7 resultados para Post-surgical neuropathic peripheral pain

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Treatment of spinal fracture and luxation in small animals Traumatic spinal injuries usually result from a mechanic trauma. Spinal facture and luxations generally occur in the junction between and more mobile parts of the spinal column: close to the skull, thorax and pelvis. Fractures may occur alone or in combination with luxation as fracture/luxation. When the fractures are not stable the best solution is the surgical fixation. Internal and external fixation are the surgical methods for the treatment of vertebral fractures and luxations. The authors report the treatment of 12 cases of thoracic and lumbar vertebral fractures and luxations in small animals using the screws/pins and Polymethylmethacrylate technique. The analysis of results is a contribute I the valutation of surgical technique and complications in the post-surgical period.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Il rachide è stato suddiviso in tre colonne da Denis: anteriore e centrale comprendono la metà anteriore del corpo vertebrale, la metà posteriore e l’inizio dei peduncoli, mentre la colonna posteriore comprende l’arco e i peduncoli stessi. In caso di resezione o lesione della colonna anteriore e media è indicata la ricostruzione. Diverse tecniche e materiali possono essere usati per ricostruire il corpo vertebrale. Innesti vascolarizzati, autograft, allograft sono stati usati, così come impianti sintetici di titanio o materiale plastico come il PEEK (Poly etere etere ketone). Tutti questi materiali hanno vantaggi e svantaggi in termini di proprietà intrinseche, resistenza meccanica, modulo di elasticità, possibilità di trasmissione malattie, capacità di fondersi con l’osso ospite o meno. Le soluzioni più usate sono le cage in titanio o carbonio, il PMMA ( Poli methil metacrilato), gli innesti ossei massivi. Si è effettuato uno studio di coorte retrospettivo paragonando due gruppi di pazienti oncologici spinali trattati da due chirurghi esperti in un centro di riferimento, con vertebrectomia e ricostruzione della colonna anteriore: un gruppo con cage in carbonio o titanio, l’altro gruppo con allograft massivo armato di innesto autoplastico o mesh in titanio. Si sono confrontati i risultati in termini di cifosi segmenterai evolutiva, fusione ossea e qualità di vita del paziente. Il gruppo delle cage in carbonio / titanio ha avuto risultati leggermente migliori dal punto di vista biomeccanico ma non statisticamente significativo, mentre dal punto di vista della qualità di vita i risultati sono stati migliori nel gruppo allograft. Non ci sono stati fallimenti meccanici della colonna anteriore in entrambi i gruppi, con un Fu tra 12 e 60 mesi. Si sono paragonati anche i costi delle due tecniche. In conclusione l’allogar è una tecnica sicura ed efficace, con proprietà meccaniche solide, soprattutto se armato con autograft o mesi in titanio.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Chronic pain affects one in five adults, reducing quality of life and increasing risk of developing co-morbidities such as depression. Neuropathic pain results by lesions to the nervous system that alter its structure and function leading to spontaneous pain and amplified responses to noxious and innocuous stimuli. The Opioid System is probably the most important system involved in control of nociceptive transmission. Dynorphin and nociceptin systems have been suggested key mediators of some neuropathic pain aspects. An important role also for BDNF has been recently suggested since its involvement in the peripheral and central sensitization phenomena is known. We studied neuroplastic alterations occurring in chronic pain in mice subjected to the chronic constriction injury (CCI). We investigated gene expression alterations of both BDNF and Opioid System at spinal level at different intervals of time. A transient upregulation of pBDNF and pDYN was observed in spinal cord, while increasing upregulation of ppN/OFQ was found in the DRGs of injured mice. Development of neuropathic behavioral signs has been observed in ICR/CD-1 and BDNF+/+ mice, subjected to CCI. A different development of these signs was observed in BDNF+/-. We also studied gene expression changes of investigated systems in different brain areas fourteen days after surgery. We found pBDNF, pDYN, pKOP, ppN/OFQ and pNOP gene expression alterations in several areas of CCI mice. In the same brain regions we also determined bioactive nociceptin peptide levels, and elevated N/OFQ levels were observed in the amygdala area. Histone modifications studies have been performed in BDNF and DYN gene promoters of CCI animal spinal cord showing selected alterations in pDYN gene promoter. In addition, a preliminary characterization of the innovative NOP-EGFP mice was performed. Overall, our results could be useful to understand which and how neuropeptidergic systems are involved in neuroplastic mechanism occurring in neuropathic pain.