152 resultados para bio-implants


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Survival rates in implant dentistry today are high, although late failures do occur for many reasons, including peri-implant infections. The primary objective of this study is to investigate microbiota around single turned implants after 16 to 22 years. Secondary objectives are to compare teeth and implants and to correlate microbiologic, radiographic, and clinical parameters. METHODS A total of 46 patients with single implants were invited for a clinical examination. Clinical data were collected from implants and contralateral natural teeth. Radiographic bone level was measured around implants. Microbiologic samples were taken from implants, contralateral teeth, and the deepest pocket per quadrant. Samples were analyzed with DNA-DNA hybridization including 40 species. Statistical analysis was performed using Wilcoxon signed-rank tests, McNemar tests, and Spearman correlation coefficients with a 0.05 significance level. RESULTS Mean follow-up was 18.5 years (range 16 to 22 years). Tannerella forsythia (1.5 × 10(5)) and Veillonella parvula (1.02 × 10(5)) showed the highest concentrations around implants and teeth, respectively. Porphyromonas gingivalis, Prevotella intermedia, and T. forsythia were significantly more present around implants than teeth. Mean counts were significantly higher around implants than teeth for Parvimonas micra, P. gingivalis, P. intermedia, T. forsythia, and Treponema denticola. Total DNA count was correlated to interproximal bleeding index (r = 0.409) and interproximal probing depth (r = 0.307). No correlations were present with plaque index or radiographic bone level. CONCLUSIONS In the present study, bacterial counts around single implants in periodontally healthy patients are rather low. Although pathogenic bacteria are present, some in higher numbers around implants than teeth (five of 40), the majority of implants present with healthy peri-implant tissues without progressive bone loss.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE The purpose of this study was to document the long-term outcome of Brånemark implants installed in augmented maxillary bone and to identify parameters that are associated with peri-implant bone level. MATERIAL AND METHODS Patients of a periodontal practice who had been referred to a maxillofacial surgeon for iliac crest bone grafting in the atrophic maxilla were retrospectively recruited. Five months following grafting, they received 7-8 turned Brånemark implants. Following submerged healing of another 5 months, implants were uncovered and restorative procedures for fixed rehabilitation were initiated 2-3 months thereafter. The primary outcome variable was bone level defined as the distance from the implant-abutment interface to the first visible bone-to-implant contact. Secondary outcome variables included plaque index, bleeding index, probing depth, and levels of 40 species in subgingival plaque samples as identified by means of checkerboard DNA-DNA hybridization. RESULTS Nine out of 16 patients (eight females, one male; mean age 59) with 71 implants agreed to come in for evaluation after on average 9 years (SD 4; range 3-13) of function. One implant was deemed mobile at the time of inspection. Clinical conditions were acceptable with 11% of the implants showing pockets ≥ 5 mm. Periodontopathogens were encountered frequently and in high numbers. Clinical parameters and bacterial levels were highly patient dependent. The mean bone level was 2.30 mm (SD 1.53; range 0.00-6.95), with 23% of the implants demonstrating advanced resorption (bone level > 3 mm). Regression analysis showed a significant association of the patient (p < .001) and plaque index (p = .007) with bone level. CONCLUSIONS The long-term outcome of Brånemark implants installed in iliac crest-augmented maxillary bone is acceptable; however, advanced peri-implant bone loss is rather common and indicative of graft resorption. This phenomenon is patient dependent and seems also associated with oral hygiene.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study reports on the surgical and prosthodontic rehabilitation of 46 patients, 31 male and 15 female, after resection of oral tumors. The treatment was carried out from 2004 to 2007 at the Department of Prosthodontics, University of Bern, with a follow-up time of 3 to 6 years. The average age at diagnosis was 54 years. 76% of all tumors were squamous cell carcinoma, followed by adenocarcinoma. Resection of the tumors including soft and/or hard tissues was performed in all patients. 