13 resultados para dilution
em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha
Resumo:
An accurate and sensitive species-specific GC-ICP-IDMS (gas chromatography inductively coupled plasma isotope dilution mass spectrometry) method for the determination of trimethyllead and a multi-species-specific GC-ICP-IDMS method for the simultaneous determination of trimethyllead, methylmercury, and butyltins in biological and environmental samples were developed. They allow the determination of corresponding elemental species down to the low ng g-1 range. The developed synthesis scheme for the formation of isotopically labeled Me3206Pb+ can be used for future production of this spike. The novel extraction technique, stir bar sorptive extraction (SBSE), was applied for the first time in connection with species-specific isotope dilution GC-ICP-MS for the determination of trimethyllead, methylmercury and butyltins. The results were compared with liquid-liquid extraction. The developed methods were validated by the analysis of certified reference materials. The liquid-liquid extraction GC-ICP-IDMS method was applied to seafood samples purchased from a supermarket. The methylated lead fraction in these samples, correlated to total lead, varied in a broad range of 0.01-7.6 %. On the contrary, the fraction of methylmercury is much higher, normally in the range of 80-98 %. The highest methylmercury content of up to 12 µg g-1 has been determined in shark samples, an animal which is at the end of the marine food chain, whereas in other seafood samples a MeHg+ content of less than 0.2 µg g-1 was found. Butyltin species could only be determined in samples, where anthropogenic contaminations must be assumed. This explains the observed broad variation of the butylated tin fraction in the range of <0.3-49 % in different seafood samples. Because all isotope-labelled spike compounds, except trimethyllead, are commercially available, the developed multi-species-specific GC-ICP-IDMS method has a high potential in future for routine analysis.
Resumo:
Ein eindimensionales numerisches Modell der maritimenGrenzschicht (MBL) wurde erweitert, um chemische Reaktionenin der Gasphase, von Aerosolpartikeln und Wolkentropfen zu beschreiben. Ein Schwerpunkt war dabei die Betrachtung derReaktionszyklen von Halogenen. Soweit Ergebnisse vonMesskampagnen zur Verfuegung standen, wurden diese zurValidierung des Modells benutzt. Die Ergebnisse von frueheren Boxmodellstudien konntenbestaetigt werden. Diese zeigten die saeurekatalysierteAktivierung von Brom aus Seesalzaerosolen, die Bedeutung vonHalogenradikalen fuer die Zerstoerung von O3, diepotentielle Rolle von BrO bei der Oxidation von DMS und dievon HOBr und HOCl in der Oxidation von S(IV). Es wurde gezeigt, dass die Beruecksichtigung derVertikalprofile von meteorologischen und chemischen Groessenvon grosser Bedeutung ist. Dies spiegelt sich darin wider,dass Maxima des Saeuregehaltes von Seesalzaerosolen und vonreaktiven Halogenen am Oberrand der MBL gefunden wurden.Darueber hinaus wurde die Bedeutung von Sulfataerosolen beidem aktiven Recyceln von weniger aktiven zu photolysierbarenBromspezies gezeigt. Wolken haben grosse Auswirkungen auf die Evolution und denTagesgang der Halogene. Dies ist nicht auf Wolkenschichtenbeschraenkt. Der Tagesgang der meisten Halogene ist aufgrundeiner erhoehten Aufnahme der chemischen Substanzen in die Fluessigphase veraendert. Diese Ergebnisse betonen dieWichtigkeit der genauen Dokumentation der meteorologischenBedingungen bei Messkampagnen (besonders Wolkenbedeckungsgrad und Fluessigwassergehalt), um dieErgebnisse richtig interpretieren und mit Modellresultatenvergleichen zu koennen. Dieses eindimensionale Modell wurde zusammen mit einemBoxmodell der MBL verwendet, um die Auswirkungen vonSchiffemissionen auf die MBL abzuschaetzen, wobei dieVerduennung der Abgasfahne parameterisiert wurde. DieAuswirkungen der Emissionen sind am staerksten, wenn sie insauberen Gebieten stattfinden, die Hoehe der MBL gering istund das Einmischen von Hintergrundluft schwach ist.Chemische Reaktionen auf Hintergrundaerosolen spielen nureine geringe Rolle. In Ozeangebieten mit schwachemSchiffsverkehr sind die Auswirkungen auf die Chemie der MBL beschraenkt. In staerker befahrenen Gebieten ueberlappensich die Abgasfahnen mehrerer Schiffe und sorgen fuerdeutliche Auswirkungen. Diese Abschaetzung wurde mitSimulationen verglichen, bei denen die Emissionen alskontinuierliche Quellen behandelt wurden, wie das inglobalen Chemiemodellen der Fall ist. Wenn die Entwicklungder Abgasfahne beruecksichtigt wird, sind die Auswirkungendeutlich geringer da die Lebenszeit der Abgase in der erstenPhase nach Emission deutlich reduziert ist.
