12 resultados para CAPILLARY ELECTROPHORESIS-MASS SPECTROMETRY
em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha
Resumo:
An accurate and sensitive species-specific GC-ICP-IDMS (gas chromatography inductively coupled plasma isotope dilution mass spectrometry) method for the determination of trimethyllead and a multi-species-specific GC-ICP-IDMS method for the simultaneous determination of trimethyllead, methylmercury, and butyltins in biological and environmental samples were developed. They allow the determination of corresponding elemental species down to the low ng g-1 range. The developed synthesis scheme for the formation of isotopically labeled Me3206Pb+ can be used for future production of this spike. The novel extraction technique, stir bar sorptive extraction (SBSE), was applied for the first time in connection with species-specific isotope dilution GC-ICP-MS for the determination of trimethyllead, methylmercury and butyltins. The results were compared with liquid-liquid extraction. The developed methods were validated by the analysis of certified reference materials. The liquid-liquid extraction GC-ICP-IDMS method was applied to seafood samples purchased from a supermarket. The methylated lead fraction in these samples, correlated to total lead, varied in a broad range of 0.01-7.6 %. On the contrary, the fraction of methylmercury is much higher, normally in the range of 80-98 %. The highest methylmercury content of up to 12 µg g-1 has been determined in shark samples, an animal which is at the end of the marine food chain, whereas in other seafood samples a MeHg+ content of less than 0.2 µg g-1 was found. Butyltin species could only be determined in samples, where anthropogenic contaminations must be assumed. This explains the observed broad variation of the butylated tin fraction in the range of <0.3-49 % in different seafood samples. Because all isotope-labelled spike compounds, except trimethyllead, are commercially available, the developed multi-species-specific GC-ICP-IDMS method has a high potential in future for routine analysis.
Resumo:
Within this PhD thesis matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) has been used as a reliable tool for the quantitative characterization of giant molecules, such as alkyl substituted and unsubstituted large polycyclic aromatic hydrocarbons (PAH), which cannot be characterized by conventional analytic techniques due to their lack of solubility. The use of the MALDI solvent-free technique for the sample preparation and the application of the standard addition method have allowed the quantitative characterization of synthetic PAH mixtures. The knowledge, acquired by studying these representative systems, has been then transferred to the quantitative analyses of complex and slightly soluble natural PAH mixtures, such as mesophase pitch. Moreover, the possibility to ionize intractable and insoluble molecules via mass spectrometry has been recognized to be not only a powerful analytical method, but also to represent a unique change to handle giant aromatic systems and to deposit them on a surface for further investigations, in a process, which is defined as “soft-landing”. Within this novel deposition technique, ions of the desired analytes or analyte mixtures are generated by means of an MS ionization source, discriminated by their different mass to charge ratios via a mass analyzer and landed with retention of their structure on a desired surface. This soft-deposition is guaranteed by the use of decelerating potentials, which have in this work been recognized to influence the final packing of the analyte molecules reaching the landing surface. For a more detailed study of the electrical field action on disc-like and rod-like molecules, soft-landing-independent experiments have been additionally carried out. As a result unidirectionally ordered films of the analyte molecules have been obtained due to the application of an external electrical strength. This versatile alignment technique has then been used for obtaining ordered layers of semiconducting materials for the fabrication of organic field effect transistors (OFET) with improved performances.
Resumo:
Heutzutage gewähren hochpräzise Massenmessungen mit Penning-Fallen tiefe Einblicke in die fundamentalen Eigenschaften der Kernmaterie. Zu diesem Zweck wird die freie Zyklotronfrequenz eines Ions bestimmt, das in einem starken, homogenen Magnetfeld gespeichert ist. Am ISOLTRAP-Massenspektrometer an ISOLDE / CERN können die Massen von kurzlebigen, radioaktiven Nukliden mit Halbwertszeiten bis zu einigen zehn ms mit einer Unsicherheit in der Größenordnung von 10^-8 bestimmt werden. ISOLTRAP besteht aus einem Radiofrequenz-Quadrupol zum akkumulieren der von ISOLDE gelieferten Ionen, sowie zwei Penning-Fallen zum säubern und zur Massenbestimmung der Ionen. Innerhalb dieser Arbeit wurden die Massen von neutronenreichen Xenon- und Radonisotopen (138-146Xe und 223-229Rn) gemessen. Für elf davon wurde zum ersten Mal die Masse direkt bestimmt; 229Rn wurde im Zuge dieses Experimentes sogar erstmalig beobachtet und seine Halbwertszeit konnte zu ungefähr 12 s bestimmt werden. Da die Masse eines Nuklids alle Wechselwirkungen innerhalb des Kerns widerspiegelt, ist sie einzigartig für jedes Nuklid. Eine dieser Wechselwirkungen, die Wechselwirkung zwischen Protonen und Neutronen, führt zum Beispiel zu Deformationen. Das Ziel dieser Arbeit ist eine Verbindung zwischen kollektiven Effekten, wie Deformationen und Doppeldifferenzen von Bindungsenergien, sogenannten deltaVpn-Werten zu finden. Insbesondere in den hier untersuchten Regionen zeigen deltaVpn-Werte ein sehr ungewöhnliches Verhalten, das sich nicht mit einfachen Argumenten deuten lässt. Eine Erklärung könnte das Auftreten von Oktupoldeformationen in diesen Gebieten sein. Nichtsdestotrotz ist eine quantitative Beschreibung von deltaVpn-Werten, die den Effekt von solchen Deformationen berücksichtigt mit modernen Theorien noch nicht möglich.
