4 resultados para Pulse Transit Time

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

80.00% 80.00%

Publicador:

Resumo:

A series of new columnar discotic liquid crystalline materials based on the superphenalene (C96) core has been synthesized by oxidative cyclodehydrogenation with iron(III) chloride of suitable three-dimensional oligophenylene precursors. These compounds were investigated by means of differential scanning calorimetry (DSC), polarized optical microscopy (POM) and wide angle X-ray scattering (WAXS), and showed highly ordered supramolecular arrays and mesophase behavior over a broad temperature range. Good solubility, through the introduction of long alkyl chains, and the fact that these new superphenalene derivatives were found to be liquid crystalline at room temperature enabled the formation of highly ordered films (using the zone-casting technique), a requirement for application in organic electronic devices. The one-dimensional, intracolumnar charge carrier mobilities of superphenalene derivatives were determined using the pulse-radiolysis time-resolved microwave conductivity technique (PR-TRMC). Electrical properties of different C96-C12 architectures on mica surfaces were examined by using Electrostatic Force Microscopy (EFM) and Kelvin Probe Force Microscopy (KPFM). Hexa-peri-hexabenzocoronene (C42) derivatives substituted at the periphery with six branched alkyl ether chains were also synthesized. It was found that the introduction of ether groups within the side chains enhances the affinity of the discotic molecules towards polar surfaces, resulting in homeotropic self-assembly (as shown by POM and 2D-WAXS) when the compounds are processed from the isotropic state between two surfaces. A new, insoluble, superphenalene building block bearing six reactive sites was prepared, and was further used for the preparation of dendronized superphenalenes with bulky dendritic substituents around the core. UV/Vis and fluorescence experiments suggest reduced π-π stacking of the superphenalene cores as a result of steric hindrance between the peripheral dendritic units. A new family of graphitic molecules with partial ”zig-zag” periphery has been established. The incorporation of ”zig-zag” edges was shown to have a strong influence on the electronic properties of the new molecules (as studied by solution and solid-state UV/Vis, and fluorescence spectroscopy), leading to a significant bathochromic shift with respect to the parent PAHs (C42 and C96). The reactivity of the additional double bonds was examined. The attachment of long alkyl chains to a ”zig-zag” superphenalene core afforded a new, processable, liquid crystalline material.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Das Aerosolmassenspektrometer SPLAT (Single Particle Laser Ablation Time-of-Flight Mass Spectrometer) ist in der Lage, die Größe einzelner Aerosolpartikel in einem Größenbereich von 0,3 µm bis 3 µm zu bestimmen und gleichzeitig chemisch zu analysieren. Die Größenbestimmung erfolgt durch Streulichtmessung und Bestimmung der Flugzeit der Partikel zwischen zwei kontinuierlichen Laserstrahlen. Durch Kalibrationsmessungen kann auf den aerodynamischen Durchmesser der Partikel geschlossen werden. Kurzzeitig nach der Streulichtdetektion werden die Partikel durch einen hochenergetischen gepulsten UV-Laser verdampft und ionisiert. Die Flugzeit der Partikel zwischen den kontinuierlichen Laserstrahlen wird dazu benutzt, die Ankunftszeit der Partikel in der Ionenquelle zu berechnen und den UV-Laserpuls zu zünden. Die entstandenen Ionen werden in einem bipolaren Flugzeitmassen¬spektrometer nachgewiesen. Durch die Laserablation/Ionisation ist das SPLAT in der Lage, auch schwer verdampfbare Komponenten des atmosphärischen Aerosols - wie etwa Minerale oder Metalle - nachzuweisen. Das SPLAT wurde während dieser Arbeit vollständig neu entwickelt und aufgebaut. Dazu gehörten das Vakuum- und Einlasssystem, die Partikeldetektion, die Ionenquelle und das Massen-spektrometer. Beim Design des SPLAT wurde vor allem auf den späteren Feldeinsatz Wert gelegt, was besondere Anforderungen an Mechanik und Elektronik stellte. Die Charakterisierung der einzelnen Komponenten sowie des gesamten Instruments wurde unter Laborbedingungen durchgeführt. Dabei wurde u.a. Detektionseffizienzen des Instruments ermittelt, die abhängig von der Größe der Partikel sind. Bei sphärischen Partikeln mit einem Durchmesser von 600 nm wurden ca. 2 % der Partikel die in das Instrument gelangten, detektiert und chemisch analysiert. Die Fähigkeit zum Feldeinsatz hat das SPLAT im Februar/März 2006 während einer internationalen Messkampagne auf dem Jungfraujoch in der Schweiz bewiesen. Auf dieser hochalpinen Forschungsstation in einer Höhe von ca. 3580 m fand das SPLAT mineralische und metallische Komponenten in den Aerosolpartikeln. Das SPLAT ist ein vielfältig einsetzbares Instrument und erlaubt vor allem in Kombination mit Aerosolmassenspektrometern, die mit thermischer Verdampfung und Elektronenstoßionisation arbeiten, einen Erkenntnisgewinn in der Analytik atmosphärischer Aerosolpartikel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Time-of-flight photoemission spectromicroscopy was used to measure and compare the two-photon photoemission (2PPE) spectra of Cu and Ag nanoparticles with linear dimensions ranging between 40 nm and several 100 nm, with those of the corresponding homogeneous surfaces. 2PPE was induced employing femtosecond laser radiation from a frequency-doubled Ti:sapphire laser in the spectral range between 375 nm and 425 nm with a pulse width of 200 fs and a repetition rate of 80 MHz. The use of a pulsed radiation source allowed us to use a high-resolution photoemission electron microscope as imaging time-of-flight spectrometer, and thus to obtain spectroscopic information about the laterally resolved electron signal. Ag nanoparticle films have been deposited on Si(111) by electron-beam evaporation, a technique leading to hemispherically-shaped Ag clusters. Isolated Cu nanoparticles have been generated by prolonged heating of a polycrystalline Cu sample. If compared to the spectra of the corresponding homogeneous surfaces, the Cu and Ag nanoparticle spectra are characterized by a strongly enhanced total 2PPE yield (enhancement factor up to 70), by a shift (about 0.1 eV) of the Fermi level onset towards lower final state energies, by a reduction of the work function (typically by 0.2 eV) and by a much steeper increase of the 2PPE yield towards lower final state energies. The shift of the Fermi level onset in the nanoparticle spectra has been explained by a positive unit charge (localized photohole) residing on the particle during the time-scale relevant for the 2PPE process (few femtoseconds). The total 2PPE yield enhancement and the different overall shape of the spectra have been explained by considering that the laser frequency was close to the localized surface plasmon resonance of the Cu and Ag nanoparticles. The synchronous oscillations induced by the laser in the metal electrons enhance the near-zone (NZ) field, defined as the linear superposition of the laser field and the field produced in the vicinity of the particles by the forced charge oscillations. From the present measurements it is clear that the NZ field behavior is responsible for the 2PPE enhancement and affects the 2PPE spatial and energy distribution and its dynamics. In particular, its strong spatial dependence allows indirect transitions through real intermediate states to take place in the metal clusters. Such transitions are forbidden by momentum conservation arguments and are thus experimentally much less probable on homogeneous surfaces. Further, we investigated specially tailored moon-shaped small metal nanostructures, whose NZ field was theoretically predicted, and compared the calculation with the laterally resolved 2PPE signal. We could show that the 2PPE signal gives a clear fingerprint of the theoretically predicted spatial dependence of the NZ field. This potential of our method is highly attractive in the novel field of plasmonics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Within this thesis a new double laser pulse pumping scheme for plasma-based, transient collisionally excited soft x-ray lasers (SXRL) was developed, characterized and utilized for applications. SXRL operations from ~50 up to ~200 electron volt were demonstrated applying this concept. As a central technical tool, a special Mach-Zehnder interferometer in the chirped pulse amplification (CPA) laser front-end was developed for the generation of fully controllable double-pulses to optimally pump SXRLs.rnThis Mach-Zehnder device is fully controllable and enables the creation of two CPA pulses of different pulse duration and variable energy balance with an adjustable time delay. Besides the SXRL pumping, the double-pulse configuration was applied to determine the B-integral in the CPA laser system by amplifying short pulse replica in the system, followed by an analysis in the time domain. The measurement of B-integral values in the 0.1 to 1.5 radian range, only limited by the reachable laser parameters, proved to be a promising tool to characterize nonlinear effects in the CPA laser systems.rnContributing to the issue of SXRL pumping, the double-pulse was configured to optimally produce the gain medium of the SXRL amplification. The focusing geometry of the two collinear pulses under the same grazing incidence angle on the target, significantly improved the generation of the active plasma medium. On one hand the effect was induced by the intrinsically guaranteed exact overlap of the two pulses on the target, and on the other hand by the grazing incidence pre-pulse plasma generation, which allows for a SXRL operation at higher electron densities, enabling higher gain in longer wavelength SXRLs and higher efficiency at shorter wavelength SXRLs. The observation of gain enhancement was confirmed by plasma hydrodynamic simulations.rnThe first introduction of double short-pulse single-beam grazing incidence pumping for SXRL pumping below 20 nanometer at the laser facility PHELIX in Darmstadt (Germany), resulted in a reliable operation of a nickel-like palladium SXRL at 14.7 nanometer with a pump energy threshold strongly reduced to less than 500 millijoule. With the adaptation of the concept, namely double-pulse single-beam grazing incidence pumping (DGRIP) and the transfer of this technology to the laser facility LASERIX in Palaiseau (France), improved efficiency and stability of table-top high-repetition soft x-ray lasers in the wavelength region below 20 nanometer was demonstrated. With a total pump laser energy below 1 joule the target, 2 mircojoule of nickel-like molybdenum soft x-ray laser emission at 18.9 nanometer was obtained at 10 hertz repetition rate, proving the attractiveness for high average power operation. An easy and rapid alignment procedure fulfilled the requirements for a sophisticated installation, and the highly stable output satisfied the need for a reliable strong SXRL source. The qualities of the DGRIP scheme were confirmed in an irradiation operation on user samples with over 50.000 shots corresponding to a deposited energy of ~ 50 millijoule.rnThe generation of double-pulses with high energies up to ~120 joule enabled the transfer to shorter wavelength SXRL operation at the laser facility PHELIX. The application of DGRIP proved to be a simple and efficient method for the generation of soft x-ray lasers below 10 nanometer. Nickel-like samarium soft x-ray lasing at 7.3 nanometer was achieved at a low total pump energy threshold of 36 joule, which confirmed the suitability of the applied pumping scheme. A reliable and stable SXRL operation was demonstrated, due to the single-beam pumping geometry despite the large optical apertures. The soft x-ray lasing of nickel-like samarium was an important milestone for the feasibility of applying the pumping scheme also for higher pumping pulse energies, which are necessary to obtain soft x-ray laser wavelengths in the water window. The reduction of the total pump energy below 40 joule for 7.3 nanometer short wavelength lasing now fulfilled the requirement for the installation at the high-repetition rate operation laser facility LASERIX.rn