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction The “eversion” technique for carotid endarterectomy (e-CEA), that involves the transection of the internal carotid artery at the carotid bulb and its eversion over the atherosclerotic plaque, has been associated with an increased risk of postoperative hypertension possibly due to a direct iatrogenic damage to the carotid sinus fibers. The aim of this study is to assess the long-term effect of the e-CEA on arterial baroreflex and peripheral chemoreflex function in humans. Methods A retrospective review was conducted on a prospectively compiled computerized database of 3128 CEAs performed on 2617 patients at our Center between January 2001 and March 2006. During this period, a total of 292 patients who had bilateral carotid stenosis ≥70% at the time of the first admission underwent staged bilateral CEAs. Of these, 93 patients had staged bilateral e-CEAs, 126 staged bilateral s- CEAs and 73 had different procedures on each carotid. CEAs were performed with either the eversion or the standard technique with routine Dacron patching in all cases. The study inclusion criteria were bilateral CEA with the same technique on both sides and an uneventful postoperative course after both procedures. We decided to enroll patients submitted to bilateral e-CEA to eliminate the background noise from contralateral carotid sinus fibers. Exclusion criteria were: age >70 years, diabetes mellitus, chronic pulmonary disease, symptomatic ischemic cardiac disease or medical therapy with b-blockers, cardiac arrhythmia, permanent neurologic deficits or an abnormal preoperative cerebral CT scan, carotid restenosis and previous neck or chest surgery or irradiation. Young and aged-matched healthy subjects were also recruited as controls. Patients were assessed by the 4 standard cardiovascular reflex tests, including Lying-to-standing, Orthostatic hypotension, Deep breathing, and Valsalva Maneuver. Indirect autonomic parameters were assessed with a non-invasive approach based on spectral analysis of EKG RR interval, systolic arterial pressure, and respiration variability, performed with an ad hoc software. From the analysis of these parameters the software provides the estimates of spontaneous baroreflex sensitivity (BRS). The ventilatory response to hypoxia was assessed in patients and controls by means of classic rebreathing tests. Results A total of 29 patients (16 males, age 62.4±8.0 years) were enrolled. Overall, 13 patients had undergone bilateral e-CEA (44.8%) and 16 bilateral s-CEA (55.2%) with a mean interval between the procedures of 62±56 days. No patient showed signs or symptoms of autonomic dysfunction, including labile hypertension, tachycardia, palpitations, headache, inappropriate diaphoresis, pallor or flushing. The results of standard cardiovascular autonomic tests showed no evidence of autonomic dysfunction in any of the enrolled patients. At spectral analysis, a residual baroreflex performance was shown in both patient groups, though reduced, as expected, compared to young controls. Notably, baroreflex function was better maintained in e-CEA, compared to standard CEA. (BRS at rest: young controls 19.93 ± 2.45 msec/mmHg; age-matched controls 7.75 ± 1.24; e-CEA 13.85 ± 5.14; s-CEA 4.93 ± 1.15; ANOVA P=0.001; BRS at stand: young controls 7.83 ± 0.66; age-matched controls 3.71 ± 0.35; e-CEA 7.04 ± 1.99; s-CEA 3.57 ± 1.20; ANOVA P=0.001). In all subjects ventilation (VÝ E) and oximetry data fitted a linear regression model with r values > 0.8. Oneway analysis of variance showed a significantly higher slope both for ΔVE/ΔSaO2 in controls compared with both patient groups which were not different from each other (-1.37 ± 0.33 compared with -0.33±0.08 and -0.29 ±0.13 l/min/%SaO2, p<0.05, Fig.). Similar results were observed for and ΔVE/ΔPetO2 (-0.20 ± 0.1 versus -0.01 ± 0.0 and -0.07 ± 0.02 l/min/mmHg, p<0.05). A regression model using treatment, age, baseline FiCO2 and minimum SaO2 achieved showed only treatment as a significant factor in explaining the variance in minute ventilation (R2= 25%). Conclusions Overall, we demonstrated that bilateral e-CEA does not imply a carotid sinus denervation. As a result of some expected degree of iatrogenic damage, such performance was lower than that of controls. Interestingly though, baroreflex performance appeared better maintained in e-CEA than in s-CEA. This may be related to the changes in the elastic properties of the carotid sinus vascular wall, as the patch is more rigid than the endarterectomized carotid wall