Resumo:
In this study the Aerodyne Aerosol Mass Spectrometer (AMS) was used during three laboratory measurement campaigns, FROST1, FROST2 and ACI-03. The FROST campaigns took place at the Leipzig Aerosol Cloud Interaction Simulator (LACIS) at the IfT in Leipzig and the ACI-03 campaign was conducted at the AIDA facility at the Karlsruhe Institute of Technology (KIT). In all three campaigns, the effect of coatings on mineral dust ice nuclei (IN) was investigated. During the FROST campaigns, Arizona Test Dust (ATD) particles of 200, 300 and 400 nm diameter were coated with thin coatings (< 7 nm) of sulphuric acid. At these very thin coatings, the AMS was operated close to its detection limits. Up to now it was not possible to accurately determine AMS detection limits during regular measurements. Therefore, the mathematical tools to analyse the detection limits of the AMS have been improved in this work. It is now possible to calculate detection limits of the AMS under operating conditions, without losing precious time by sampling through a particle filter. The instrument was characterised in more detail to enable correct quantification of the sulphate loadings on the ATD particle surfaces. Correction factors for the instrument inlet transmission, the collection efficiency, and the relative ionisation efficiency have been determined. With these corrections it was possible to quantify the sulphate mass per particle on the ATD after the condensation of sulphuric acid on its surface. The AMS results have been combined with the ice nucleus counter results. This revealed that the IN-efficiency of ATD is reduced when it is coated with sulphuric acid. The reason for this reduction is a chemical reaction of sulphuric acid with the particle's surface. These reactions are increasingly taking place when the aerosol is humidified or heated after the coating with sulphuric acid. A detailed analysis of the solubility and the evaporation temperature of the surface reaction products revealed that most likely aluminium sulphate is produced in these reactions.
Resumo:
The composition of the atmosphere is frequently perturbed by the emission of gaseous and particulate matter from natural as well as anthropogenic sources. While the impact of trace gases on the radiative forcing of the climate is relatively well understood the role of aerosol is far more uncertain. Therefore, the study of the vertical distribution of particulate matter in the atmosphere and its chemical composition contribute valuable information to bridge this gap of knowledge. The chemical composition of aerosol reveals information on properties such as radiative behavior and hygroscopicity and therefore cloud condensation or ice nucleus potential. rnThis thesis focuses on aerosol pollution plumes observed in 2008 during the POLARCAT (Polar Study using Aircraft, Remote Sensing, Surface Measurements and Models, of Climate, Chemistry, Aerosols, and Transport) campaign over Greenland in June/July and CONCERT (Contrail and Cirrus Experiment) campaign over Central and Western Europe in October/November. Measurements were performed with an Aerodyne compact time-of-flight aerosol mass spectrometer (AMS) capable of online size-resolved chemical characterization of non-refractory submicron particles. In addition, the origins of pollution plumes were determined by means of modeling tools. The characterized pollution episodes originated from a large variety of sources and were encountered at distinct altitudes. They included pure natural emissions from two volcanic eruptions in 2008. By the time of detection over Western Europe between 10 and 12 km altitude the plume was about 3 months old and composed to 71 % of particulate sulfate and 21 % of carbonaceous compounds. Also, biomass burning (BB) plumes were observed over Greenland between 4 and 7 km altitude (free troposphere) originating from Canada and East Siberia. The long-range transport took roughly one and two weeks, respectively. The aerosol was composed of 78 % organic matter and 22 % particulate sulfate. Some Canadian and all Siberian BB plumes were mixed with anthropogenic emissions from fossil fuel combustion (FF) in North America and East Asia. It was found that the contribution of particulate sulfate increased with growing influences from anthropogenic activity and Asia reaching up to 37 % after more than two weeks of transport time. The most exclusively anthropogenic emission source probed in the upper troposphere was engine exhaust from commercial aircraft liners over Germany. However, in-situ characterization of this aerosol type during aircraft chasing was not possible. All long-range transport aerosol was found to have an O:C ratio close to or greater than 1 implying that low-volatility oxygenated organic aerosol was present in each case despite the variety of origins and the large range in age from 3 to 100 days. This leads to the conclusion that organic particulate matter reaches a final and uniform state of oxygenation after at least 3 days in the free troposphere. rnExcept for aircraft exhaust all emission sources mentioned above are surface-bound and thus rely on different types of vertical transport mechanisms, such as direct high altitude injection in the case of a volcanic eruption, or severe BB, or uplift by convection, to reach higher altitudes where particles can travel long distances before removal mainly caused by cloud scavenging. A lifetime for North American mixed BB and FF aerosol of 7 to 11 days was derived. This in consequence means that emission from surface point sources, e.g. volcanoes, or regions, e.g. East Asia, do not only have a relevant impact on the immediate surroundings but rather on a hemispheric scale including such climate sensitive zones as the tropopause or the Arctic.
