Are implants more reliable than severely compromised endodontically treated teeth as abutments for zirconia-based FPDs? : In vitro results of long-term preclinical load simulation


Autoria(s): Naumann, Michael; Hohmann, C.; Happe, Arndt; Beuer, Florian; Frankenberger, Roland; Seemann, Rainer; Rosentritt, Martin
Data(s)

01/09/2013

Resumo

OBJECTIVES The aim was to study the impact of the defect size of endodontically treated incisors compared to dental implants as abutments on the survival of zirconia two-unit anterior cantilever-fixed partial dentures (2U-FPDs) during 10-year simulation. MATERIALS AND METHODS Human maxillary central incisors were endodontically treated and divided into three groups (n = 24): I, access cavities rebuilt with composite core; II, teeth decoronated and restored with composite; and III as II supported by fiber posts. In group IV, implants with individual zirconia abutments were used. Specimens were restored with zirconia 2U-FPDs and exposed to two sequences of thermal cycling and mechanical loading. Statistics: Kaplan-Meier; log-rank tests. RESULTS During TCML in group I two tooth fractures and two debondings with chipping were found. Solely chippings occurred in groups II (2×), IV (2×), and III (1×). No significant different survival was found for the different abutments (p = 0.085) or FPDs (p = 0.526). Load capability differed significantly between groups I (176 N) and III (670 N), and III and IV (324 N) (p < 0.024). CONCLUSION Within the limitations of an in vitro study, it can be concluded that zirconia-framework 2U-FPDs on decoronated teeth with/without post showed comparable in vitro reliability as restorations on implants. The results indicated that restorations on teeth with only access cavity perform worse in survival and linear loading. CLINICAL RELEVANCE Even severe defects do not justify per se a replacement of this particular tooth by a dental implant from load capability point of view.

Formato

application/pdf

Identificador

http://boris.unibe.ch/40838/1/ClinOralInvest.pdf

Naumann, Michael; Hohmann, C.; Happe, Arndt; Beuer, Florian; Frankenberger, Roland; Seemann, Rainer; Rosentritt, Martin (2013). Are implants more reliable than severely compromised endodontically treated teeth as abutments for zirconia-based FPDs? : In vitro results of long-term preclinical load simulation. Clinical oral investigations, 17(7), pp. 1685-1692. Springer 10.1007/s00784-012-0866-2 <http://dx.doi.org/10.1007/s00784-012-0866-2>

doi:10.7892/boris.40838

info:doi:10.1007/s00784-012-0866-2

info:pmid:23103959

urn:issn:1432-6981

Idioma(s)

eng

Publicador

Springer

Relação

http://boris.unibe.ch/40838/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Naumann, Michael; Hohmann, C.; Happe, Arndt; Beuer, Florian; Frankenberger, Roland; Seemann, Rainer; Rosentritt, Martin (2013). Are implants more reliable than severely compromised endodontically treated teeth as abutments for zirconia-based FPDs? : In vitro results of long-term preclinical load simulation. Clinical oral investigations, 17(7), pp. 1685-1692. Springer 10.1007/s00784-012-0866-2 <http://dx.doi.org/10.1007/s00784-012-0866-2>

Palavras-Chave #610 Medicine & health
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed