5 resultados para Liquid-liquid flow
em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha
Resumo:
Understanding liquid flow at the vicinity of solid surfaces is crucial to the developmentrnof technologies to reduce drag. One possibility to infer flow properties at the liquid-solid interface is to compare the experimental results to solutions of the Navier-Stokes equations assuming the no-slip boundary condition (BC) or the slip BC. There is no consensus in the literature about which BC should be used to model the flow of aqueous solutions over hydrophilic surfaces. Here, the colloidal probe technique is used to systematically address this issue, measuring forces acting during drainage of water over a surface. Results show that experimental variables, especially the cantilever spring constant, lead to the discrepancy observed in the literature. Two different parameters, calculated from experimental variables, could be used to separate the data obtained in this work and those reported in the literature in two groups: one explained with the no-slip BC, and another with the slip BC. The observed residual slippage is a function of instrumental variables, showing a trend incompatible with the available physical justifications. As a result, the no-slip is the more appropriate BC. The parameters can be used to avoid situations where the no-slip BC is not satisfied.
Resumo:
Die pneumatische Zerstäubung ist die häufigste Methode der Probenzuführung von Flüssigkeiten in der Plasmaspektrometrie. Trotz der bekannten Limitierungen dieser Systeme, wie die hohen Probenverluste, finden diese Zerstäuber aufgrund ihrer guten Robustheit eine breite Anwendung. Die flussratenabhängige Aerosolcharakteristik und pumpenbasierte Signalschwankungen limitieren bisher Weiterentwicklungen. Diese Probleme werden umso gravierender, je weiter die notwendige Miniaturisierung dieser Systeme fortschreitet. Der neuartige Ansatz dieser Arbeit basiert auf dem Einsatz modifizierter Inkjet-Druckerpatronen für die Dosierung von pL-Tropfen. Ein selbst entwickelter Mikrokontroller ermöglicht den Betrieb von matrixkodierten Patronen des Typs HP45 mit vollem Zugriff auf alle essentiellen Betriebsparameter. Durch die neuartige Aerosoltransportkammer gelang die effiziente Kopplung des Tropfenerzeugungssystems an ein ICP-MS. Das so aufgebaute drop-on-demand-System (DOD) zeigt im Vergleich zu herkömmlichen und miniaturisierten Zerstäubern eine deutlich gesteigerte Empfindlichkeit (8 - 18x, elementabhängig) bei leicht erhöhtem, aber im Grunde vergleichbarem Signalrauschen. Darüber hinaus ist die Flexibilität durch die große Zahl an Freiheitsgraden des Systems überragend. So ist die Flussrate über einen großen Bereich variabel (5 nL - 12,5 µL min-1), ohne dabei die primäre Aerosolcharakteristik zu beeinflussen, welche vom Nutzer durch Wahl der elektrischen Parameter bestimmt wird. Das entwickelte Probenzuführungssystem ist verglichen mit dem pneumatischen Referenzsystem weniger anfällig gegenüber Matrixeffekten beim Einsatz von realen Proben mit hohen Anteilen gelöster Substanzen. So gelingt die richtige Quantifizierung von fünf Metallen im Spurenkonzentrationsbereich (Li, Sr, Mo, Sb und Cs) in nur 12 µL Urin-Referenzmaterial mittels externer Kalibrierung ohne Matrixanpassung. Wohingegen beim pneumatischen Referenzsystem die aufwändigere Standardadditionsmethode sowie über 250 µL Probenvolumen für eine akkurate Bestimmung der Analyten nötig sind. Darüber hinaus wird basierend auf der Dosierfrequenz eines dualen DOD-Systems eine neuartige Kalibrierstrategie vorgestellt. Bei diesem Ansatz werden nur eine Standard- und eine Blindlösung anstelle einer Reihe unterschiedlich konzentrierter Standards benötigt, um eine lineare Kalibrierfunktion zu erzeugen. Zusätzlich wurde mittels selbst entwickelter, zeitlich aufgelöster ICP-MS umfangreiche Rauschspektren aufgenommen. Aus diesen gelang die Ermittlung der Ursache des erhöhten Signalrauschens des DOD, welches maßgeblich durch das zeitlich nicht äquidistante Eintreffen der Tropfen am Detektor verursacht wird. Diese Messtechnik erlaubt auch die Detektion einzeln zugeführter Tropfen, wodurch ein Vergleich der Volumenverteilung der mittels ICP-MS detektierten, gegenüber den generierten und auf optischem Wege charakterisierten Tropfen möglich wurde. Dieses Werkzeug ist für diagnostische Untersuchungen äußerst hilfreich. So konnte aus diesen Studien neben der Aufklärung von Aerosoltransportprozessen die Transporteffizienz des DOD ermittelt werden, welche bis zu 94 Vol.-% beträgt.
