21 resultados para Liquid chromatography-diode array detection
Resumo:
BACKGROUND: Little is known about the ocular penetration of echinocandin antifungals. We studied the ocular distribution of systemically administered caspofungin in a rabbit uveitis model. METHODS: Caspofungin (1 mg/kg per day) was given intravenously to rabbits as a single dose or as repeated daily doses on 7 days starting 24 h after induction of unilateral uveitis by intravitreal endotoxin injection. Caspofungin concentrations were determined by high-performance liquid chromatography in the cornea, aqueous humor, vitreous humor, and serum 4, 8, 16, and 24 h after administration of a single dose and 24 h after the last of seven doses. RESULTS: The mean caspofungin concentration in the aqueous of the inflamed eye 4 and 8 h after single-dose administration was 1.30 +/- 0.39 mug/ml and 1.12 +/- 0.34 mug/ml, respectively. Drug concentrations decreased to 0.24 +/- 0.09 mug/ml at 16 h and 0.26 +/- 0.14 mug/ml at 24 h. In the vitreous of inflamed eyes drug levels were undetectable at all time points. No drug was found in the aqueous of inflamed eyes 24 h after the last of seven repeated doses, and the vitreous only contained trace amounts. In the corneas of inflamed eyes concentrations reached 1.64 +/- 0.48 mug/g at 4 h, peaked at 2.16 +/- 1.14 mug/g at 8 h, and declined to 1.87 +/- 0.52 mug/g and 1.49 +/- 0.48 mug/g at 16 and 24 h, respectively. After repeated dosing, corneal concentrations of caspofungin were 0.8 and 1.0 mug/g and below the limit of detection in two of four animals. In non-inflamed eyes no drug was detectable in the aqueous and vitreous humor, and the corneas at any time point. CONCLUSIONS: In our model, caspofungin reached therapeutically relevant levels in the aqueous and cornea but not in the vitreous humor of inflamed eyes. Intraocular drug deposition was critically dependent on a disrupted blood-eye barrier. These findings suggest a limited role for caspofungin in the treatment of fungal endophthalmitis.
Resumo:
BACKGROUND: Chemotherapies of solid tumors commonly include 5-fluorouracil (5-FU). With standard doses of 5-FU, substantial inter-patient variability has been observed in exposure levels and treatment response. Recently, improved outcomes in colorectal cancer patients due to pharmacokinetically guided 5-FU dosing were reported. We aimed at establishing a rapid and sensitive method for monitoring 5-FU plasma levels in cancer patients in our routine clinical practice. METHODS: Performance of the Saladax My5-FU™ immunoassay was evaluated on the Roche Cobas® Integra 800 analyzer. Subsequently, 5-FU concentrations of 247 clinical plasma samples obtained with this assay were compared to the results obtained by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and other commonly used clinical analyzers (Olympus AU400, Roche Cobas c6000, and Thermo Fisher CDx90). RESULTS: The My-FU assay was successfully validated on the Cobas Integra 800 analyzer in terms of linearity, precision, accuracy, recovery, interference, sample carryover, and dilution integrity. Method comparison between the Cobas Integra 800 and LC-MS/MS revealed a proportional bias of 7% towards higher values measured with the My5-FU assay. However, when the Cobas Integra 800 was compared to three other clinical analyzers in addition to LC-MS/MS including 50 samples representing the typical clinical range of 5-FU plasma concentrations, only a small proportional bias (≤1.6%) and a constant bias below the limit of detection was observed. CONCLUSIONS: The My5-FU assay demonstrated robust and highly comparable performance on different analyzers. Therefore, the assay is suitable for monitoring 5-FU plasma levels in routine clinical practice and may contribute to improved efficacy and safety of commonly used 5-FU-based chemotherapies.
Resumo:
Lung cancer remains the most common cause of cancer deaths worldwide, yet there is currently a lack of diagnostic noninvasive biomarkers that could guide treatment decisions. Small molecules (<1,500 Da) were measured in urine collected from 469 patients with lung cancer and 536 population controls using unbiased liquid chromatography/mass spectrometry. Clinical putative diagnostic and prognostic biomarkers were validated by quantitation and normalized to creatinine levels at two different time points and further confirmed in an independent sample set, which comprises 80 cases and 78 population controls, with similar demographic and clinical characteristics when compared with the training set. Creatine riboside (IUPAC name: 2-{2-[(2R,3R,4S,5R)-3,4-dihydroxy-5-(hydroxymethyl)-oxolan-2-yl]-1-methylcarbamimidamido}acetic acid), a novel molecule identified in this study, and N-acetylneuraminic acid (NANA) were each significantly (P < 0.00001) elevated in non-small cell lung cancer and associated with worse prognosis [HR = 1.81 (P = 0.0002), and 1.54 (P = 0.025), respectively]. Creatine riboside was the strongest classifier of lung cancer status in all and stage I-II cases, important for early detection, and also associated with worse prognosis in stage I-II lung cancer (HR = 1.71, P = 0.048). All measurements were highly reproducible with intraclass correlation coefficients ranging from 0.82 to 0.99. Both metabolites were significantly (P < 0.03) enriched in tumor tissue compared with adjacent nontumor tissue (N = 48), thus revealing their direct association with tumor metabolism. Creatine riboside and NANA may be robust urinary clinical metabolomic markers that are elevated in tumor tissue and associated with early lung cancer diagnosis and worse prognosis.
