91 resultados para validation study

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

70.00% 70.00%

Publicador:

Resumo:

STUDY OBJECTIVE: To validate hysteroscopic view with histology in cases of endometrial hyperplasia and cancer in patients with abnormal uterine bleeding (AUB)DESIGN: Retrospective study.(Canadian Task Force classification II-3).SETTING: University teaching hospitals in Rio de Janeiro and São Paulo, and private office in Rio de Janeiro.PATIENTS: Four thousand and fifty-four patients with AUB in whom hysteroscopic views were complete and the histologic result was conclusive.INTERVENTION: Four thousand and fifty-four office hysteroscopies with complete views and conclusive histologic results. The material for histologic examination was obtained through biopsy of the lesion in an outpatient unit or through the resection of the entire lesion in patients who underwent surgery. Histology was considered the gold standard and compared with the hysteroscopic view.MEASUREMENTS AND MAIN RESULTS: In the histology of the 4054 examinations, 613 (15.2%) were endometrial hyperplasia, and 105 (2.6%) were endometrial cancer. The most frequent hysteroscopic finding was endometrial polyps (31.2%). In endometrial hyperplasia, the sensitivity of the hysteroscopic view was 56.3% (95% CI 52.21-60.2%), specificity was 89.1% (95% CI 88.0%-90.1%), positive predictive value (PPV) was 48.0% (95% CI 44.3%-51.7%), negative predictive value (NPV) was 92.0% (95% Cl 90.1%-92.9%), and accuracy was 72.7% (95% CI 70.7%-74.7%). Accuracy was defined as the proportion of correct results among the hysteroscopic examinations. In endometrial cancer, the sensitivity of the hysteroscopic view was 80.0% (95% Cl 71.1%-87.2%), specificity was 99.5% (95% CI 99.2%-99.7%), PPV was 81.5% (95% Cl 72.7%-88.5%), NPV was 99.5% (95% CI 99.2%-99.7%), and accuracy was 89.8% (95% CI, 85.9%-93.6%). In the 814 patients (20.0%) in whom the hysteroscopic view was normal, there were no false negatives for endometrial cancer; however, there were 37 (4.5%) false negatives for endometrial hyperplasia. In the histologic cases of endometrial cancer, 101 (96.2%) hysteroscopic views were compatible with cancer or hyperplasia (80.0% and 16.2%, respectively). Ninety-seven out of 103 hysteroscopic views with cancer findings (94.2%) had histologic diagnosis of cancer or hyperplasia (81.5% and 12.6%, respectively).CONCLUSION: It seems that even in face of good validity of hysteroscopic view for endometrial hyperplasia and cancer, histologic study is mandatory in the presence of any lesion as the hysteroscopic view cannot completely replace the histologic study in patients with AUB. (C) 2006 AAGL. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The electromyographic activity of the shoulder muscles deltoid - anterior portion (DA) and pectoralis major - clavicular portion (PMC) was tested on 24 male volunteers using a 2 channel TEC A TE4 electromyograph and Hewlett Packard surface electrodes during the execution of four different modalities of frontal-lateral cross, dumbbells exercises. The results showed that all of the tested exercises developed high levels of action potential for both muscles. So, we jusfity the indication of all of them for physical fitness programmes for DA and PMC. Some suggestions to the use of the tested exercises are presented.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A simple, rapid, selective and specific high performance liquid chromatographic (HPLC) method for quantitative analysis of the triamcinolone in polylactide-co-glycolide acid (PLGA) microparticles was developed. The chromatographic parameters were reversed-phase C18 column, 250mm x 4.6mm, with particle size 5 μm. The column oven was thermostated at 35°C ± 2°C. The mobile phase was methanol/water 45:55 (v/v) and elution was isocratic at a flow-rate of 1 mL.mL-1. The determinations were performed using a UV-Vis detector at 239 nm. The injected sample volume was 10 μL. The standard curve was linear (r2 > 0.999) in the concentration range 100-2500 ng.mL-1. The method showed adequate precision, with a relative standard deviation (RSD) was smaller than 3%. The accuracy was analyzed by adding a standard drug and good recovery values were obtained for all drug concentrations used. The method showed specificity and selectivity with linearity in the working range and good precision and accuracy, making it very suitable for quantitation of triamcinolone in PLGA microparticles.