Resumo:
ZusammenfassungSchwerpunkt dieser Arbeit war die Verfahrensentwicklung zur Ultraspurenbestimmung der Platingruppenelemente (PGE) in Umwelt- und geologischen Proben unter Verwendung der massenspektrometrischen Isotopenverdünnungsanalyse mit anschließender Bestimmung an einem Quadrupol ICP-MS (ICP-QMSIVA). Geeignete Separationstechniken in der Probenaufbereitung, um die PGE von der Matrix der untersuchten Proben zu trennen, stellten eine richtige und präzise Bestimmung der Ultraspuren an einem Quadrupol ICP-MS sicher.Das Verfahren konnte anhand von geologischen Referenzmaterialien aus Kanada sichergestellt werden. Gerade die Wiederholungsbestimmungen der verschiedenen Referenzmaterialien unter Verwendung des ICP-QMSIVA Verfahrens sind beispiellos und in dieser Form noch nicht in der Literatur beschrieben. Durch systematische Messungen konnten Richtigkeit und Präzision des Verfahrens bestätigt werden und die Inhomogenität des Referenzmaterials UMT-1 bezüglich Pt bewiesen werden. Das in dieser Arbeit entwickelte Verfahren zur Ultraspurenbestimmung der PGE mit ICP-QMSIVA wurde im Rahmen des Projektes 'Production and certification of a road dust reference material for platinum, palladium and rhodium (PGEs) in automative catalytic converters (PACEPAC)' der Europäischen Union zur Zertifizierung von zwei Referenzmaterialien für Umweltproben eingesetzt. Hierbei wurde bei der Zertifizierung ('intercomparison round') eine sehr gute Übereinstimmung der Ergebnisse mit dem gewichteten Mittelwert der Ergebnisse für Pd und Pt mit den übrigen teilnehmenden Laboratorien festgestellt. Die mit der hier entwickelten Methode erhaltenen Ergebnisse wurden ohne Ausnahme für alle gemessenen Elemente zur Zertifizierung herangezogen. Damit leistete die vorliegende Arbeit einen erheblichen Beitrag zum erfolgreichen Abschluß dieses Projekts. Den Erwartungen hinsichtlich Richtigkeit und Reproduzierbarkeit des entwickelten Verfahrens wurde somit voll entsprochen. Erneut konnte die große Bedeutung der Isotopenverdünnungstechnik für die Zertifizierung von Referenzmaterialien aufgezeigt werden, da mit dieser Technik bei sachgerechtem Einsatz Ergebnisse hoher Richtigkeit erzielt werden. Durch vergleichende Messungen mit der NiS-Dokimasie und NAA, die in einer Kooperation mit dem Kernchemischen Institut der Universität Mainz durchgeführt wurden, und dem hier verwendeten Verfahren, konnten übereinstimmende Daten, hinsichtlich der Abnahme der Konzentrationen von Pd und Pt in Abhängigkeit von der Entfernung zu einer Autobahn, erzielt werden. Diese Arbeit und die Forschungsergebnisse, die mit der anerkannten NAA erzielt wurden, zeigen, daß die PGE durch Katalysatoren von Automobilen überwiegend metallisch emittiert werden. Der anthropogene Eintrag der PGE in die Umwelt kann mit dem ICP-QMSIVA Verfahren weiterhin sehr gut verfolgt werden.
Resumo:
This work describes the synthesis of a new class of rod-coil block copolymers, oligosubstituted shape persistent macrocycles, (coil-ring-coil block copolymers), and their behavior in solution and in the solid state.The coil-ring-coil block copolymers are formed by nanometer sized shape persistent macrocycles based on the phenyl-ethynyl backbone as rigid block and oligomers of polystyrene or polydimethylsiloxane as flexible blocks. The strategy that has been followed is to synthesize the macrocycles with an alcoholic functionality and the polymer carboxylic acids independently, and then bind them together by esterification. The ester bond is stable and relatively easy to form.The synthesis of the shape persistent macrocycles is based on two separate steps. In the first step the building blocks of the macrocycles are connected by Hagiara-Sogonaschira coupling to form an 'half-ring' as precursor, that contains two free acetylenes. In the second step the half-ring is cyclized by forming two sp-sp bonds via a copper-catalyzed Glaser coupling under pseudo-high-dilution conditions. The polystyrene carboxylic acid was prepared directly by siphoning the living anionic polymer chain into a THF solution, saturated with CO2, while the polydimethylsiloxane carboxylic acid was obtained by hydrosilylating an unsaturated benzylester with an Si-H terminated polydimethylsiloxane, and cleavage of the ester. The carbodiimide coupling was found to be the best way to connect macrocycles and polymers in high yield and high purity.The polystyrene-ring-polystyrene block copolymers are, depending on the molecular weight of the polystyrene, lyotropic liquid crystals in cyclohexane. The aggregation behavior of the copolymers in solution was investigated in more detail using several technique. As a result it can be concluded that the polystyrene-ring-polystyrene block copolymers can aggregate into hollow cylinder-like objects with an average length of 700 nm by a combination of shape complementary and demixing of rigid and flexible polymer parts. The resulting structure can be described as supramolecular hollow cylindrical brush.If the lyotropic solution of the polystyrene-ring-polystyrene block copolymers are dried, they remain birefringent indicating that the solid state has an ordered structure. The polydimethylsiloxane-ring-polydimethylsiloxane block copolymers are more or less fluid at room temperature, and are all birefringent (termotropic liquid crystals) as well. This is a prove that the copolymers are ordered in the fluid state. By a careful investigation using electron diffraction and wide-angle X-ray scattering, it has been possible to derive a model for the 3D-order of the copolymers. The data indicate a lamella structure for both type of copolymers. The macrocycles are arranged in a layer of columns. These crystalline layers are separated by amorphous layers which contain the polymers substituents.