Resumo:
Five different methods were critically examined to characterize the pore structure of the silica monoliths. The mesopore characterization was performed using: a) the classical BJH method of nitrogen sorption data, which showed overestimated values in the mesopore distribution and was improved by using the NLDFT method, b) the ISEC method implementing the PPM and PNM models, which were especially developed for monolithic silicas, that contrary to the particulate supports, demonstrate the two inflection points in the ISEC curve, enabling the calculation of pore connectivity, a measure for the mass transfer kinetics in the mesopore network, c) the mercury porosimetry using a new recommended mercury contact angle values. rnThe results of the characterization of mesopores of monolithic silica columns by the three methods indicated that all methods were useful with respect to the pore size distribution by volume, but only the ISEC method with implemented PPM and PNM models gave the average pore size and distribution based on the number average and the pore connectivity values.rnThe characterization of the flow-through pore was performed by two different methods: a) the mercury porosimetry, which was used not only for average flow-through pore value estimation, but also the assessment of entrapment. It was found that the mass transfer from the flow-through pores to mesopores was not hindered in case of small sized flow-through pores with a narrow distribution, b) the liquid penetration where the average flow-through pore values were obtained via existing equations and improved by the additional methods developed according to Hagen-Poiseuille rules. The result was that not the flow-through pore size influences the column bock pressure, but the surface area to volume ratio of silica skeleton is most decisive. Thus the monolith with lowest ratio values will be the most permeable. rnThe flow-through pore characterization results obtained by mercury porosimetry and liquid permeability were compared with the ones from imaging and image analysis. All named methods enable a reliable characterization of the flow-through pore diameters for the monolithic silica columns, but special care should be taken about the chosen theoretical model.rnThe measured pore characterization parameters were then linked with the mass transfer properties of monolithic silica columns. As indicated by the ISEC results, no restrictions in mass transfer resistance were noticed in mesopores due to their high connectivity. The mercury porosimetry results also gave evidence that no restrictions occur for mass transfer from flow-through pores to mesopores in the small scaled silica monoliths with narrow distribution. rnThe prediction of the optimum regimes of the pore structural parameters for the given target parameters in HPLC separations was performed. It was found that a low mass transfer resistance in the mesopore volume is achieved when the nominal diameter of the number average size distribution of the mesopores is appr. an order of magnitude larger that the molecular radius of the analyte. The effective diffusion coefficient of an analyte molecule in the mesopore volume is strongly dependent on the value of the nominal pore diameter of the number averaged pore size distribution. The mesopore size has to be adapted to the molecular size of the analyte, in particular for peptides and proteins. rnThe study on flow-through pores of silica monoliths demonstrated that the surface to volume of the skeletons ratio and external porosity are decisive for the column efficiency. The latter is independent from the flow-through pore diameter. The flow-through pore characteristics by direct and indirect approaches were assessed and theoretical column efficiency curves were derived. The study showed that next to the surface to volume ratio, the total porosity and its distribution of the flow-through pores and mesopores have a substantial effect on the column plate number, especially as the extent of adsorption increases. The column efficiency is increasing with decreasing flow through pore diameter, decreasing with external porosity, and increasing with total porosity. Though this tendency has a limit due to heterogeneity of the studied monolithic samples. We found that the maximum efficiency of the studied monolithic research columns could be reached at a skeleton diameter of ~ 0.5 µm. Furthermore when the intention is to maximize the column efficiency, more homogeneous monoliths should be prepared.rn
Resumo:
Liquid crystalline elastomers (LCEs) are known to perform a reversible change of shape upon the phase transition from the semi-ordered liquid crystalline state to the chaotic isotropic state. This unique behavior of these “artificial muscles” arises from the self-organizing properties of liquid crystals (mesogens) in combination with the entropy-elasticity of the slightly crosslinked elastomer network. In this work, micrometer-sized LCE actuators are fabricated in a microfluidic setup. The microtubular shear flow provides for a uniform orientation of the mesogens during the crosslinking, a perquisite for obtaining actuating LCE samples. The scope of this work was to design different actuator geometries and to broaden the applicability of the microfluidic device for different types of liquid crystalline mesogens, ranging from side-chain to main-chain systems, as well as monomer and polymer precursors. For example, the thiol-ene “click” mechanism was used for the polymerization and crosslinking of main-chain LCE actuators. The main focus was, however, placed on acrylate monomers and polymers with LC side chains. A LC polymer precursor, comprising mesogenic and crosslinkable side-chains was synthesized. Used in combination with an LC monomer, the polymeric crosslinker promoted a stable LC phase, which allowed the mixture to be isothermally handled in the microfluidic reactor. If processed without the additional LC components, the polymer precursor yielded actuating fibers. A suitable co-flowing continuous phase facilitates the formation of a liquid jet and lowers the tendency for drop formation. By modification of the microfluidic device, it was further possible to prepare core-shell particles, comprised of an LCE shell and filled with an isotropic liquid. In analogy to the heart, a hollow muscle, the elastomer shell expels the inner liquid core upon its contraction. The feasibility of the core-shell particles as micropumps was demonstrated. In general, the synthesized LCE microactuators may be utilized as active components in micromechanical and lab-on-chip systems.
Resumo:
In this thesis cholesteric films made of liquid crystalline cellulose derivatives with improved optical properties were prepared. The choice of the solvent, hydrogen bond influencing additives, the synthetic realization of a very high degree of substitution on the cellulosic polymer and the use of mechanical stirring at the upper concentration limit of the liquid crystalline range were the basis for an improved alignment of the applied cellulose tricarbamates. In combination with a tuned substrate treatment and film preparation method, cholesteric films were obtained, with optical properties that were theoretically predicted and only known from low molecular weight liquid crystals so far. Subsequent polymerization allowed a permanent fixing of the alignment and the fabrication of free standing and insensitive films.rnThe incorporation of inorganic nanorods into the cholesteric host material was mediated with tailored block copolymers, available via controlled radical polymerization methods. In addition to the shape match between the rodlike mesogens of the host and the nanorods it was possible to increase the miscibility of both materials. Nevertheless, the size of the nanorods, in comparison to the mesogens, in these densely packed liquid crystalline phases as well as their long equilibration times were the reasons for phase separation. Nanorods are, in principle, valuable substitutes for organics, but their utilization in cellulosic CLC was not to be combined with a high quality alignment of the cholesteric structure.rnA swelling process of polymerized films in a dye solution or dissolving dyes in non-polymerized CLC was used for incorporation of the organic chromophores. With the first method the CLC could be aligned and polymerized without any disturbance due to dye molecules. The optical properties of dye and CLC were matched, with regard to mirrorless lasing devices. The dye was optically excited and laser emission supported by the cholesteric cavity was obtained. The polarization and wavelength of the emitted radiation as well as its bandwidth, the obtained interference pattern and threshold behavior of the emission proofed the feedback mechanism that was not believed to be realizable in liquid crystalline polymers. rnUtilization of a microfluidic co-flow injection device enabled us to transfer the properties of cellulosic CLC from the planar film shape to spherical micrometer sized particles. The pure material yielded particles with distorted mesogen alignment similar to films prepared by capillary flow. Dilution of the CLC with a solvent that migrated into the carrier phase during particle preparation provided the basis for particles with well ordered areas. rnAlthough cellulose derivatives were known for their liquid crystalline behavior for decades and synthesized in mass production, their application as feedback material was affected by bad optical properties. In comparison to low molar mass compounds, the low degree of order in the CLC phase was the cause. With the improved material, defined lasing emission was shown and characterized. Derivatives of cellulose are desirable materials, because, as a renewable resource, they are available in large amounts for a low price and need only simple derivatization reactions. The fabrication of CLC films with tunable lasing emission, for which this thesis can provide a starting point, is in good agreement with today's requirements of modern technology and its miniaturization.rn