80% of them additionally underwent radiotherapy and 40% chemotherapy. A full block resection of the mandible was perfomed in 23 patients, and in 10 patients, the tumor resection resulted in an oronasal communication. 29 patients underwent grafting procedures, mostly consisting of a free fibula flap transplant. To enhance the prosthetic treatment outcome and improve the prosthesis stability, a total of 114 implants were placed. However, 14 implants were not loaded because they failed during the healing period or the patient could not complete the final treatment with the prostheses. The survival rate of the implants reached 84.2% after 4 to 5 years. Many patients were only partially dentate before the tumors were detected, and further teeth had to be extracted in the course of the tumor therapy. Altogether, 31 jaws became or remained edentulous. Implants provide stability and may facilitate the adaptation to the denture, but their survival rate was compromised. Mostly, patients were fitted with removable prostheses with obturators in the maxilla and implant-supported complete dentures with bars in the mandible. Although sequelae of tumor resection are similar in many patients, the individual intermaxillary relations, facial morphology and functional capacity vary significantly. Thus, individual management is required for prosthetic rehabilitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES The aim was to study the impact of the defect size of endodontically treated incisors compared to dental implants as abutments on the survival of zirconia two-unit anterior cantilever-fixed partial dentures (2U-FPDs) during 10-year simulation. MATERIALS AND METHODS Human maxillary central incisors were endodontically treated and divided into three groups (n = 24): I, access cavities rebuilt with composite core; II, teeth decoronated and restored with composite; and III as II supported by fiber posts. In group IV, implants with individual zirconia abutments were used. Specimens were restored with zirconia 2U-FPDs and exposed to two sequences of thermal cycling and mechanical loading. Statistics: Kaplan-Meier; log-rank tests. RESULTS During TCML in group I two tooth fractures and two debondings with chipping were found. Solely chippings occurred in groups II (2×), IV (2×), and III (1×). No significant different survival was found for the different abutments (p = 0.085) or FPDs (p = 0.526). Load capability differed significantly between groups I (176 N) and III (670 N), and III and IV (324 N) (p < 0.024). CONCLUSION Within the limitations of an in vitro study, it can be concluded that zirconia-framework 2U-FPDs on decoronated teeth with/without post showed comparable in vitro reliability as restorations on implants. The results indicated that restorations on teeth with only access cavity perform worse in survival and linear loading. CLINICAL RELEVANCE Even severe defects do not justify per se a replacement of this particular tooth by a dental implant from load capability point of view.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bone-anchored hearing implants (BAHI) are routinely used to alleviate the effects of the acoustic head shadow in single-sided sensorineural deafness (SSD). In this study, the influence of the directional microphone setting and the maximum power output of the BAHI sound processor on speech understanding in noise in a laboratory setting were investigated. Eight adult BAHI users with SSD participated in this pilot study. Speech understanding in noise was measured using a new Slovak speech-in-noise test in two different spatial settings, either with noise coming from the front and noise from the side of the BAHI (S90N0) or vice versa (S0N90). In both spatial settings, speech understanding was measured without a BAHI, with a Baha BP100 in omnidirectional mode, with a BP100 in directional mode, with a BP110 power in omnidirectional and with a BP110 power in directional mode. In spatial setting S90N0, speech understanding in noise with either sound processor and in either directional mode was improved by 2.2-2.8 dB (p = 0.004-0.016). In spatial setting S0N90, speech understanding in noise was reduced by either BAHI, but was significantly better by 1.0-1.8 dB, if the directional microphone system was activated (p = 0.046), when compared to the omnidirectional setting. With the limited number of subjects in this study, no statistically significant differences were found between the two sound processors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To compare speech understanding of the BAHA BP110 and BAHA Intenso sound processors. STUDY DESIGN Prospective experimental study. SETTING Tertiary referral center. PATIENTS Twenty experienced user of osseointegrated auditory implants with conductive or mixed hearing