Resumo:
Im Rahmen dieser Arbeit ist es gelungen, ein GC/ICP-MSIVA-Verfahren zur zuverlässigen und richtigen Bestimmung von Methylquecksilbergehalten (MeHg+) in aquatischen Systemen zu entwickeln. Unter Verwendung eines hergestellten Me201Hg+-Indikators konnte bei der Überprüfung der weltweit gängigen Probenaufbereitung mittels NaBEt4 zur Überführung von MeHg+ in MeEtHg gezeigt werden, daß während dieser Probenaufbereitung in Gegenwart von Halogeniden eine MeHg+-Speziesumwandlung zu Hg0 stattfinden kann. Es konnte mit Hilfe von Modellösungen erstmalig eindeutig nachgewiesen werden, daß die MeHg+-Speziesumwandlungen ihre Ursache nur im Zusammenwirken von vorliegenden Halogeniden mit dem verwendeten Derivatisierungsreagenz NaBEt4 haben. Ebenso wie in Modellösungen wurden auch MeHg+-Speziesumwandlungen in Realproben bei der Derivatisierung mit NaBEt4 überprüft. Die Proben, die bei der Derivatisierung mit NaBEt4 eine MeHg+-Umwandlung zeigten, wurden auch mit dem weltweit bisher wenig eingesetzten Reagenz NaBPr4 derivatisiert. Hier konnte bei keiner der Untersuchungen eine MeHg+-Umwandlung festgestellt werden. Des weiteren wurden MeHg+-Gehalte in Süßwasserproben unter Verwendung von NaBEt4 und NaBPr4 bestimmt. Die Ergebnisse hinsichtlich beider Derivatisierungsreagenzien stimmten sehr gut überein. Diese Resultate zeigten eindrucksvoll, daß Substanzverluste durch die Speziesumwandlung bei MeHg+-Bestimmungen mit MSIVA keine Rolle spielen, da die Umwandlung erst nach der Isotopenvermischung einsetzte. Mit dem entwickelten GC/ICP-MSIVA-Verfahrens wurde der MeHg+-Gehalt im Referenzmaterial CRM 463 analysiert, der sehr gut mit dem zertifizierten Wert übereinstimmte.
Resumo:
Deutsch:Schwerpunkt dieser Arbeit war die Entwicklung einer Methode zur Spurenbestimmung von Silicium in organischen und anorganischen Matrices unter Verwendung der massenspektrometrischen Isotopenverdünnungsanalyse (MSIVA) an einem hochauflösenden induktiv gekoppelten Plasma-Massenspektrometer (HR-ICP-MS). Zusätzlich zur Elementspurenbestimmung wurde eine GC/HR-ICP-MS Kopplung entwickelt, die zur Analyse linearer und cyclischer Siloxane verwendet wurde.Die hier entwickelte Analysenmethode erlaubt Nachweisgrenzen für Silicium sowohl in organischen als auch in anorganischen Matrices im oberen ng/g-Bereich und ergab für die im Rahmen dieser Arbeit analysierten Proben Reproduzierbarkeiten von < 20%. Durch einfache Verdünnung nach der Probenvorbereitung in Verbindung mit dem sehr empfindlichen Detektionsverfahren sowie der internen Standardisierung mittels MSIVA erlaubt das Verfahren eine präzise Bestimmung von Silicium in jeglicher Matrix. Neben der Schnelligkeit und Einfachheit eignet sich die hier entwickelte Methode besonders für die Routineanalytik. Die gute Reproduzierbarkeit und der Vergleich mit Ergebnissen von zwei Interlaborstudien unterstreicht zusätzlich die Fähigkeit präzise und richtige Ergebnisse zur Zertifizierung an Standardreferenzmaterialien bezüglich des Siliciums im Spurenbereich zu liefern.Neben dem Gesamtgehalt von Silicium konnten medizinisch relevante Siliciumverbindungen analysiert und quantifiziert werden. Hierbei wurden niedermolekulare Polydimethlysiloxane (PDMS) untersucht, die als Nebenprodukte vor allem in Brustimplantaten auftreten. Grundlage für die Bestimmung dieser Siliciumspezies ist die Kopplung eines hochauflösenden ICP-MS an einen Gaschromatographen. Der hohe Ionisierungsgrad des ICP, gerade unter trockenen Plasmabedingungen, und der elementspezifische und sehr empfindliche massenspektrometrische Detektor erlauben in Verbindung mit dem GC die Bestimmung von Siloxanen bis in den pg/g-Bereich. Aus der Bestimmung des Gesamtgehalts an Silicium und der Bestimmung des Gehalts an den untersuchten Siliciumverbindungen können Vergleiche gemacht werden. Die Analyse beider Parameter ist mit Hilfe in dieser Arbeit entwickelten Methode möglich.Zusätzlich zur Siliciumbestimmung wurde der Gehalt an Platin in Humanproben analysiert, da bei der Herstellung der Füllung von Siliconimplantaten Platinkatalysatoren verwendet werden.