that remains in the e-CEA. These data confirmed the safety of CEA irrespective of the surgical technique and have relevant clinical implication in the assessment of the frequent hemodynamic disturbances associated with carotid angioplasty stenting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In case of severe osteoarthritis at the knee causing pain, deformity, and loss of stability and mobility, the clinicians consider that the substitution of these surfaces by means of joint prostheses. The objectives to be pursued by this surgery are: complete pain elimination, restoration of the normal physiological mobility and joint stability, correction of all deformities and, thus, of limping. The knee surgical navigation systems have bee developed in computer-aided surgery in order to improve the surgical final outcome in total knee arthroplasty. These systems provide the surgeon with quantitative and real-time information about each surgical action, like bone cut executions and prosthesis component alignment, by mean of tracking tools rigidly fixed onto the femur and the tibia. Nevertheless, there is still a margin of error due to the incorrect surgical procedures and to the still limited number of kinematic information provided by the current systems. Particularly, patello-femoral joint kinematics is not considered in knee surgical navigation. It is also unclear and, thus, a source of misunderstanding, what the most appropriate methodology is to study the patellar motion. In addition, also the knee ligamentous apparatus is superficially considered in navigated total knee arthroplasty, without taking into account how their physiological behavior is altered by this surgery. The aim of the present research work was to provide new functional and biomechanical assessments for the improvement of the surgical navigation systems for joint replacement in the human lower limb. This was mainly realized by means of the identification and development of new techniques that allow a thorough comprehension of the functioning of the knee joint, with particular attention to the patello-femoral joint and to the main knee soft tissues. A knee surgical navigation system with active markers was used in all research activities presented in this research work. Particularly, preliminary test were performed in order to assess the system accuracy and the robustness of a number of navigation procedures. Four studies were performed in-vivo on patients requiring total knee arthroplasty and randomly implanted by means of traditional and navigated procedures in order to check for the real efficacy of the latter with respect to the former. In order to cope with assessment of patello-femoral joint kinematics in the intact and replaced knees, twenty in-vitro tests were performed by using a prototypal tracking tool also for the patella. In addition to standard anatomical and articular recommendations, original proposals for defining the patellar anatomical-based reference frame and for studying the patello-femoral joint kinematics were reported and used in these tests. These definitions were applied to two further in-vitro tests in which, for the first time, also the implant of patellar component insert was fully navigated. In addition, an original technique to analyze the main knee soft tissues by means of anatomical-based fiber mappings was also reported and used in the same tests. The preliminary instrumental tests revealed a system accuracy within the millimeter and a good inter- and intra-observer repeatability in defining all anatomical reference frames. In in-vivo studies, the general alignments of femoral and tibial prosthesis components and of the lower limb mechanical axis, as measured on radiographs, was more satisfactory, i.e. within ±3°, in those patient in which total knee arthroplasty was performed by navigated procedures. As for in-vitro tests, consistent patello-femoral joint kinematic patterns were observed over specimens throughout the knee flexion arc. Generally, the physiological intact knee patellar motion was not restored after the implant. This restoration was successfully achieved in the two further tests where all component implants, included the patellar insert, were fully navigated, i.e. by means of intra-operative assessment of also patellar component positioning and general tibio-femoral and patello-femoral joint assessment. The tests for assessing the behavior of the main knee ligaments revealed the complexity of the latter and the different functional roles played by the several sub-bundles compounding each ligament. Also in this case, total knee arthroplasty altered the physiological behavior of these knee soft tissues. These results reveal in-vitro the relevance and the feasibility of the applications of new techniques for