Resumo:
Die Elemente Uran und Plutonium besitzen seit Entdeckung der Kernspaltung und der technischen Nutzung der Kernenergie eine globale Bedeutung. So trägt Pu hauptsächlich zur Radiotoxizität von abgebrannten Brennelementen bei und erfordert im Falle einer Endlagerung in einer tiefen geologischen Formation einen sicheren Verschluss für bis zu einer Million Jahre. Das Wissen über die vorliegenden chemischen Spezies ist dabei entscheidend für das Verständnis der chemisch-physikalischen Wechselwirkungen im jeweiligen geochemischen System, insbesondere mit dem Wirtsgestein (hier Ton) und den allgegenwärtigen Huminstoffen (hier Fulvinsäure). Längerfristig sind so Vorhersagen über einen Transport des hochradioaktiven Abfalls nach Auslaugung und Austritt aus einem Endlager bis in die Biosphäre möglich. Gerade der Ultraspurenbereich, im Fernfeld eines Endlagers zu erwarten, ist dabei von besonderem Interesse. Darüber hinaus machen nuklearforensische Untersuchungen – in Hinblick auf illegal benutztes Nuklearmaterial, Schmuggel oder Nuklearterrorismus – zur Bestimmung der Herkunft, des Alters oder der Radiotoxizität isotopenselektive Nachweismethoden im Ultraspurenbereich notwendig. Im Rahmen dieser Arbeit wurden hierfür die Resonanzionisationsmassenspektrometrie (RIMS) zur isotopenselektiven Spuren- und Ultraspurenanalyse von U und Pu sowie die Kapillarelektrophorese (CE) gekoppelt an die induktiv gekoppelte Plasma (ICP)-Massenspektrometrie (CE-ICP-MS) zur Speziation von Pu eingesetzt. Für den isotopenselektiven Nachweis von Ultraspurenmengen von Uran mittels RIMS wurden vorbereitende Studien durchgeführt und mehrere zweifach resonante Anregungsleitern mit nicht-resonanter Ionisation untersucht. Eine Effizienz von ca. 10^-10 bei einer Nachweisgrenze von 10^12 Atomen U-238 konnte erzielt werden. In Zusammenarbeit mit dem Institut für Radiochemie, TU München, wurde mittels RIMS die Isotopenzusammensetzung von Plutonium, abgetrennt aus einem panzerbrechenden Urangeschoss aus dem Kosovokonflikt, bestimmt und dieses als Waffenplutonium mit einem Gehalt von 15 pg Pu-239/g Uran identifiziert. Rückschlüsse über Herkunft und Alter des Plutoniums konnten daraus gewonnen werden. Für Studien zur Umweltüberwachung von Plutonium in Rheinland-Pfalz wurden Grund-, Oberflächen- und Klärwasserproben mittels RIMS untersucht. Oberhalb der Nachweisgrenze von ca. 10^7 Atomen Pu-239/500 mL konnte kein signifikanter Gehalt bestimmt werden. Zusätzlich wurden Klärschlammproben untersucht, wobei in einer Probe 5,1*10^7 Atome Pu-239/g gemessen wurde, was auf eine Anreicherung von Pu im Klärschlamm aus großen Wasservolumina hindeuten könnte. Speziationsuntersuchungen von Plutonium in Kontakt mit Fulvinsäure und dem Tonmineral Kaolinit wurden in Hinblick auf die Wechselwirkungen im Umfeld eines nuklearen Endlagers durchgeführt. Die Redoxkinetik von Pu(VI) in Kontakt mit Gorleben-Fulvinsäure zeigt eine mit steigendem pH zunehmend schnellere und vollständige Reduktion und ein vergleichbares Verhalten zur Huminsäure. Für ein Plutoniumgemisch aus allen vier umweltrelevanten Oxidationsstufen in Kontakt mit Gorleben-Fulvinsäure konnte nach ca. 1 Monat Kontaktzeit eine fasst vollständige Reduktion zum tri- und tetravalenten Pu beobachtet werden. Sorptionsuntersuchungen der stabilsten Oxidationsstufe, Pu(IV), in Kontakt mit Kaolinit bei pH = 0 bis 13 im Konzentrationsbereich 10^-7 bis 10^-9 mol/L verdeutlichen das ausgeprägte Sorptionsverhalten von Pu(IV) (ca. 60% bis 90% Sorption) im umweltrelevanten pH-Bereich bei einem Einsetzen der Sorption bei pH = 0 bis 2. Im Rahmen des "Colloid and Radionuclide Retardation" (CRR) Experiments im Felslabor Grimsel, Schweizer Alpen, wurde in Zusammenarbeit