loss. INTERVENTIONS In a first session, half of the participants were fitted with an Intenso, the other half with a BP110. After 1 month of use, aided speech understanding in quiet and in noise was measured, and the other test processor was fitted. One month later, speech understanding with the second sound processor was assessed. MAIN OUTCOME MEASURES Speech understanding in quiet and in noise, with noise arriving either from the front, the rear, or the side of the user with the osseointegrated bone conductor. RESULTS Significant improvements were found for both processors for speech understanding in quiet (+9.6 to +34.8 percent points; p = 0.02 to 0.001) and in noise (+6.2 to +13.8 dB, p < 0.001). No significant differences were found between the 2 devices for speech in quiet. For noise from the rear, subjects were able to understand speech at signal-to-noise ratios which were lower (less favorable) by -5.1 dB (p < 0.001) when compared with the Intenso. CONCLUSION Speech understanding is substantially improved by both devices, with no significant differences between the sound processors in quiet. In noise, speech understanding is significantly better with the BP110 when compared to the Intenso for noise from the rear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Intraoperatively fabricated polymethylmethacrylate (PMMA) implants based on computer-designed moulds were used to improve cosmetic results after hard tissue replacement. To assess the implant's cosmetic and functional results we performed both subjective and objective assessments. METHODS This retrospective analysis was performed using a cohort of 28 patients who received PMMA implants between February 2009 and March 2012. The cosmetic and functional results were assessed using a patient questionnaire. Furthermore an objective volumetric subtraction score (0-100) was applied and implant thickness, as well as gaps and tiers, were measured. RESULTS Patients mainly judged their cosmetic result as "good". Two of the 28 patients found their cosmetic result unfavourable. The functional result and stability was mainly judged to be good. Measurements of implant thickness showed a very high correlation with the thickness of the contralateral bone. Volumetric subtraction led to a median quality of 80 on a scale from 0 to 100. Median gaps around the margins of the implant were 1.5 mm parietally, 1.7 mm frontally and 3.5 mm fronto-orbitally, and median tiers were 1.2 mm, 0 mm and 0 mm respectively. The overall rate of surgical revisions was 10.7 % (three patients). Two patients suffered from wound healing disturbances (7.1 %). The overall complication rate was comparable to other reports in the literature. CONCLUSIONS Implantation of intraoperatively fabricated patient-specific moulded implants is a cost-effective and safe technique leading to good clinical results with a low complication rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bone Anchored Hearing Implants (BAHI) are routinely used in patients with conductive or mixed hearing loss, e.g. if conventional air conduction hearing aids cannot be used. New sound processors and new fitting software now allow the adjustment of parameters such as loudness compression ratios or maximum power output separately. Today it is unclear, how the choice of these parameters influences aided speech understanding in BAHI users. In this prospective experimental study, the effect of varying the compression ratio and lowering the maximum power output in a BAHI were investigated. Twelve experienced adult subjects with a mixed hearing loss participated in this study. Four different compression ratios (1.0; 1.3; 1.6; 2.0) were tested along with two different maximum power output settings, resulting in a total of eight different programs. Each participant tested each program during two weeks. A blinded Latin square design was used to minimize bias. For each of the eight programs, speech understanding in quiet and in noise was assessed. For speech in quiet, the Freiburg number test and the Freiburg monosyllabic word test at 50, 65, and 80 dB SPL were used. For speech in noise, the Oldenburg sentence test was administered. Speech understanding in quiet and in noise was improved significantly in the aided condition in any program, when compared to the unaided condition. However, no significant differences were found between any of the eight programs. In contrast, on a subjective level there was a significant preference for medium compression ratios of 1.3 to 1.6 and higher maximum power output.