99 resultados para Autonomous Loading Controller

em Reposit


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Robotic vehicle navigation in unstructured and uncertain environments is still a challenge. This paper presents the implementation of a multivalued neurofuzzy controller for autonomous ground vehicle (AGVs) in indoor environments. The control system consists of a hierarchy of mobile robot using multivalued adaptive neuro-fuzzy inference system behaviors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents some improvements regarding to the autonomous mobile robot Emmy based on Paraconsistent Annotated Evidential Logic ET. A discussion on navigation system is presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste estudo, foram investigadas as densidades de carga adequadas para transporte de matrinxãs juvenis em sistema fechado com sacos plásticos. O transporte de 4h foi feito com peixes (23,5±0,4g; 11,6 (0,08cm) em jejum por 24h, em densidades de 83g L-1 (D1), 125g L-1 (D2), 168g L-1 (D3) e 206g L-1 (D4). Os peixes foram amostrados antes do transporte (AT), logo após o transporte (chegada) (DT) e 24h depois. A qualidade da água foi monitorada antes da captura dos peixes nos tanques de depuração, após o transporte nos sacos plásticos e nos tanques de recuperação. O oxigênio da água diminuiu para valores inferiores a 4mg L-1 em D2, D3 e D4, a temperatura esteve em torno de 32°C, pH 6,5-6,78, a amônia total foi de 1,09-1,7mg L-1, a amônia não-ionizada foi de 3,58-9,33 x 10³mg L-1 e alcalinidade 134-165mg CaCO3 L-1. O cortisol plasmático e a glicose sanguínea aumentaram após o transporte nos peixes em todas as densidades ensaiadas, voltando aos valores controle 24h depois. Os valores de osmolaridade não mudaram logo após o transporte, mas aumentaram 24h depois de modo igual em todas as densidades. O cloreto plasmático diminuiu na chegada, de modo inversamente proporcional à densidade de carga. O hematócrito diminuiu 24h depois da chegada dos peixes, em todas as densidades testadas, mas não houve diferença no número de eritrócitos. Não houve mortalidade até uma semana após o transporte. O matrinxã mostrou ser uma espécie tolerante a altas densidades de carga em embalagens para transporte além de suportar baixos níveis de oxigênio na água.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Lyapunov-based stabilizing control design method for uncertain nonlinear dynamical systems using fuzzy models is proposed. The controller is constructed using a design model of the dynamical process to be controlled. The design model is obtained from the truth model using a fuzzy modeling approach. The truth model represents a detailed description of the process dynamics. The truth model is used in a simulation experiment to evaluate the performance of the controller design. A method for generating local models that constitute the design model is proposed. Sufficient conditions for stability and stabilizability of fuzzy models using fuzzy state-feedback controllers are given. The results obtained are illustrated with a numerical example involving a four-dimensional nonlinear model of a stick balancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The conventional Newton and fast decoupled power flow (FDPF) methods have been considered inadequate to obtain the maximum loading point of power systems due to ill-conditioning problems at and near this critical point. It is well known that the PV and Q-theta decoupling assumptions of the fast decoupled power flow formulation no longer hold in the vicinity of the critical point. Moreover, the Jacobian matrix of the Newton method becomes singular at this point. However, the maximum loading point can be efficiently computed through parameterization techniques of continuation methods. In this paper it is shown that by using either theta or V as a parameter, the new fast decoupled power flow versions (XB and BX) become adequate for the computation of the maximum loading point only with a few small modifications. The possible use of reactive power injection in a selected PV bus (Q(PV)) as continuation parameter (mu) for the computation of the maximum loading point is also shown. A trivial secant predictor, the modified zero-order polynomial which uses the current solution and a fixed increment in the parameter (V, theta, or mu) as an estimate for the next solution, is used in predictor step. These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained with the new approach for the IEEE test systems (14, 30, 57 and 118 buses) are presented and discussed in the companion paper. The results show that the characteristics of the conventional method are enhanced and the region of convergence around the singular solution is enlarged. In addition, it is shown that parameters can be switched during the tracing process in order to efficiently determine all the PV curve points with few iterations. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The parameterized fast decoupled power flow (PFDPF), versions XB and BX, using either theta or V as a parameter have been proposed by the authors in Part I of this paper. The use of reactive power injection of a selected PVbus (Q(PV)) as the continuation parameter for the computation of the maximum loading point (MLP) was also investigated. In this paper, the proposed versions obtained only with small modifications of the conventional one are used for the computation of the MLP of IEEE test systems (14, 30, 57 and 118 buses). These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained with the new approaches are presented and discussed. The results show that the characteristics of the conventional FDPF method are enhanced and the region of convergence around the singular solution is enlarged. In addition, it is shown that these versions can be switched during the tracing process in order to efficiently determine all the PV curve points with few iterations. A trivial secant predictor, the modified zero-order polynomial, which uses the current solution and a fixed increment in the parameter (V, theta, or mu) as an estimate for the next solution, is used for the predictor step. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This letter presents an alternative approach for reducing the total real power losses by using a continuation method. Results for two simple test systems and for the IEEE 57-bus system show that this procedure results in larger voltage stability margin. Besides, the reduction of real power losses obtained with this procedure leads to significant money savings and, simultaneously, to voltage profile improvement. Comparison between the solution of an optimal power flow and the proposed method shows that the latter can provide near optimal results and so, it can be a reasonable alternative to power system voltage stability enhancement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents the development of an IEEE 1451.2 protocol controller based on a low-cost FPGA that is directly connected to the parallel port of a conventional personal computer. In this manner it is possible to implement a Network Capable Application Processor (NCAP) based on a personal computer, without parallel port modifications. This approach allows supporting the ten signal lines of the 10-wire IEEE 1451.2 Transducer Independent Interface (TII), that connects the network processor to the Smart Transducer Interface Module (STIM) also defined in the IEEE 1451.2 standard. The protocol controller is connected to the STIM through the TII's physical interface, enabling the portability of the application at the transducer and network processor level. The protocol controller architecture was fully developed in VHDL language and we have projected a special prototype configured in a general-purpose programmable logic device. We have implemented two versions of the protocol controller, which is based on IEEE 1451 standard, and we have obtained results using simulation and experimental tests. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the use of differential evolution ( DE), a global search technique inspired by evolutionary theory, to find the parameters that are required to achieve optimum dynamic response of parallel operation of inverters with no interconnection among the controllers is proposed. Basically, in order to reach such a goal, the system is modeled in a certain way that the slopes of P-omega and Q-V curves are the parameters to be tuned. Such parameters, when properly tuned, result in system's eigenvalues located in positions that assure the system's stability and oscillation-free dynamic response with minimum settling time. This paper describes the modeling approach and provides an overview of the motivation for the optimization and a description of the DE technique. Simulation and experimental results are also presented, and they show the viability of the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to present the factors that influence planning for immediate loading of implants through a literature review for treatment success. Research was conducted in the PubMed database including the key words immediate implant loading, implant-supported prostheses, and implant planning for studies published from 2000 to 2011. Forty-eight articles were used in this review to describe the indications and counterindications, presurgical planning, and technologies available for planning of this treatment alternative.