Resumo:
In dieser Arbeit wurde erstmalig eine massenspektrometrische Isotopenverdünnungsanalyse (MSIVA) als Quantifizierungsmethode für die Multielementbestimmung in pulverförmigen Proben mittels Laserablations-induktiv gekoppelter Plasma-Massenspektrometrie (LA-ICP-MS) entwickelt. Diese LA-ICP-MSIVA wurde zur Bestimmung von Elementspuren in optisch-reinem Calciumfluorid eingesetzt und anhand der Analyse mehrerer zertifizierter Referenzmaterialien unterschiedlicher Matrixzusammensetzung validiert.Mit den in dieser Arbeit entwickelten direkten LA-ICP-MS-Analysenmethoden dürfte es in der Zukunft möglich sein, Routineanalysen von optisch-reinem Calciumfluorid durchzuführen, wobei sich im Vergleich zu naßchemischen Aufschlußverfahren eindeutige Vorteile ergeben. Neben einer deutlich einfacheren und weniger kontaminationsanfälligen Probenvorbereitung liegen die Nachweisgrenzen (im Bereich von 0.05 ng/g für Zr bis 20 ng/g für Mg) um etwa ein bis drei Größenordnungen niedriger.Die am Beispiel der Multielementbestimmung in Calciumfluorid entwickelte LA-ICP-MSIVA wurde nachfolgend anhand der Analyse von sieben zertifizierten Referenzmaterialien mit organischer und anorganischer Matrix validiert. Hierbei wurde für 28 von insgesamt 32 analysierten Elementkonzentrationen eine hervorragende Übereinstimmung mit den zertifizierten Werten erhalten. Im Mittel weichen die mittels LA-ICP-MSIVA analysierten Gehalte nur um 1.6 % von den zertifizierten Werten ab. Die erzielte Präzision von durchschnittlich 4.9 % relativer Standardabweichung für drei unabhängig analysierte Proben liegt im Bereich der durchschnittlichen zertifizierten Unsicherheit der Referenzmaterialien von 4.4 %.
Resumo:
We have elaborated a multistep strategy to synthesize ABAB-type tetraureas. There are overall nine steps but they involve very simple chemistry. The sequence starts with a 1,3-dialkylation and this is the step in which a difference between distal phenolic units is introduced. The selective ipso-nitration in the next step is based on the difference in reactivity between free phenolic units and alkylated ones. The direct reaction of tetraamino calixarene with tolylisocyanate appears not to be an appropriate method to synthesize 1,3-ditolylurea calixarenes but can be used to get tetraureas of ABBB- and AABB-types in two steps with yields of about 60%. A complete regioselective dimerization was obtained with mono-loop derivatives in which two adjacent urea residues are covalently connected. As predicted/expected the loop prevents the formation of one regioisomer, and only the dimer in which the open-chain residue slips through the loop is formed. To synthesize mono-loop tetraureas 1,2-diBoc protected tetraamino calixarene was acylated with activated di-urethanes under high dilution conditions. Di-loop compounds were synthesized by two different ways. In the reaction of tetraamine and di-urethanes the yield is about 30-40%. The second method is based on the metathesis reaction within a suitable heterodimer. For this strategy, tetraurea derivatives with residues which have terminal double bonds were prepared. The exclusive formation of the heterodimer with tetratosylurea as template is the key point in this strategy. Metathesis followed by hydrogenation give exceptionally good yields (> 80%) of the loop compounds. All the NMR data for di-loop compounds confirm that the loops prevent the interaction of the urea residues which are connected and thus, as expected, the di-loop derivatives do not form homodimers. The heterodimer between di-loop compounds and tetratolylurea (open-chain tetraureas) was the only species observed for a 1:1 mixture in benzene or chloroform. The rational synthesis of bis-[2]catenanes was a consequence of the selective formation of one regioisomer of mono-loop derivatives and the exclusive formation of heterodimers by di-loop derivatives. The formation of interlocking-ring in the synthesis of bis-[2]catenanes is an additional evidence that one open-chain residue slips through the loop in mono- or di-loop derivatives. Exceptionally good yields in the synthesis of bis-[2]catenanes are due to the high preorganization in the dimer which undergoes the metathesis. This preorganization decreases the number of the wrong connections and favors the new connections to be formed. Although the procedure for working up the reaction mixture should be still improved, these results are promising. A C2-symmetrical bis-[2]catenane was successfully resolved by column chromatography using a chiral stationary phase. Thus it should be possible to separate a larger amount to obtain pure enantiomers for further studies.