mit dem Institut für Nukleare Entsorgung, Karlsruhe, die kolloidgetragene Migration von Pu(IV) in einem Grundwasserstrom durch Scherzonen im Granitgestein unter umweltrelevanten Bedingungen untersucht. Bei Zugabe von im Grundwasser stabilen Bentonitkolloiden – Bentonit wird als ein geeignetes Verschlussmaterial für nukleare Abfälle erforscht – konnte ein erhöhter Transport des Pu(IV) beobachtet werden, der durch Sorption des Pu an die mobilen Kolloide hervorgerufen wird. Zur Speziation von Plutonium im Ultraspurenbereich wurde im Rahmen dieser Arbeit an der Entwicklung der Kopplung der CE mit der sehr sensitiven RIMS gearbeitet. Das Prinzip der offline-Kopplung basiert auf dem Sammeln der zu unterschiedlichen Zeiten am Ende der Kapillare eluierten Oxidationsstufen in einzelnen Fraktionen. Aus jeder Fraktion wird ein eigenes Filament hergestellt und mit RIMS auf seinen Plutoniumgehalt untersucht. Eine erste Validierung der Methode konnte durch Bestimmung der Oxidationsstufenzusammensetzung eines bekannten Gemischs erfolgreich für einen Gehalt von ca. 6*10^9 Atome Pu-239 durchgeführt werden. Dies stellt einen möglichen Zugang zu dem erwarteten Konzentrationsbereich im Fernfeld eines Endlagers dar.
Resumo:
Within this PhD thesis several methods were developed and validated which can find applicationare suitable for environmental sample and material science and should be applicable for monitoring of particular radionuclides and the analysis of the chemical composition of construction materials in the frame of ESS project. The study demonstrated that ICP-MS is a powerful analytical technique for ultrasensitive determination of 129I, 90Sr and lanthanides in both artificial and environmental samples such as water and soil. In particular ICP-MS with collision cell allows measuring extremely low isotope ratios of iodine. It was demonstrated that isotope ratios of 129I/127I as low as 10-7 can be measured with an accuracy and precision suitable for distinguishing sample origins. ICP-MS with collision cell, in particular in combination with cool plasma conditions, reduces the influence of isobaric interferences on m/z = 90 and is therefore well-suited for 90Sr analysis in water samples. However, the applied ICP-CC-QMS in this work is limited for the measurement of 90Sr due to the tailing of 88Sr+ and in particular Daly detector noise. Hyphenation of capillary electrophoresis with ICP-MS was shown to resolve atomic ions of all lanthanides and polyatomic interferences. The elimination of polyatomic and isobaric ICP-MS interferences was accomplished without compromising the sensitivity by the use of a high resolution mode as available on ICP-SFMS. Combination of laser ablation with ICP-MS allowed direct micro and local uranium isotope ratio measurements at the ultratrace concentrations on the surface of biological samples. In particular, the application of a cooled laser ablation chamber improves the precision and accuracy of uranium isotopic ratios measurements in comparison to the non-cooled laser ablation chamber by up to one order of magnitude. In order to reduce the quantification problem, a mono gas on-line solution-based calibration was built based on the insertion of a microflow nebulizer DS-5 directly into the laser ablation chamber. A micro local method to determine the lateral element distribution on NiCrAlY-based alloy and coating after oxidation in air was tested and validated. Calibration procedures involving external calibration, quantification by relative sensitivity coefficients (RSCs) and solution-based calibration were investigated. The analytical method was validated by comparison of the LA-ICP-MS results with data acquired by EDX.
