5 resultados para heart right ventricle double outlet
em AMS Tesi di Dottorato - Alm@DL - Università di Bologna
Resumo:
The objective of this study was to evaluate right ventricular function in patients with right ventricular volume overload in patients with (tetralogy of Fallot, and pulmonary atresia + VSD ) underwent corrective surgery; with echocardiography measure that can be easily applied; and to study the relationship between ProBNP and the contractile function of the right ventricle, dilated right atrium, and the consequences of pulmonary insufficiency . Methods: The study included 50 patients (50% males, mean age 30.64 ± 13.30 years) with prior cardiac surgical intervention of TDF (90%) or pulmonary atresia + VSD (10%). (49 pz) have performed a cardiac MRI and clinical evaluation, (47 pz) echocardiogram, (48 pz) ECG, (34 pz) a cardiopulmonary exercise testing, (29 pz) a dosage of ProBNP. Results: The S-wave velocity (p <0.0001), the TAPSE (p <0.0001) correlated significantly with RVEF estimated by cardiac MRI. The VO2 max was 27.93 ± 12.91 ml / kg / min, 15% of patients had VE/VCO2 The peak> 35. ProBNP correlated positively and significantly with the area of the right atrium (p = 0.0001), and negative and significant with VO2 max (p = 0.04). Those who have increased pulmonary insufficiency (PVR fraction> 30%) have a significantly increased RVED volume (p = 0.01), reduced VO2 max (p = 0.04), and lower ejection fraction of LV (p = 0.02) than the group of patients with PVR ≤ 30. Conclusion: The TAPSE and S-wave velocity are fundamental and may become the technique of choice for routine assessment of RV systolic function in adult patients with TOF. The monitoring of the Pro BNP is probably a choice, given the simplicity and their information that correlate with the test cardiopulmonary. In view of the ventricular-ventricular interaction, so measures to maintain or restore the functioning of the pulmonary valve could preserve biventricular function.
Resumo:
This work is structured as follows: In Section 1 we discuss the clinical problem of heart failure. In particular, we present the phenomenon known as ventricular mechanical dyssynchrony: its impact on cardiac function, the therapy for its treatment and the methods for its quantification. Specifically, we describe the conductance catheter and its use for the measurement of dyssynchrony. At the end of the Section 1, we propose a new set of indexes to quantify the dyssynchrony that are studied and validated thereafter. In Section 2 we describe the studies carried out in this work: we report the experimental protocols, we present and discuss the results obtained. Finally, we report the overall conclusions drawn from this work and we try to envisage future works and possible clinical applications of our results. Ancillary studies that were carried out during this work mainly to investigate several aspects of cardiac resynchronization therapy (CRT) are mentioned in Appendix. -------- Ventricular mechanical dyssynchrony plays a regulating role already in normal physiology but is especially important in pathological conditions, such as hypertrophy, ischemia, infarction, or heart failure (Chapter 1,2.). Several prospective randomized controlled trials supported the clinical efficacy and safety of cardiac resynchronization therapy (CRT) in patients with moderate or severe heart failure and ventricular dyssynchrony. CRT resynchronizes ventricular contraction by simultaneous pacing of both left and right ventricle (biventricular pacing) (Chapter 1.). Currently, the conductance catheter method has been used extensively to assess global systolic and diastolic ventricular function and, more recently, the ability of this instrument to pick-up multiple segmental volume signals has been used to quantify mechanical ventricular dyssynchrony. Specifically, novel indexes based on volume signals acquired with the conductance catheter were introduced to quantify dyssynchrony (Chapter 3,4.). Present work was aimed to describe the characteristics of the conductancevolume signals, to investigate the performance of the indexes of ventricular dyssynchrony described in literature and to introduce and validate improved dyssynchrony indexes. Morevoer, using the conductance catheter method and the new indexes, the clinical problem of the ventricular pacing site optimization was addressed and the measurement protocol to adopt for hemodynamic tests on cardiac pacing was investigated. In accordance to the aims of the work, in addition to the classical time-domain parameters, a new set of indexes has been extracted, based on coherent averaging procedure and on spectral and cross-spectral analysis (Chapter 4.). Our analyses were carried out on patients with indications for electrophysiologic study or device implantation (Chapter 5.). For the first time, besides patients with heart failure, indexes of mechanical dyssynchrony based on conductance catheter were extracted and studied in a population of patients with preserved ventricular function, providing information on the normal range of such a kind of values. By performing a frequency domain analysis and by applying an optimized coherent averaging procedure (Chapter 6.a.), we were able to describe some characteristics of the conductance-volume signals (Chapter 6.b.). We unmasked the presence of