Resumo:
The research interest of this study is to investigate surface immobilization strategies for proteins and other biomolecules by the surface plasmon field-enhanced fluorescence spectroscopy (SPFS) technique. The recrystallization features of the S-layer proteins and the possibility of combining the S-layer lattice arrays with other functional molecules make this protein a prime candidate for supramolecular architectures. The recrystallization behavior on gold or on the secondary cell wall polymer (SCWP) was recorded by SPR. The optical thicknesses and surface densities for different protein layers were calculated. In DNA hybridization tests performed in order to discriminate different mismatches, recombinant S-layer-streptavidin fusion protein matrices showed their potential for new microarrays. Moreover, SCWPs coated gold chips, covered with a controlled and oriented assembly of S-layer fusion proteins, represent an even more sensitive fluorescence testing platform. Additionally, S-layer fusion proteins as the matrix for LHCII immobilization strongly demonstrate superiority over routine approaches, proving the possibility of utilizing them as a new strategy for biomolecular coupling. In the study of the SPFS hCG immunoassay, the biophysical and immunological characteristics of this glycoprotein hormone were presented first. After the investigation of the effect of the biotin thiol dilution on the coupling efficiently, the interfacial binding model including the appropriate binary SAM structure and the versatile streptavidin-biotin interaction was chosen as the basic supramolecular architecture for the fabrication of a SPFS-based immunoassay. Next, the affinity characteristics between different antibodies and hCG were measured via an equilibrium binding analysis, which is the first example for the titration of such a high affinity interaction by SPFS. The results agree very well with the constants derived from the literature. Finally, a sandwich assay and a competitive assay were selected as templates for SPFS-based hCG detection, and an excellent LOD of 0.15 mIU/ml was attained via the “one step” sandwich method. Such high sensitivity not only fulfills clinical requirements, but is also better than most other biosensors. Fully understanding how LHCII complexes transfer the sunlight energy directionally and efficiently to the reaction center is potentially useful for constructing biomimetic devices as solar cells. After the introduction of the structural and the spectroscopic features of LHCII, different surface immobilization strategies of LHCII were summarized next. Among them the strategy based on the His-tag and the immobilized metal (ion) affinity chromatography (IMAC) technique were of great interest and resulted in different kinds of home-fabricated His-tag chelating chips. Their substantial protein coupling capacity, maintenance of high biological activity and a remarkably repeatable binding ability on the same chip after regeneration was demonstrated. Moreover, different parameters related to the stability of surface coupled reconstituted complexes, including sucrose, detergent, lipid, oligomerization, temperature and circulation rate, were evaluated in order to standardize the most effective immobilization conditions. In addition, partial lipid bilayers obtained from LHCII contained proteo-liposomes fusion on the surface were observed by the QCM technique. Finally, the inter-complex energy transfer between neighboring LHCIIs on a gold protected silver surface by excitation with a blue laser (λ = 473nm) was recorded for the first time, and the factors influencing the energy transfer efficiency were evaluated.
Resumo:
Für die vorliegende Arbeit wurde die chemische Zusammensetzung von natürlichen und anthropogenen Aerosolpartikeln untersucht. Zu diesem Zweck wurde das Aerosolmassenspektrometer (AMS) der Firma Aerodyne, Inc. eingesetzt, womit neben den chemischen Substanzen auch die Massengrößenverteilungen der einzelnen Komponenten der Aerosolpartikel in einem Größenbereich zwischen 20 und 1500 nm quantitativ gemessen werden können. Im Rahmen der HAZE2002-Messkampagne am Meteorologischen Observatorium Hohenpeißenberg wurden die Aerosolpartikel aus natürlichen Quellen untersucht. Diese Partikel bestanden aus Sulfat, Nitrat, Ammonium und organischen Komponenten (Organics). Sulfat, Nitrat und Ammonium wiesen den gleichen Durchmesser auf, was auf eine interne Mischung dieser drei chemischen Substanzen in den Partikeln hinwies. Die Organics hatten einen kleineren Durchmesser, was auf jüngere Partikel hindeutete. Die Analyse der organischen Substanzen in den Aerosolpartikeln zeigte, dass diese zu einem großen Teil aus oxidierten Kohlenwasserstoffen bestanden, die während den Nachmittagsstunden gebildet wurden. Die thermische Abhängigkeit der Bildung von Ammoniumnitrat konnte sowohl gemessen als auch mit Hilfe Konzentrationsberechnungen nach [Seinfeld und Pandis, 1998] nachvollzogen werden. Die gemessene Partikelneubildung konnte auf die ternäre Nukleation aus H2SO4/H2O/NH3 zurückgeführt werden. Aerosolpartikel aus anthropogenen Quellen, wie z.B. der motorischen Verbrennung, wurden während der Messungen in Zusammenarbeit mit dem Ford Forschungszentrum in Aachen (FFA) untersucht. Nukleationspartikel (D 45 nm) konnten bei Experimenten auf dem Rollenprüfstand nur bei einer ausreichend hohen Verdünnung, einem hohen Schwefelgehalt im Kraftstoff und einem hohen Lastzustand nachgewiesen werden. Die Messungen an der Autobahn A4 ergaben eine bimodale Massengrößenverteilung der organischen Partikel, wobei die erste Mode Partikeln aus der motorischen Verbrennungen zugeschrieben werden konnte. Aufgrund der guten Charakterisierung stellt das AMS ein vielseitig einsetzbares Aerosolmessgerät dar, welches in einer hohen Zeitauflösung eine quantitative, größenaufgelöste chemische Analyse der zu messenden Aerosolpartikel bereitstellt.