Resumo:
Plutonium represents the major contribution to the radiotoxicity of spent nuclear fuel over storage times of up to several hundred thousand years. The speciation of plutonium in aquifer systems is important in order to assess the risks of high-level nuclear waste disposal and to acquire a deep knowledge of the mobilization and immobilization behavior of plutonium. In aqueous solutions, plutonium can coexist in four oxidation states and each one of them has different chemical and physical behavior. Tetravalent plutonium is the most abundant under natural conditions. Therefore, detailed speciation studies of tetravalent plutonium in contact with humic substances (HS) and kaolinite as a model clay mineral have been performed in this work. Plutonium is present in the environment at an ultratrace level. Therefore, speciation of Pu at the ultratrace level is mandatory. Capillary electrophoresis (CE) coupled to resonance ionization mass spectrometry (RIMS) was used as a new speciation method. CE-RIMS enables to improve the detection limit for plutonium species by 2 to 3 orders of magnitude compared to the previously developed CE-ICP-MS. For understanding the behavior of Pu(IV) in aqueous systems, redox reactions, complexation, and sorption behavior of plutonium were studied. The redox behavior of plutonium in contact with humic acid (HA) and fulvic acid (FA) was investigated. A relatively fast reduction of Pu(VI) in contact with HS was observed. It was mainly reduced to Pu(IV) and Pu(III) within a couple of weeks. The time dependence of the Pu(IV) complexation with Aldrich HA was investigated and a complex constant (logßLC) between 6.4 - 8.4 of Pu(IV) was determined by means of ultrafiltration taking into account the loading capacity (LC). The sorption of tetravalent plutonium onto kaolinite was investigated as a function of pH in batch experiments under aerobic and anaerobic conditions. The sorption edge was found at about pH = 1 and a maximum sorption at around pH = 8.5. In the presence of CO2 at pH > 8.5, the sorption of plutonium was decreased probably due to the formation of soluble carbonate complexes. For comparison, the sorption of Th(IV) onto kaolinite was also investigated and consistent results were found. The Pu(IV) sorption onto kaolinite was studied by XANES and EXAFS at pH 1, 4, 9 and the sorbed species on kaolinite surface was Pu(IV). Depending on the pH, only 1 - 10 % of the sorbed plutonium is desorbed from kaolinite and released into a fresh solution at the same pH value. Furthermore, the sorption of HS onto kaolinite was studied as a function of pH at varying concentrations of HS, as a prerequisite to understand the more complex ternary system. The sorption of HA onto kaolinite was found to be higher than that of FA. The investigation of the ternary systems (plutonium-kaolinite-humic substances) is performed as a function of pH, concentration of HS, and the sequences of adding the reactants. The presence of HS strongly influences the sorption of Pu(IV) onto kaolinite over the entire pH range. For comparison, the influence of HS on the sorption of Th(IV) onto kaolinite was also investigated and a good agreement with the results of Pu(IV) was obtained.
