivalent safety and efficacy to permanent polymer sirolimus-eluting stent in an all-comers patient population. Its performance is superior in some subpopulations such as in ST-elevation MI patients and event rates for BES are overall lower than for SES with a trend toward increasing divergence of outcomes over three years. - See more at: http://www.pcronline.com/eurointervention/42nd_issue/125/#sthash.E5HhMQ4a.dpuf

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives This study sought to investigate safety and efficacy of biolimus-eluting stents (BES) with biodegradable polymer as compared with sirolimus-eluting stents (SES) with durable polymer through 2 years of follow-up. Background BES with a biodegradable polymer provide similar efficacy and safety as SES with a durable polymer at 9 months. Clinical outcomes beyond the period of biodegradation of the polymer used for drug release and after discontinuation of dual antiplatelet therapy are of particular interest. Methods A total of 1,707 patients were randomized to unrestricted use of BES (n = 857) or SES (n = 850) in an all-comers patient population. Results At 2 years, BES remained noninferior compared with SES for the primary endpoint, which was a composite of cardiac death, myocardial infarction, or clinically indicated target vessel revascularization (BES 12.8% vs. SES 15.2%, hazard ratio [HR]: 0.84, 95% confidence interval [CI]: 0.65 to 1.08, pnoninferiority < 0.0001, psuperiority = 0.18). Rates of cardiac death (3.2% vs. 3.9%, HR: 0.81, 95% CI: 0.49 to 1.35, p = 0.42), myocardial infarction (6.3% vs. 5.6%, HR: 1.12, 95% CI: 0.76 to 1.65, p = 0.56), and clinically indicated target vessel revascularization (7.5% vs. 8.6%, HR: 0.86, 95% CI: 0.62 to 1.20, p = 0.38) were similar for BES and SES. The rate of definite stent thrombosis through 2 years was 2.2% for BES and 2.5% for SES (p = 0.73). For the period between 1 and 2 years, event rates for definite stent thrombosis were 0.2% for BES and 0.5% for SES (p = 0.42). After discontinuation of dual antiplatelet therapy, no very late definite stent thrombosis occurred in the BES group. Conclusions At 2 years of follow-up, the unrestricted use of BES with a biodegradable polymer maintained a similar safety and efficacy profile as SES with a durable polymer. (Limus Eluted From a Durable Versus Erodable Stent Coating [LEADERS]; NCT00389220)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to compare the angiographic changes in coronary geometry of the bioresorbable vascular scaffolds (BVS) and metallic platform stent (MPS) between baseline and follow-up.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study sought to assess the impact of the SYNTAX (Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery) score (SXscore) on clinical outcomes in patients undergoing percutaneous coronary intervention.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to assess the impact of body mass index (BMI) on clinical outcome of patients treated by percutaneous coronary intervention (PCI) using drug-eluting stents. Patients were stratified according to BMI as normal (<25 kg/m(2)), overweight (25 to 30 kg/m(2)), or obese (>30 kg/m(2)). At 5-year follow-up all-cause death, myocardial infarction, clinically justified target vessel revascularization (TVR), and definite stent thrombosis were assessed. A complete dataset was available in 7,427 patients, of which 45%, 22%, and 33% were classified according to BMI as overweight, obese, and normal, respectively. Mean age of patients was significantly older in those with a normal BMI (p <0.05). Incidence of diabetes mellitus, hypertension, and dyslipidemia increased as BMI increased (p <0.05). Significantly higher rates of TVR (15.3% vs 12.8%, p = 0.02) and early stent thrombosis (1.5% vs 0.9%, p = 0.04) were observed in the obese compared to the normal BMI group. No significant difference among the 3 BMI groups was observed for the composite of death/myocardial infarction/TVR or for definite stent thrombosis at 5 years, whereas the normal BMI group was at higher risk for all-cause death at 5 years (obese vs normal BMI, hazard ratio 0.74, confidence interval 0.53 to 0.99, p = 0.05; overweight vs normal BMI, hazard ratio 0.73, confidence interval 0.59 to 0.94, p = 0.01) in the multivariate Cox proportional hazard model. Age resulted in a linearly dependent covariate with BMI in the all-cause 5-year mortality multivariate model (p = 0.001). In conclusion, the "obesity paradox" observed in 5-year all-cause mortality could be explained by the higher rate of elderly patients in the normal BMI group and the existence of colinearity between BMI and age. However, obese patients had a higher rate of TVR and early stent thrombosis and a higher rate of other risk factors such as diabetes mellitus, hypertension, and hypercholesterolemia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study assessed the ability of the SYNTAX score (SXscore) to stratify risk in patients treated with percutaneous coronary intervention (PCI) using zotarolimus-eluting or everolimus-eluting stents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the safety, device performance, and clinical outcome up to 2 years for patients undergoing transcatheter aortic valve implantation (TAVI).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To report refractive, topographic, aberrometric, and tomographic outcomes 24 months after corneal cross-linking (CXL) in patients up to 18 years of age with progressive keratoconus.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Direct immunofluorescence assays (DFA) are a rapid and inexpensive method for the detection of respiratory viruses and may therefore be used for surveillance. Few epidemiological studies have been published based solely on DFA and none included respiratory picornaviruses and human metapneumovirus (hMPV). We wished to evaluate the use of DFA for epidemiological studies with a long-term observation of respiratory viruses that includes both respiratory picornaviruses and hMPV. Methods Since 1998 all children hospitalized with respiratory illness at the University Hospital Bern have been screened with DFA for common respiratory viruses including adenovirus, respiratory syncytial virus (RSV), influenza A and B, and parainfluenza virus 1-3. In 2006 assays for respiratory picornaviruses and hMPV were added. Here we describe the epidemiological pattern for these respiratory viruses detected by DFA in 10'629 nasopharyngeal aspirates collected from 8'285 patients during a 12-year period (1998-2010). Results Addition of assays for respiratory picornaviruses and hMPV raised the proportion of positive DFA results from 35% to 58% (p < 0.0001). Respiratory picornaviruses were the most common viruses detected among patients ≥1 year old. The seasonal patterns and age distribution for the studied viruses agreed well with those reported in the literature. In 2010, an hMPV epidemic of unexpected size was observed. Conclusions DFA is a valid, rapid, flexible and inexpensive method. The addition of assays for respiratory picornaviruses and hMPV broadens its range of viral detection. DFA is, even in the "PCR era", a particularly adapted method for the long term surveillance of respiratory viruses in a pediatric population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This randomised, controlled multicentre trial aimed at comparing two versions of a variable-thread dental implant design to a standard tapered dental implant design in cases of immediate functional loading for 36 months after loading.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study investigated the efficacy and safety of a balloon expandable, sirolimus-eluting stent (SES) in patients with symptomatic infrapopliteal arterial disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study sought to investigate in vivo the vascular response at the proximal and distal edges of the second-generation ABSORB everolimus-eluting bioresorbable vascular scaffold (BVS).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study sought to compare all-cause mortality in patients at intermediate surgical risk undergoing transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (SAVR).