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Until mid 2006, SCIAMACHY data processors for the operational retrieval of nitrogen dioxide (NO2) column data were based on the historical version 2 of the GOME Data Processor (GDP). On top of known problems inherent to GDP 2, ground-based validations of SCIAMACHY NO2 data revealed issues specific to SCIAMACHY, like a large cloud-dependent offset occurring at Northern latitudes. In 2006, the GDOAS prototype algorithm of the improved GDP version 4 was transferred to the off-line SCIAMACHY Ground Processor (SGP) version 3.0. In parallel, the calibration of SCIAMACHY radiometric data was upgraded. Before operational switch-on of SGP 3.0 and public release of upgraded SCIAMACHY NO2 data, we have investigated the accuracy of the algorithm transfer: (a) by checking the consistency of SGP 3.0 with prototype algorithms; and (b) by comparing SGP 3.0 NO2 data with ground-based observations reported by the WMO/GAW NDACC network of UV-visible DOAS/SAOZ spectrometers. This delta-validation study concludes that SGP 3.0 is a significant improvement with respect to the previous processor IPF 5.04. For three particular SCIAMACHY states, the study reveals unexplained features in the slant columns and air mass factors, although the quantitative impact on SGP 3.0 vertical columns is not significant.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The validation of a microbiological assay, applying agar diffusion method for determination of the active of cefuroxime in power for injection, is described. Using a strain of Micrococcus luteus ATCC 9341 as the test organism, cefuroxime was measured in concentrations ranging from 30.0 to 120.0 μg/mL. The method validation showed that it is linear (r = 0.9999), precise (relative standard deviation = 0.37%) and accurate (it measured the added quantities). Microbiological assay is satisfactory for quantitation of cefuroxime in powder for injection and the validity of the proposed bioassay, which is a simple and a useful alternative methodology for cefuroxime determination in routine quality control.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background and Objective: Simple Measure of the Impact of Lupus Erythematosus in Youngsters (SMILEY) is a health-related quality of life (HRQOL) assessment tool for pediatric systemic lupus erythematosus (SLE), which has been translated into Portuguese for Brazil. We are reporting preliminary data on cross-cultural validation and reliability of SMILEY in Portuguese (Brazil). Methods: In this multi-center cross-sectional study, Brazilian children and adolescents 5-18 years of age with SLE and parents participated. Children and parents completed child and parent reports of Portuguese SMILEY and Portuguese Pediatric Quality of Life Inventory (PedsQLTM) Generic and Rheumatology modules. Parents also completed the Childhood Health Assessment Questionnaire (CHAQ). Physicians completed the SLE disease activity index (SLEDAI), Physician's Global Assessment of disease activity (PGA) and Systemic Lupus Erythematosus International Collaborating Clinics ACR Damage Index (SDI). Results: 99 subjects (84 girls) were enrolled; 93 children and 97 parents filled out the SMILEY scale. Subjects found SMILEY relevant and easy to understand and completed SMILEY in 5-15 minutes. Brazilian SMILEY was found to have good psychometric properties (validity and reliability), and the child-parent agreement was moderate. Conclusion: SMILEY may eventually be used routinely as a research/clinical tool in Brazil. It may be also adapted for other Portuguese-speaking nations offering critical information regarding the effect of SLE on HRQOL for children with SLE. © The Author(s), 2012.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objectives To consensually validate the operational definitions of the nursing diagnoses activity intolerance, excessive fluid volume, and decreased cardiac output in patients with decompensated heart failure. Method Consensual validation was performed in two stages: analogy by similarity of defining characteristics, and development of operational definitions and validation with experts. Results A total of 38 defining characteristics were found. Operational definitions were developed and content-validated. One hundred percent of agreement was achieved among the seven experts after five rounds. Ascites was added in the nursing diagnosis excessive fluid volume. Conclusion The consensual validation improves interpretation of human response, grounding the selection of nursing interventions and contributing to improved nursing outcomes. Implications for Practice Support the assessment of patients with decompensated heart failure. Objetivos Realizar a validacAo consensual das definicoes operacionais dos diagnosticos de enfermagem Intolerancia a atividade, Volume de liquidos excessivo e Debito cardiaco diminuido em pacientes com insuficiencia cardiaca descompensada. Metodo ValidacAo consensual em duas etapas: Analogia de semelhanca das caracteristicas definidoras e desenvolvimento de definicoes operacionais e validacAo com expertst. Resultados Foram encontradas 38 caracteristicas definidoras para os diagnosticos de enfermagem. Suas definicoes operacionais foram desenvolvidas e seu conteudo validado. Os resultados mostram que houve 100% de concordancia entre os sete experts apos cinco rodada. As definicoes operacionais foram classificadas com base no nivel de concordanica. Ascite foi acrescentada ao diagnostico Volume de liquidos excessivo. ConclusAo A validacAo consensual melhora a interpretacAo das respostas humanas, embasando a selecAo de intervencoes de enfermagem e contribuindo para melhorar os resultados. Implicacoes Para A Pratica Apoio a avaliacAo dos pacientes com insuficiencia cardiaca descompensada.