Resumo:
Die Elementmassenspektrometrie wurde in den letzten Jahren sehr erfolgreich zur Aufklärung verschiedener Fragestellungen in der Bioanalytik eingesetzt. Hierbei spielen vor allem Kopplungstechniken von Trennmethoden wie der Flüssigchromatographie (LC) oder der Kapillarelektrophorese (CE) mit der induktiv gekoppelten Plasma-Massenspektrometrie (ICP-MS) als Multielementdetektor mit hervorragenden Quantifizierungseigenschaften eine entscheidende Rolle bei der Untersuchung von Biopolymeren und deren Wechselwirkung mit verschiedenen Metallen. So wurden beispielsweise verschiedene Methoden für die Trennung und Detektion von Metalloproteinen oder DNA-Metall-Addukten in unterschiedlichen Probenmaterialien entwickelt. Die traditionelle und leistungsstärkste Trennmethode für Biopolymere aller Art, die Gelelektrophorese, wurde jedoch bislang nicht in einem Online-Verfahren an die ICP-MS gekoppelt, um solche Fragestellungen zu bearbeiten. Verschiedene Versuche auf der Basis der Laserablation wurden in diese Richtung unternommen, wobei diese Techniken als sehr umständlich und zeitaufwändig anzusehen sind. In dieser Arbeit wird erstmals die technische Realisierung einer Online-Kopplung der Gelelektrophorese mit der ICP-MS beschrieben. Das System basiert auf einem Prinzip aus der präparativen Gelelektrophorese, in welcher eine kontinuierliche Elution der getrennten Komponenten aus dem Gel während der laufenden Elektrophorese durchgeführt wird. Die eluierten Komponenten werden mit dem Elutionspuffer direkt in das Zerstäubersystem des ICP-MS geführt. Die ersten Untersuchungen wurden am Beispiel der Fragemente von doppelsträngiger DNA (dsDNA) durchgeführt. Kommerziell erhältliche Standardlösungen wurden mit der Online-GE-ICP-MS mittels Detektion von 31P an einem hochauflösenden Massenspektrometer mit einer Massenauflösung von 4000 analysiert. Die Trennbedingungen (z.B. pH-Wert oder Ionenstärke der Pufferlösungen) wurden für die Trennung von dsDNA-Fragementen in Agarosegelen optimiert und auf verschiedene dsDNA-Fragmente angewandt. In einem nächsten Schritt wurden die Quantifizierungsmöglichkeiten für Biopolymere untersucht. Sehr kleine Mengen an dsDNA konnten mit einer Präzision von weniger als 3% quantifiziert werden. Hierfür kamen verschiedene Möglichkeiten der externen Kalibration zum Einsatz, wie der Kalibration mit einem Phosphat-Standard oder einem kommerziell erhältlichen quantitativen dsDNA-Standard. Um das Potenzial der entwickelten Methode für die Untersuchung von Biopolymer-Metall-Wechselwirkungen zu demonstrieren, wurden Oligonukleotide mit Cisplatin unter physiologischen Bedingungen inkubiert und die Reaktionsprodukte mit der Online-GE-ICP-MS mittels 31P- und 195Pt-Detektion untersucht. Verschiedene Cisplatin-Oligonukleotid-Addukte konnten auf diese Weise beobachtet werden, was zur Identifizierung die Anwendung der MALDI-TOF-MS als komplementärer Form der Massenspektrometrie notwendig machte. Abschließend wurde die Isotopenverdünnungsanalyse zum Zweck der Quantifizierung herangezogen.
Resumo:
In der vorliegenden Arbeit wurde der Nachweis des Isotops Np-237 mit Resonanzionisations-Massenspektrometrie (RIMS) entwickelt und optimiert. Bei RIMS werden Probenatome mehrstufig-resonant mit Laserstrahlung angeregt, ionisiert und anschließend massenspektrometrisch nachgewiesen. Die Bestimmung geeigneter Energiezustände für die Anregung und Ionisation von Np-237 erfolgte durch Resonanzionisationsspektroskopie (RIS), wobei über 300 bisher unbekannte Energieniveaus und autoionisierende Zustände von Np-237 identifiziert wurden. Mit in-source-RIMS wird für das Isotop eine Nachweisgrenze von 9E+5 Atome erreicht. rnrnDie Mobilität von Np in der Umwelt hängt stark von seiner Elementspeziation ab. Für Sicherheitsanalysen potentieller Endlagerstandorte werden daher Methoden benötigt, die Aussagen über die unter verschiedenen Bedingungen vorliegenden Neptuniumspezies ermöglichen. Hierzu wurde eine online-Kopplung aus Kapillarelektrophorese (CE) und ICP-MS (inductively coupled plasma mass spectrometry) genutzt, mit der die Np-Redoxspezies Np(IV) und Np(V) noch bei einer Konzentrationen von 1E-9 mol/L selektiv nachgewiesen werden können. Das Verfahren wurde eingesetzt, um die Wechselwirkung des Elements mit Opalinuston unter verschiedenen Bedingungen zu untersuchen. Dabei konnte gezeigt werden, dass bei Gegenwart von Fe(II) Np(V) zu Np(IV) reduziert wird und dieses am Tongestein sorbiert. Dies führt insgesamt zu einer deutlich erhöhten Sorption des Np am Ton.