Resumo:
In the course of this work the effect of metal substitution on the structural and magnetic properties of the double perovskites Sr2MM’O6 (M = Fe, substituted by Cr, Zn and Ga; M’ = Re, substituted by Sb) was explored by means of X-ray diffraction, magnetic measurements, band structure calculations, Mößbauer spectroscopy and conductivity measurements. The focus of this study was the determination of (i) the kind and structural boundary conditions of the magnetic interaction between the M and M’ cations and (ii) the conditions for the principal application of double perovskites as spintronic materials by means of the band model approach. Strong correlations between the electronic, structural and magnetic properties have been found during the study of the double perovskites Sr2Fe1-xMxReO6 (0 < x < 1, M = Zn, Cr). The interplay between van Hove-singularity and Fermi level plays a crucial role for the magnetic properties. Substitution of Fe by Cr in Sr2FeReO6 leads to a non-monotonic behaviour of the saturation magnetization (MS) and an enhancement for substitution levels up to 10 %. The Curie temperatures (TC) monotonically increase from 401 to 616 K. In contrast, Zn substitution leads to a continuous decrease of MS and TC. The diamagnetic dilution of the Fe-sublattice by Zn leads to a transition from an itinerant ferrimagnetic to a localized ferromagnetic material. Thus, Zn substitution inhibits the long-range ferromagnetic interaction within the Fe-sublattice and preserves the long-range ferromagnetic interaction within the Re-sublattice. Superimposed on the electronic effects is the structural influence which can be explained by size effects modelled by the tolerance factor t. In the case of Cr substitution, a tetragonal – cubic transformation for x > 0.4 is observed. For Zn substituted samples the tetragonal distortion linearly increases with increasing Zn content. In order to elucidate the nature of the magnetic interaction between the M and M’ cations, Fe and Re were substituted by the valence invariant main group metals Ga and Sb, respectively. X-ray diffraction reveals Sr2FeRe1-xSbxO6 (0 < x < 0.9) to crystallize without antisite disorder in the tetragonal distorted perovskite structure (space group I4/mmm). The ferrimagnetic behaviour of the parent compound Sr2FeReO6 changes to antiferromagnetic upon Sb substitution as determined by magnetic susceptibility measurements. Samples up to a doping level of 0.3 are ferrimagnetic, while Sb contents higher than 0.6 result in an overall antiferromagnetic behaviour. 57Fe Mößbauer results show a coexistence of ferri- and antiferromagnetic clusters within the same perovskite-type crystal structure in the Sb substitution range 0.3 < x < 0.8, whereas Sr2FeReO6 and Sr2FeRe0.9Sb0.1O6 are “purely” ferrimagnetic and Sr2FeRe0.1Sb0.9O6 contains antiferromagnetically ordered Fe sites only. Consequently, a replacement of the Re atoms by a nonmagnetic main group element such as Sb blocks the double exchange pathways Fe–O–Re(Sb)–O–Fe along the crystallographic axis of the perovskite unit cell and destroys the itinerant magnetism of the parent compound. The structural and magnetic characterization of Sr2Fe1-xGaxReO6 (0 < x < 0.7) exhibit a Ga/Re antisite disorder which is unexpected because the parent compound Sr2FeReO6 shows no Fe/Re antisite disorder. This antisite disorder strongly depends on the Ga content of the sample. Although the X-ray data do not hint at a phase separation, sample inhomogeneities caused by a demixing are observed by a combination of magnetic characterization and Mößbauer spectroscopy. The 57Fe Mößbauer data suggest the formation of two types of clusters, ferrimagnetic Fe- and paramagnetic Ga-based ones. Below 20 % Ga content, Ga statistically dilutes the Fe–O–Re–O–Fe double exchange pathways. Cluster formation begins at x = 0.2, for 0.2 < x < 0.4 the paramagnetic Ga-based clusters do not contain any Fe. Fe containing Ga-based clusters which can be detected by Mößbauer spectroscopy firstly appear for x = 0.4.