considerable beat-to-beat variations in dyssynchrony that seemed more frequent in patients with ventricular dysfunction and to play a role in discriminating patients. These non-recurrent mechanical ventricular non-uniformities are probably the expression of the substantial beat-to-beat hemodynamic variations, often associated with heart failure and due to cardiopulmonary interaction and conduction disturbances. We investigated how the coherent averaging procedure may affect or refine the conductance based indexes; in addition, we proposed and tested a new set of indexes which quantify the non-periodic components of the volume signals. Using the new set of indexes we studied the acute effects of the CRT and the right ventricular pacing, in patients with heart failure and patients with preserved ventricular function. In the overall population we observed a correlation between the hemodynamic changes induced by the pacing and the indexes of dyssynchrony, and this may have practical implications for hemodynamic-guided device implantation. The optimal ventricular pacing site for patients with conventional indications for pacing remains controversial. The majority of them do not meet current clinical indications for CRT pacing. Thus, we carried out an analysis to compare the impact of several ventricular pacing sites on global and regional ventricular function and dyssynchrony (Chapter 6.c.). We observed that right ventricular pacing worsens cardiac function in patients with and without ventricular dysfunction unless the pacing site is optimized. CRT preserves left ventricular function in patients with normal ejection fraction and improves function in patients with poor ejection fraction despite no clinical indication for CRT. Moreover, the analysis of the results obtained using new indexes of regional dyssynchrony, suggests that pacing site may influence overall global ventricular function depending on its relative effects on regional function and synchrony. Another clinical problem that has been investigated in this work is the optimal right ventricular lead location for CRT (Chapter 6.d.). Similarly to the previous analysis, using novel parameters describing local synchrony and efficiency, we tested the hypothesis and we demonstrated that biventricular pacing with alternative right ventricular pacing sites produces acute improvement of ventricular systolic function and improves mechanical synchrony when compared to standard right ventricular pacing. Although no specific right ventricular location was shown to be superior during CRT, the right ventricular pacing site that produced the optimal acute hemodynamic response varied between patients. Acute hemodynamic effects of cardiac pacing are conventionally evaluated after stabilization episodes. The applied duration of stabilization periods in most cardiac pacing studies varied considerably. With an ad hoc protocol (Chapter 6.e.) and indexes of mechanical dyssynchrony derived by conductance catheter we demonstrated that the usage of stabilization periods during evaluation of cardiac pacing may mask early changes in systolic and diastolic intra-ventricular dyssynchrony. In fact, at the onset of ventricular pacing, the main dyssynchrony and ventricular performance changes occur within a 10s time span, initiated by the changes in ventricular mechanical dyssynchrony induced by aberrant conduction and followed by a partial or even complete recovery. It was already demonstrated in normal animals that ventricular mechanical dyssynchrony may act as a physiologic modulator of cardiac performance together with heart rate, contractile state, preload and afterload. The present observation, which shows the compensatory mechanism of mechanical dyssynchrony, suggests that ventricular dyssynchrony may be regarded as an intrinsic cardiac property, with baseline dyssynchrony at increased level in heart failure patients. To make available an independent system for cardiac output estimation, in order to confirm the results obtained with conductance volume method, we developed and validated a novel technique to apply the Modelflow method (a method that derives an aortic flow waveform from arterial pressure by simulation of a non-linear three-element aortic input impedance model, Wesseling et al. 1993) to the left ventricular pressure signal, instead of the arterial pressure used in the classical approach (Chapter 7.). The results confirmed that in patients without valve abnormalities, undergoing conductance catheter evaluations, the continuous monitoring of cardiac output using the intra-ventricular pressure signal is reliable. Thus, cardiac output can be monitored quantitatively and continuously with a simple and low-cost method. During this work, additional studies were carried out to investigate several areas of uncertainty of CRT. The results of these studies are briefly presented in Appendix: the long-term survival in patients treated with CRT in clinical practice, the effects of CRT in patients with mild symptoms of heart failure and in very old patients, the limited thoracotomy as a second choice alternative to transvenous implant for CRT delivery, the evolution and prognostic significance of diastolic filling pattern in CRT, the selection of candidates to CRT with echocardiographic criteria and the prediction of response to the therapy.