Resumo:
PURPOSE Contamination with bacteria and/or fungi is a serious complication in organ-cultured corneas. Hence, antibiotic and antifungal agents are added to the culture medium. The concentration of different antimicrobial and antifungal additives to the media over time has so far not been investigated in detail and is the aim of this study. METHODS Nine human fresh corneoscleral discs were stored in corneal culture medium consisting of 2% fetal bovine serum and minimal essential medium. In addition, the culture medium contained 1200 μg/mL penicillin G, 25 μg/mL amphotericin B, 120 μg/mL streptomycin, and 100 μg/mL voriconazole. The concentration of amphotericin B used was 10 times higher than in clinical routine to facilitate its detection. The cultures were kept at 37°C for 28 days. At days 0, 7, 14, 21, and 28, samples of the culture medium were harvested for analysis of antimicrobial concentrations by liquid chromatography and electrospray ionization tandem mass spectrometry. RESULTS During corneal storage, the concentration of all antibiotics and antifungal agents declined significantly. By day 28, penicillin G was reduced to 14% of the original concentration. Amphotericin B and streptomycin retained approximately 60% of the original concentration to the end of the experiment and voriconazole maintained stable concentrations after an initial decline to approximately 80% at 7 days. CONCLUSIONS Throughout the entire storage period, the concentrations of penicillin G, streptomycin, and voriconazole exceeded the minimum inhibitory concentrations of all common contaminants, obviating the need for a change of the medium for antimicrobial reasons. Based on the minimum inhibitory concentrations and our findings, the initial concentration of amphotericin B should be raised to 5 μg/mL.
Resumo:
The concentration of 11-nor-9-carboxy-Δ(9)-tetrahydrocannabinol (THCCOOH) in whole blood is used as a parameter for assessing the consumption behavior of cannabis consumers. The blood level of THCCOOH-glucuronide might provide additional information about the frequency of cannabis use. To verify this assumption, a column-switching liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the rapid and direct quantification of free and glucuronidated THCCOOH in human whole blood was newly developed. The method comprised protein precipitation, followed by injection of the processed sample onto a trapping column and subsequent gradient elution to an analytical column for separation and detection. The total LC run time was 4.5 min. Detection of the analytes was accomplished by electrospray ionization in positive ion mode and selected reaction monitoring using a triple-stage quadrupole mass spectrometer. The method was fully validated by evaluating the following parameters: linearity, lower limit of quantification, accuracy and imprecision, selectivity, extraction efficiency, matrix effect, carry-over, dilution integrity, analyte stability, and re-injection reproducibility. All acceptance criteria were analyzed and the predefined criteria met. Linearity ranged from 5.0 to 500 μg/L for both analytes. The method was successfully applied to whole blood samples from a large collective of cannabis consumers, demonstrating its applicability in the forensic field.
Resumo:
Proximity-dependent trans-biotinylation by the Escherichia coli biotin ligase BirA mutant R118G (BirA*) allows stringent streptavidin affinity purification of proximal proteins. This so-called BioID method provides an alternative to the widely used co-immunoprecipitation (co-IP) to identify protein-protein interactions. Here, we used BioID, on its own and combined with co-IP, to identify proteins involved in nonsense-mediated mRNA decay (NMD), a post-transcriptional mRNA turnover pathway that targets mRNAs that fail to terminate translation properly. In particular, we expressed BirA* fused to the well characterized NMD factors UPF1, UPF2 and SMG5 and detected by liquid chromatography-coupled tandem mass spectrometry (LC-MS/MS) the streptavidin-purified biotinylated proteins. While the identified already known interactors confirmed the usefulness of BioID, we also found new potentially important interactors that have escaped previous detection by co-IP, presumably because they associate only weakly and/or very transiently with the NMD machinery. Our results suggest that SMG5 only transiently contacts the UPF1-UPF2-UPF3 complex and that it provides a physical link to the decapping complex. In addition, BioID revealed among others CRKL and EIF4A2 as putative novel transient interactors with NMD factors, but whether or not they have a function in NMD remains to be elucidated.