Resumo:
Zusammenfassung Nanokomposite aus Polymeren und Schichtsilikaten werden zumeist auf der Basis natürlicher Tone wie Montmorillonit hergestellt. Für NMR- und EPR-Untersuchungen der Tensidschicht, die das Silikat mit dem Polymer kompatibilisiert, ist der Eisengehalt natürlicher Tone jedoch abträglich, weil er zu einer Verkürzung der Relaxationszeiten und zu einer Linienverbreiterung in den Spektren führt. Dieses Problem konnte überwunden werden, indem als Silikatkomponente eisenfreies, strukturell wohldefiniertes Magadiit hydrothermal synthetisiert und für die Kompositbildung eingesetzt wurde. Die Morphologie des Magadiits wurde durch Rasterelektronenmikroskopie charakterisiert und der Interkalationsgrad von schmelzinterkalierten Polymer-Nanokompositen wurde durch Weitwinkelröntgenstreuung bestimmt. Polymere mit Carbonylgruppen scheinen leichter zu interkalieren als solche ohne Carbonylgruppen. Polycaprolacton interkalierte sowohl in Oragnomagadiite auf der Basis von Ammoniumtensiden als auch in solche auf der Basis von Phosphoniumtensiden. Die Dynamik auf einer Nanosekundenzeitskala und die Struktur der Tensidschicht wurden mittels ortsspezifisch spinmarkierter Tensidsonden unter Nutzung von Dauerstrich- (CW) und Puls-Methoden der elektronenparamagnetischen Resonanzspektroskopie (EPR) untersucht. Zusätzlich wurde die statische 2H-Kernmagnetresonanz (NMR) an spezifisch deuterierten Tensiden angewendet, um die Tensiddynamik auf einer komplementären Zeitskala zwischen Mikrosekunden und Millisekunden zu erfassen. Sowohl die CW-EPR- als auch die 2H-NMR-Ergebnisse zeigen eine Beschleunigung der Tensiddynamik durch Interkalation von Polycaprolacton auf, während sich in den nichtinterkalierten Mikrokompositen mit Polystyrol die Tensiddynamik verlangsamt. Die Rotationskorrelationszeiten und Aktivierungsenergien offenbaren verschiedene Regime der Tensiddynamik. In Polystyrol-Mikrokompositen entspricht die Übergangstemperatur zwischen den Regimen der Glasübergangstemperatur von Polystyrol, während sie in Polycaprolacton-Nanokompositen bei der Schmelztemperatur von Polycaprolacton liegt. Durch die erhebliche Verlängerung der Elektronenspin-Relaxationszeiten bei Verwendung von eisenfreiem Magadiit können Messdaten hoher Qualität mit Puls-EPR-Experimenten erhalten werden. Insebsondere wurden die Vier-Puls-Elektron-Elektron-Doppelresonanz (DEER), die Elektronenspinechoenveloppenmodulation (ESEEM) und die Elektronen-Kern-Doppelresonanz (ENDOR) an spinmarkierten sowie spezifisch deuterierten Tensiden angewandt. Die ENDOR-Ergebnisse legen ein Model der Tensidschicht nahe, in dem zusätzlich zu den Oberflächenlagen auf dem Silikat eine wohldefinierte mittlere Lage existiert. Dieses Modell erklärt auch Verdünnungseffekte durch das Polymer in Kompositen mit Polycaprolacton und Polystyrol. Die umfangreiche Information aus den Magnetresonanztechniken ergänzt die Information aus konventionellen Charakterisierungstechniken wie Röntgendiffraktion und Transmissionselektronenmikroskopie und führt so zu einem detaillierteren Bild der Struktur und Dynamik der Tensidschicht in Nanokompositen aus Polymeren und Schichtsilikaten.