Resumo:
Scopo dello studio: la cardiomiopatia aritmogena (CA) è conosciuta come causa di morte improvvisa, la sua relazione con lo scompenso cardiaco (SC) è stata scarsamente indagata. Scopo dello studio è la definizione della prevalenza e incidenza dello SC, nonché della fisiopatologia e delle basi morfologiche che conducono i pazienti con CA a SC e trapianto di cuore. Metodi: abbiamo analizzato retrospettivamente 64 pazienti con diagnosi di CA e confrontato i dati clinici e strumentali dei pazienti con e senza SC (NYHA III-IV). Abbiamo analizzato i cuori espiantati dei pazienti sottoposti a trapianto presso i centri di Bologna e Padova. Risultati: la prevalenza dello SC alla prima osservazione era del 14% e l’incidenza del 2,3% anno-persona. Sedici pazienti (23%) sono stati sottoposti a trapianto. I pazienti con SC erano più giovani all’esordio dei sintomi (46±16 versus 37±12 anni, p=0.04); il ventricolo destro (VD) era più dilatato e ipocinetico all’ecocardiogramma (RVOT 41±6 versus 37±7 mm, p=0.03; diametro telediastolico VD 38±11 versus 28±8 mm, p=0.0001; frazione di accorciamento 23%±7 versus 32%±11, p= 0.002). Il ventricolo sinistro (VS) era lievemente più dilatato (75±29 ml/m2 versus 60±19, p= 0.0017) e globalmente più ipocinetico (frazione di eiezione = 35%±14 versus 57%±12, p= 0.001). Il profilo emodinamico dei pazienti sottoposti a trapianto era caratterizzato da un basso indice cardiaco (1.8±0.2 l/min/m2) con pressione capillare e polmonare tendenzialmente normale (12±8 mmHg e 26±10 mmHg). L’analisi dettagliata dei 36 cuori dei pazienti trapiantati ha mostrato sostituzione fibro-adiposa transmurale nel VD e aree di fibrosi nel VS. Conclusioni: Nella CA lo SC può essere l’unico sintomo alla presentazione e condurre a trapianto un rilevante sottogruppo di pazienti. Chi sviluppa SC è più giovane, ha un interessamento del VD più severo accanto a un costante interessamento del VS, solo lievemente dilatato e ipocinetico, con sostituzione prevalentemente fibrosa.