Resumo:
Die Dissertationsschrift beschäftigt sich mit der Entwicklung und Anwendung einer alternativen Probenzuführungstechnik für flüssige Proben in der Massenspektrometrie. Obwohl bereits einige Anstrengungen zur Verbesserung unternommen wurden, weisen konventionelle pneumatische Zerstäuber- und Sprühkammersysteme, die in der Elementspurenanalytik mittels induktiv gekoppeltem Plasma (ICP) standardmäßig verwendet werden, eine geringe Gesamteffizienz auf. Pneumatisch erzeugtes Aerosol ist durch eine breite Tropfengrößenverteilung gekennzeichnet, was den Einsatz einer Sprühkammer bedingt, um die Aerosolcharakteristik an die Betriebsbedingungen des ICPs anzupassen.. Die Erzeugung von Tropfen mit einer sehr engen Tropfengrößenverteilung oder sogar monodispersen Tropfen könnte die Effizienz des Probeneintrags verbessern. Ein Ziel dieser Arbeit ist daher, Tropfen, die mittels des thermischen Tintenstrahldruckverfahrens erzeugt werden, zum Probeneintrag in der Elementmassenspektrometrie einzusetzen. Das thermische Tintenstrahldruckverfahren konnte in der analytischen Chemie im Bereich der Oberflächenanalytik mittels TXRF oder Laserablation bisher zur gezielten, reproduzierbaren Deposition von Tropfen auf Oberflächen eingesetzt werden. Um eine kontinuierliche Tropfenerzeugung zu ermöglichen, wurde ein elektronischer Mikrokontroller entwickelt, der eine Dosiereinheit unabhängig von der Hard- und Software des Druckers steuern kann. Dabei sind alle zur Tropfenerzeugung relevanten Parameter (Frequenz, Heizpulsenergie) unabhängig voneinander einstellbar. Die Dosiereinheit, der "drop-on-demand" Aerosolgenerator (DOD), wurde auf eine Aerosoltransportkammer montiert, welche die erzeugten Tropfen in die Ionisationsquelle befördert. Im Bereich der anorganischen Spurenanalytik konnten durch die Kombination des DOD mit einem automatischen Probengeber 53 Elemente untersucht und die erzielbare Empfindlichkeiten sowie exemplarisch für 15 Elemente die Nachweisgrenzen und die Untergrundäquivalentkonzentrationen ermittelt werden. Damit die Vorteile komfortabel genutzt werden können, wurde eine Kopplung des DOD-Systems mit der miniaturisierten Fließinjektionsanalyse (FIA) sowie miniaturisierten Trenntechniken wie der µHPLC entwickelt. Die Fließinjektionsmethode wurde mit einem zertifizierten Referenzmaterial validiert, wobei für Vanadium und Cadmium die zertifizierten Werte gut reproduziert werden konnten. Transiente Signale konnten bei der Kopplung des Dosiersystems in Verbindung mit der ICP-MS an eine µHPLC abgebildet werden. Die Modifikation der Dosiereinheit zum Ankoppeln an einen kontinuierlichen Probenfluss bedarf noch einer weiteren Reduzierung des verbleibenden Totvolumens. Dazu ist die Unabhängigkeit von den bisher verwendeten, kommerziell erhältlichen Druckerpatronen anzustreben, indem die Dosiereinheit selbst gefertigt wird. Die Vielseitigkeit des Dosiersystems wurde mit der Kopplung an eine kürzlich neu entwickelte Atmosphärendruck-Ionisationsmethode, die "flowing atmospheric-pressure afterglow" Desorptions/Ionisations Ionenquelle (FAPA), aufgezeigt. Ein direkter Eintrag von flüssigen Proben in diese Quelle war bislang nicht möglich, es konnte lediglich eine Desorption von eingetrockneten Rückständen oder direkt von der Flüssigkeitsoberfläche erfolgen. Die Präzision der Analyse ist dabei durch die variable Probenposition eingeschränkt. Mit dem Einsatz des DOD-Systems können flüssige Proben nun direkt in die FAPA eingetragen, was ebenfalls das Kalibrieren bei quantitativen Analysen organischer Verbindungen ermöglicht. Neben illegalen Drogen und deren Metaboliten konnten auch frei verkäufliche Medikamente und ein Sprengstoffanalogon in entsprechend präpariertem reinem Lösungsmittel nachgewiesen werden. Ebenso gelang dies in Urinproben, die mit Drogen und Drogenmetaboliten versetzt wurden. Dabei ist hervorzuheben, dass keinerlei Probenvorbereitung notwendig war und zur Ermittlung der NWG der einzelnen Spezies keine interne oder isotopenmarkierte Standards verwendet wurden. Dennoch sind die ermittelten NWG deutlich niedriger, als die mit der bisherigen Prozedur zur Analyse flüssiger Proben erreichbaren. Um im Vergleich zu der bisher verwendeten "pin-to-plate" Geometrie der FAPA die Lösungsmittelverdampfung zu beschleunigen, wurde eine alternative Elektrodenanordnung entwickelt, bei der die Probe länger in Kontakt mit der "afterglow"-Zone steht. Diese Glimmentladungsquelle ist ringförmig und erlaubt einen Probeneintrag mittels eines zentralen Gasflusses. Wegen der ringförmigen Entladung wird der Name "halo-FAPA" (h-FAPA) für diese Entladungsgeometrie verwendet. Eine grundlegende physikalische und spektroskopische Charakterisierung zeigte, dass es sich tatsächlich um eine FAPA Desorptions/Ionisationsquelle handelt.