accurate knee soft tissues monitoring, patellar tracking assessment and navigated patellar resurfacing intra-operatively in the contest of the most modern operative techniques. This present research work gives a contribution to the much controversial knowledge on the normal and replaced of knee kinematics by testing the reported new methodologies. The consistence of these results provides fundamental information for the comprehension and improvements of knee orthopedic treatments. In the future, the reported new techniques can be safely applied in-vivo and also adopted in other joint replacements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Il dolore non è solo una conseguenza della malattia ma un fattore patogeno che è di per se stesso in grado di perpetuare il danno all’organismo. Il suo trattamento non è quindi solo un atto di umanità ma un contributo ad arrestare la malattia e restituire la salute al paziente. Tra i farmaci più popolari per la terapia del dolore negli animali da affezione si trova la buprenorfina. Questa molecola viene impiegata con successo da anni nel cane e nel gatto per motivi riconducibili, oltre che alla sua efficacia (la sua potenza è diverse volte quella della morfina), alla lunga durata d’azione e alla scarsità degli effetti collaterali. Nonostante l’ampia diffusione e longevità del suo utilizzo, però, sappiamo poco della farmacocinetica di questa molecola negli animali da affezione; i dosaggi clinicamente impiegati sono di fatto estrapolati dagli studi nell’uomo oppure basati su semplici osservazioni degli effetti; i pochi dati farmacocinetici ottenuti nel cane fanno riferimento a singoli boli di dosi che non sempre corrispondono a quelle clinicamente impiegate. Nonostante la buprenorfina trovi il suo principale impiego nelle somministrazioni protratte a lungo (durante il periodo post-operatorio o la degenza ospedaliera) non è mai stato indagato il profilo farmacocinetico della molecola somministrata a boli ripetuti o come infusione continua. Il nostro studio si pone come obiettivo di indagare la farmacocinetica della buprenorfina somministrata come bolo di carico seguito da un’infusione costante a dosaggi considerati clinici in cani sani nel periodo post operatorio. Lo scopo ultimo è quello di sviluppare un protocollo per la somministrazione di questa molecola in modo prolungato in pazienti degenti ed addolorati per poi, in futuro, confrontare la somministrazione come infusione continua con i tradizionali boli ripetuti. Per lo studio sono state utilizzate giovani cagne adulte di taglia media o grande sottoposte ad intervento di ovariectomia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L’approccio chirurgico agli adenomi ipofisari ACTH secernenti è la terapia d’elezione nell’uomo. L’ipofisectomia transfenoidale è invece una tecnica poco diffusa in ambito veterinario. La terapia più diffusa nel cane con ipercortisolismo ipofisi dipendente (PDH) è di tipo medico e prevede la somministrazione di farmaci inibitori della sintesi del cortisolo. Gli adenomi ipofisari possono aumentare di volume e determinare una conseguente sintomatologia neurologica; in questi casi le uniche opzioni terapeutiche sono rappresentate dall’asportazione chirurgica della neoplasia e dalla radioterapia. Nella presente tesi vengono descritti 8 interventi di ipofisectomia transfenoidale effettuati su 7 cani con macroadenoma ipofisario presso il Dipartimento di Scienze Mediche Veterinarie dell’Università di Bologna. La difficoltà maggiore per il chirurgo è rappresentata dalla localizzazione della fossa ipofisaria rispetto ai punti di repere visibile in tomografia computerizzata o in risonanza magnetica nucleare, oltre ai problemi di sanguinamento durante la rimozione della neoplasia. Nel periodo post-operatorio maggiori complicazioni si riscontrano in soggetti con adenomi ipofisari di maggiori dimensioni. Al contrario, in presenza di adenomi di dimensioni più contenute, la ripresa post-operatoria risulta più rapida e il tasso di successo maggiore. Al fine di poter eseguire nel cane l’exeresi mirata della sola neoplasia ipofisaria, al pari di quanto avviene nell’uomo, è stato condotto uno studio sulla tomografia computerizzata (TC) in 86 cani con PDH. Il protocollo TC non ha tuttavia permesso di individuare con precisione la posizione della neoplasia per guidare il chirurgo nella sua rimozione. In due casi riportati nel presente lavoro si è verificata una recidiva della neoplasia ipofisaria. In un soggetto si è optato per il reintervento, mentre nell’altro caso per la radioterapia. Entrambe le opzioni hanno garantito una buona qualità di vita per più di un anno dall’intervento terapeutico. Questi casi clinici dimostrano come il reintervento e la radioterapia possano essere considerate valide opzioni in caso di recidiva.