Resumo:
In questo lavoro ci siamo posti come obiettivo lo studio della disfunzione atrio-ventricolare mediante tecniche ecocardiografiche avanzate (come il Tissue Doppler Imaging - TDI) in cani affetti da malattia mitralica cronica (MVD). Una prima parte è volta alla valutazione della funzionalità diastolica del ventricolo destro. Ci siamo proposti di analizzare la funzione del ventricolo destro in cani affetti da malattia del cuore sinistro per comprendere se quest’ultima possa condizionare direttamente la performance del settore cardiaco controlaterale. I risultati più importanti che abbiamo riscontrato sono: l’assenza di differenze significative nella disfunzione sisto-diastolica del ventricolo destro in cani con MVD a diverso stadio; la diretta correlazione tra le variabili TDI di funzionalità del ventricolo destro con il grado di disfunzione del ventricolo sinistro, come indicatori di interdipendenza ventricolare; ed infine il riscontro di una maggior tendenza ad alterazioni diastoliche del ventricolo sinistro in cani con ipertensione polmonare. A quest’ultimo proposito, per quanto riguarda le variabili TDI, il rapporto E/e’ dell’anulus mitralico laterale e settale è risultato avere una differenza significativa tra i cani con ipertensione polmonare e quelli privi di ipertensione polmonare (P<0,01). Nel secondo studio abbiamo applicato il TDI per l’analisi della funzione sisto-diastolica dell’atrio sinistro. Il lavoro è stato articolato in una parte di validazione della metodica su cani normali ed una su animali affetti da MDV. I risultati ottenuti mostrano che la valutazione ecocardiografica delle proprietà di deformazione dell’atrio sinistro basata sul TDI è attuabile e riproducibile nel cane. Abbiamo fornito dei valori di normalità per questa specie e confrontato questi dati con quelli ricavati in cani portatori di MVD. Le differenza tra le varie classi di malattia, nei diversi gradi di dilatazione atriale, sono risultate limitate, ma abbiamo individuato delle correlazioni tra i parametri TDI ed alcune variabili di funzionalità atriale.
Resumo:
L'intervento di connessione cavo-polmonare totale (TCPC) nei pazienti portatori di cuore univentricolare, a causa della particolare condizione emodinamica, determina un risentimento a carico di numerosi parenchimi. Scopo della ricerca è di valutare l'entità di questo danno ad un follow-up medio-lungo. Sono stati arruolati 115 pazienti, sottoposti ad intervento presso i centri di Cardiochirurgia Pediatrica di Bologna (52 pz) e Torino (63 pz). Il follow-up medio è stato di 125±2 mesi. I pazienti sono stati sottoposti ad indagine emodinamica (88 pz), test cardiopolmonare (75 pz) e Fibroscan ed ecografia epatica (47 pz). La pressione polmonare media è stata di 11.5±2.6mmHg, ed in 12 pazienti i valori di pressione polmonare erano superiori a 15mmHg. La pressione atriale media era di 6.7±2.3mmHg ed il calcolo delle resistenze vascolari polmonari indicizzate (RVP) era in media di 2±0.99 UW/m2. In 29 pazienti le RVP erano superiori a 2 UW/m2. La VO2 max in media era pari a 28±31 ml/Kg/min, 58±15 % del valore teorico. La frequenza cardiaca massima all'apice dello sforzo era di 151±22 bpm, pari al 74±17% del valore teorico. Il Fibroscan ha fornito un valore medio di 17.01 kPa (8-34.3kPa). Cinque pazienti erano in classe F2, 9 pazienti in classe F3 e 33 pazienti risultavano in classe F4. Nei pazienti con follow-up maggiore di 10 anni il valore di stiffness epatica (19.6±5.2kPa) è risultato significativamente maggiore a quello dei pazienti con follow-up minore di 10 anni (15.1±5.8kPa, p<0.01). La frequenza cardiaca massima raggiunta durante lo sforzo del test cardiopolmonare è risultata significativamente correlata alla morfologia del ventricolo unico, risultando del 67.8±14.4% del valore teorico nei pazienti portatori di ventricolo destro contro il 79.6±8.7% dei portatori di ventricolo sinistro (p=0.006). L'intervento di TCPC determina un risentimento a carico di numerosi parenchimi proporzionale alla lunghezza del follow-up, e necessita pertanto un costante monitoraggio clinico-strumentale multidisciplinare.