Resumo:
Addressing current limitations of state-of-the-art instrumentation in aerosol research, the aim of this work was to explore and assess the applicability of a novel soft ionization technique, namely flowing atmospheric-pressure afterglow (FAPA), for the mass spectrometric analysis of airborne particulate organic matter. Among other soft ionization methods, the FAPA ionization technique was developed in the last decade during the advent of ambient desorption/ionization mass spectrometry (ADI–MS). Based on a helium glow discharge plasma at atmospheric-pressure, excited helium species and primary reagent ions are generated which exit the discharge region through a capillary electrode, forming the so-called afterglow region where desorption and ionization of the analytes occurs. Commonly, fragmentation of the analytes during ionization is reported to occur only to a minimum extent, predominantly resulting in the formation of quasimolecular ions, i.e. [M+H]+ and [M–H]– in the positive and the negative ion mode, respectively. Thus, identification and detection of signals and their corresponding compounds is facilitated in the acquired mass spectra. The focus of the first part of this study lies on the application, characterization and assessment of FAPA–MS in the offline mode, i.e. desorption and ionization of the analytes from surfaces. Experiments in both positive and negative ion mode revealed ionization patterns for a variety of compound classes comprising alkanes, alcohols, aldehydes, ketones, carboxylic acids, organic peroxides, and alkaloids. Besides the always emphasized detection of quasimolecular ions, a broad range of signals for adducts and losses was found. Additionally, the capabilities and limitations of the technique were studied in three proof-of-principle applications. In general, the method showed to be best suited for polar analytes with high volatilities and low molecular weights, ideally containing nitrogen- and/or oxygen functionalities. However, for compounds with low vapor pressures, containing long carbon chains and/or high molecular weights, desorption and ionization is in direct competition with oxidation of the analytes, leading to the formation of adducts and oxidation products which impede a clear signal assignment in the acquired mass spectra. Nonetheless, FAPA–MS showed to be capable of detecting and identifying common limonene oxidation products in secondary OA (SOA) particles on a filter sample and, thus, is considered a suitable method for offline analysis of OA particles. In the second as well as the subsequent parts, FAPA–MS was applied online, i.e. for real time analysis of OA particles suspended in air. Therefore, the acronym AeroFAPA–MS (i.e. Aerosol FAPA–MS) was chosen to refer to this method. After optimization and characterization, the method was used to measure a range of model compounds and to evaluate typical ionization patterns in the positive and the negative ion mode. In addition, results from laboratory studies as well as from a field campaign in Central Europe (F–BEACh 2014) are presented and discussed. During the F–BEACh campaign AeroFAPA–MS was used in combination with complementary MS techniques, giving a comprehensive characterization of the sampled OA particles. For example, several common SOA marker compounds were identified in real time by MSn experiments, indicating that photochemically aged SOA particles were present during the campaign period. Moreover, AeroFAPA–MS was capable of detecting highly oxidized sulfur-containing compounds in the particle phase, presenting the first real-time measurements of this compound class. Further comparisons with data from other aerosol and gas-phase measurements suggest that both particulate sulfate as well as highly oxidized peroxyradicals in the gas phase might play a role during formation of these species. Besides applying AeroFAPA–MS for the analysis of aerosol particles, desorption processes of particles in the afterglow region were investigated in order to gain a more detailed understanding of the method. While during the previous measurements aerosol particles were pre-evaporated prior to AeroFAPA–MS analysis, in this part no external heat source was applied. Particle size distribution measurements before and after the AeroFAPA source revealed that only an interfacial layer of OA particles is desorbed and, thus, chemically characterized. For particles with initial diameters of 112 nm, desorption radii of 2.5–36.6 nm were found at discharge currents of 15–55 mA from these measurements. In addition, the method was applied for the analysis of laboratory-generated core-shell particles in a proof-of-principle study. As expected, predominantly compounds residing in the shell of the particles were desorbed and ionized with increasing probing depths, suggesting that AeroFAPA–MS might represent a promising technique for depth profiling of OA particles in future studies.