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Este trabalho apresenta resultados acerca das propriedades psicométricas da Escala de atitudes frente ao HIV/AIDS. Os dados, provenientes de uma amostra de 549 alunos entre universitários, ensinos médio e ensino fundamental. MÉTODOS: Os dados foram tratados pelo método dos componentes principais da análise fatorial. A análise final, postulado um eigenvalue mínimo de 2, resultou cinco fatores. Foram eliminados itens que apresentaram carga fatorial menor que 0,30. Neste estudo, o menor alfa observado foi de 0,79. Portanto, é provável que todos os 47 itens do instrumento final elaborado meçam o mesmo construto: atitude frente ao HIV/AIDS. RESULTADOS: Escores inferiores a 96 foram considerados fraco grau de conhecimento sobre HIV/AIDS; entre 96 e 192 moderado grau de conhecimento e acima de 192 alto grau de conhecimento sobre HIV/AIDS. Foram estabelecidos os fatores: 1, 2 e 3, sendo fator geral de percepção da informação técnico-científica; fator de percepção da informação técnico-científica versus sexualidade e preconceito; fator de percepção da informação técnico-científica no uso de drogas, respectivamente. CONCLUSÕES: O alfa de Cronbach encontrado para a escala como um todo foi de 0,859, sugerindo fortemente a existência da fidedignidade do instrumento que se mostrou útil para avaliar o grau de conhecimento acerca do HIV/AIDS e o risco decorrente do desconhecimento, entre estudantes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We report the cross-cultural adaptation and validation into Brazilian-Portuguese of the parent's version of two health related quality of life instruments. The Childhood Health Assessment Questionnaire (CHAQ) is a disease specific health instrument that measures functional ability in daily living activities in children with juvenile idiopathic arthritis (JIA). The Child Health Questionnaire (CHQ) is a generic health instrument designed to capture the physical and psychosocial well-being of children regardless the underlying disease. The Brazilian CHAQ was revalidated, while the CHQ has been derived from the Portuguese version. A total of 471 subjects were enrolled: 157 patients with JIA (27% systemic onset, 38% polyarticular onset, 9% extended oligoarticular subtype, and 26% persistent oligoarticular subtype) and 314 healthy children. The CHAQ discriminated clinically healthy subjects from JIA patients, with the systemic, polyarticular and extended oligoarticular subtypes having a higher degree of disability, pain, and lower overall well-being scores when compared to their healthy peers. Also the CHQ discriminated clinically healthy subjects from JIA patients, with the systemic onset, polyarticular onset and extended oligoarticular subtypes having a lower physical and psychosocial well-being score when compared to their healthy peers. In conclusion the Brazilian versions of the CHAQ-CHQ are reliable and valid tools for the combined physical and psychosocial assessment of children with JIA. © Copyright Clinical and Experimental Rheumatology 2001.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Neuropsychiatric symptoms (NPS) affect almost all patients with dementia and are a major focus of study and treatment. Accurate assessment of NPS through valid, sensitive and reliable measures is crucial. Although current NPS measures have many strengths, they also have some limitations (e.g. acquisition of data is limited to informants or caregivers as respondents, limited depth of items specific to moderate dementia). Therefore, we developed a revised version of the NPI, known as the NPI-C. The NPI-C includes expanded domains and items, and a clinician-rating methodology. This study evaluated the reliability and convergent validity of the NPI-C at ten international sites (seven languages). Methods: Face validity for 78 new items was obtained through a Delphi panel. A total of 128 dyads (caregivers/patients) from three severity categories of dementia (mild = 58, moderate = 49, severe = 21) were interviewed separately by two trained raters using two rating methods: the original NPI interview and a clinician-rated method. Rater 1 also administered four additional, established measures: the Apathy Evaluation Scale, the Brief Psychiatric Rating Scale, the Cohen-Mansfield Agitation Index, and the Cornell Scale for Depression in Dementia. Intraclass correlations were used to determine inter-rater reliability. Pearson correlations between the four relevant NPI-C domains and their corresponding outside measures were used for convergent validity. Results: Inter-rater reliability was strong for most items. Convergent validity was moderate (apathy and agitation) to strong (hallucinations and delusions; agitation and aberrant vocalization; and depression) for clinician ratings in NPI-C domains. Conclusion: Overall, the NPI-C shows promise as a versatile tool which can accurately measure NPS and which uses a uniform scale system to facilitate data comparisons across studies. Copyright © 2010 International Psychogeriatric Association.