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using variothermal polymer micro-injection molding, disposable arrays of eight polymer micro-cantilevers each 500 μm long, 100 μm wide and 25 μm thick were fabricated. The present study took advantage of an easy flow grade polypropylene. After gold coating for optical read-out and asymmetrical sensitization, the arrays were introduced into the Cantisens(®) Research system to perform mechanical and functional testing. We demonstrate that polypropylene cantilevers can be used as biosensors for medical purposes in the same manner as the established silicon ones to detect single-stranded DNA sequences and metal ions in real-time. A differential signal of 7 nm was detected for the hybridization of 1 μM complementary DNA sequences. For 100 nM copper ions the differential signal was found to be (36 ± 5) nm. Nano-mechanical sensing of medically relevant, nanometer-size species is essential for fast and efficient diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alternative fuels are increasingly combusted in diesel- and gasoline engines and the contribution of such exhausts to the overall air pollution is on the rise. Recent findings on the possible adverse effects of biodiesel exhaust are contradictive, at least partly resulting from the various fuel qualities, engine types and different operation conditions that were tested. However, most of the studies are biased by undesired interactions between the exhaust samples and biological culture media. We here report how complete, freshly produced exhausts from fossil diesel (B0), from a blend of 20% rapeseed-methyl ester (RME) and 80% fossil diesel (B20) and from pure rapeseed methyl ester (B100) affect a complex 3D cellular model of the human airway epithelium in vitro by exposing the cells at the air–liquid interface. The induction of pro-apoptotic and necrotic cell death, cellular morphology, oxidative stress, and pro-inflammatory responses were assessed. Compared to B0 exhaust, B20 exhaust decreased oxidative stress and pro-inflammatory responses, whereas B100 exhaust, depending on exposure duration, decreased oxidative stress but increased pro-inflammatory responses. The effects are only very weak and given the compared to fossil diesel higher ecological sustainability of biodiesel, it appears that – at least RME – can be considered a valuable alternative to pure fossil diesel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-performance thermoplastics including polyetheretherketone (PEEK) are key biomaterials for load-bearing implants. Plasma treatment of implants surfaces has been shown to chemically activate its surface, which is a prerequisite to achieve proper cell attachment. Oxygen plasma treatment of PEEK films results in very reproducible surface nanostructures and has been reported in the literature. Our goal is to apply the plasma treatment to another promising polymer, polyetherketoneketone (PEKK), and compare its characteristics to the ones of PEEK. Oxygen plasma treatments of plasma powers between 25 and 150 W were applied on 60 μm-thick PEKK and 100 μm-thick PEEK films. Analysis of the nanostructures by atomic force microscopy showed that the roughness increased and island density decreased with plasma power for both PEKK and PEEK films correlating with contact angle values without affecting bulk properties of the used films. Thermal analysis of the plasma-treated films shows that the plasma treatment does not change the bulk properties of the PEKK and PEEK films.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Zirconia (ZrO2 ) has received interest as a dental material; however, little information is available on the impact of surface modifications on the osseointegration of zirconia implants. PURPOSE: The aim of the present study was to determine the effect of acid or alkaline etching of sandblasted ZrO2 implants on bone apposition in vivo. METHODS: Cylindrical ZrO2 implants with two circumferential grooves were placed in the maxilla of 12 miniature pigs. Biopsies were harvested after 1, 2, 4, and 8 weeks of healing. Undecalcified toluidine blue-stained ground sections were produced. The bone-to-implant contact, the bone area, and the presence of multinucleated giant cells were determined by histomorphometry. An uncorrected explorative statistical analysis was performed. RESULTS: Acid etching but not alkaline etching of sandblasted ZrO2 implants caused more bone-to-implant contact than sandblasted ZrO2 implants. The bone area was unaffected by the surface modifications. Acid and alkaline etching both increased the formation of multinucleated giant cells at the implant surface. CONCLUSIONS: This study provides a scientific basis to further investigate the impact of acid etching of sandblasted ZrO2 implants on osseointegration and the role of multinucleated giant cells in this process.