Resumo:
Einer der Hauptschwerpunkte der Arbeit lag in der Entwicklung einer spezies-spezifischen und einer spezies-unspezifischen GC-ICP-Q-MSIVA von Schwefelspezies in Petroprodukten. Es wurden hierzu Indikatoren, ausgehend von elementarem 34S-angereichertem Schwefel, im Mikromaßstab synthetisiert. Für die spezies-spezifische GC-ICP-Q-MSIVA wurde die erstmalige Synthese von 34S-markiertem Thiophen, Dibenzothiophen und 4-Methyldibenzothiophen verwirklicht. Als Indikatorsynthese für die spezies-unspezifische GC-ICP-Q-MSIVA erfolgte die erstmalige Darstellung von 34S-angereichertem Dimethyldisulid. Mit Hilfe der synthetisierten Verbindungen wurden spezies-spezifische und spezies-unspezifische massenspektrometrische Isotopenverdünnungsanalysen von Schwefelspezies in Petroprodukten durchgeführt. Vor allen GC-ICP-Q-MSIVA-Analysen erfolgte eine umfangreiche Speziesidentifizierung durch Aufstockexperimente mit kommerziell erhältlichen Standards und mit einem mit der GC gekoppelten Elektronenstoß (EI)-MS. Beide ICP-Q-MS Methoden zeichnen sich durch sehr niedrige Nachweisgrenzen (7 ng S/g) aus, welche auch eine Anwendbarkeit auf tiefentschwefelte Kraftstoffe garantieren. Mit der spezies-unspezifischen GC-ICP-Q-MSIVA ist neben einer Speziesanalyse auch eine Gesamtschwefelanalyse durch Aufsummierung aller in der Probe vorhandenen Spezies möglich. Es wurde im Rahmen dieser Arbeit auch der Einfluss möglicher Empfindlichkeitsänderungen des ICP-Q-MS durch koeluierende Kohlenwasserstoffe überprüft, wobei diese erwartungsgemäß auf das Ergebnis der spezies-spezifischen und spezies-unspezifischen GC-ICP-Q-MSIVA keinerlei Einfluss haben. Der zweite Hauptschwerpunkt der Arbeit lag auf der Ausarbeitung routinefähiger, schneller und zuverlässiger Methoden zur Gesamtelementspurenanalytik von Schwefel und Schwermetallen in Erdölen und Petroprodukten. Für die Gesamtschwefelanalyse wurde eine MSIVA nach thermaler Verdampfung mit 34S-markierten Dibenzothiophen als Indikator entwickelt. Die neu entwickelte Methode erlaubt eine sehr schnelle Bestimmung des Gesamtschwefelgehalts, wobei die eigentliche Messung des Isotopenverhältnisses innerhalb von Sekunden nach der Injektion der Probe erfolgt. Weiterhin zeichnet sich die Methode durch Robustheit und eine niedrige Nachweisgrenze (40 ng S/g) aus. Für die Analyse von Schwermetallen wurden erstmals Möglichkeiten einer direkten MSIVA von Erdölproben ohne zeitraubenden, kontaminationsträchtigen Aufschluss bzw. die schwierige Erzeugung einer Mikroemulsion zwischen hydrophober Probe und wässrigem Indikator entwickelt. Um eine homogene Verteilung des Indikators in der hydrophoben Probe zu ermöglichen, musste ausgehend von den zur Verfügung stehenden wässrigen Indikatorlösungen, eine Überführung des Indikators in ein organisches Lösungsmittel erfolgen. Hierzu wurde der jeweilige Metallindikator unter Komplexierung aus wässrigen Metallindikatorlösungen extrahiert. Für die Analyse der mit diesen Indikatorlösungen in organischer Phase versetzten Proben wurden zwei alternative Methoden ausgearbeitet. Bei der mit der Laserablation (LA) kombinierten ICP-SF-MSIVA wird die isotopenverdünnte Probe aus einer eigens für diesen Zweck entwickelten Probenhalterung ablatiert und so dem ICP-SF-MS zugeführt wird. Bei zeitlich sich verändernden Intensitäten der gemessenen Isotope werden aber reproduzierbare und konstante Isotopenverhältnisse erhalten. Im Falle einer homogenen Verteilung der Metallspuren wurde eine hervorragende Übereinstimmung mit Vergleichsmethoden und einem Referenzmaterial festgestellt. Im Falle einer heterogenen partikulären Verteilung der Metallspuren, wie sie z.B. bei Eisenspuren in den Erdölen vorlag, ist die Anwendbarkeit der LA-ICP-SF-MSIVA aufgrund des kleinen Probenvolumens (20 µL) jedoch begrenzt. Als Alternative zur LA-ICP-SF-MSIVA wurde ein System unter Verwendung der Fließinjektion für die Zuführung der isotopenverdünnten Probe zum ICP-SF-MS ausgearbeitet. Die isotopenverdünnte Probe wird hierbei in einen Eluentenstrom von Toluol injiziert und mit Hilfe einer Total-Consumption-Zerstäuber/Sprühkammer-Einheit vollständig bei einer Flussrate von 10 µL/min in das Plasma eingebracht. Neben einer nochmaligen Verkürzung der Analysenzeit und Vereinfachung der Probenvorbereitung bietet diese Methode zusätzlich stark verbesserte Nachweisgrenzen (z.B. Ni 0,9 ng/g). Leider sind mit diesem Verfahren bis jetzt nur Ni und Mo zuverlässig bestimmbar. Das in dieser Arbeit ausgearbeitete Methodenpaket erlaubt erstmals eine breite Einführung der ICP-MSIVA als zuverlässige Methode in die Routineanalytik der Petroindustrie. Durch die bewiesene Zuverlässigkeit, den geringen Zeitaufwand und die Robustheit der Methoden steht ihrem routinemäßigen Einsatz, außer einer weitergehenderen Automatisierung einzelner Verfahrensteile, prinzipiell nichts entgegen.