13 resultados para integrated web platform
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
iCONVERT: an integrated device for the UV-assisted determination of H2S via mid-infrared gas sensors
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Service oriented architectures (SOA) based on Simple Object Access Protocol (SOAP) Web services have attracted the attention of enterprises mainly for business-to-business integration and to create composite applications that execute business processes. An existing problem is the lack of preoccupation with non technical users due to the fact that to create a composite application to fulfill users needs, it is necessary to be in contact with IT staff. To overcome this issue, enterprises can take advantage of web 2.0, 'introducing in the development stage some technologies like mashups and some concepts like user empowerment, collaborative work and collective intelligence. Some results [3] [13] have shown how web 2.0 concepts can help non technical users to produce relative complex business processes. However, traditional enterprise requirements goes beyond typical web 2.0 solutions in several aspects: (1) traditional enterprise systems are based on heterogeneous stack of technologies that are not directly exploitable from a web-based client (where SOAP web services play an important role); (2) web browsers set some cross-domain security constraints making difficult to integrate services from diverse domains. In this paper, a contribution to two web 2.0 research projects [14] [15] partially solves the problems described: provide a way to invoke cross-domain backend services (based on SOAP technologies) directly only using clientside languages, without a need for any adaptation layer. © 2010 ACM.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A method is proposed for the simultaneous determination of Al, As, Cu, Fe, Mn, and Ni in fuel ethanol by electrothermal atomic absorption spectrometry (ETAAS) using W-Rh permanent modifier together with Pd(NO3)(2) + Mg(NO3)(2) conventional modifier. The integrated platform of a transversely heated graphite atomizer (THGA) was treated with tungsten, followed by rhodium, forming a deposit containing 250 mug W + 200 mug Rh. A 500-muL, volume of fuel ethanol was diluted with 500 muL, of 0.14 mol L-1 HNO3 in an autosampler cup of the spectrometer. Then, 20 muL, of the diluted ethanol was introduced into the pretreated graphite platform followed by the introduction of 5 mug Pd(NO3)(2) + 3 mug Mg(NO3)(2). The injection of this modifier was required to improve arsenic and iron recoveries in fuel ethanol. Calibrations were carried out using multi-element reference solutions prepared in diluted ethanol (1 + 1, v/v) acidified to 0. 14 mol L-1 HNO3. The pyrolysis and atomization temperatures of the heating program were 1200degreesC and 2200degreesC, respectively, which were obtained with multielement reference solutions in acidic diluted ethanol (1 + 1, v/v; 0. 14 mol L-1 HNO3). The characteristic masses for the simultaneous determination in ethanol fuel were 78 pg Al, 33 pg As, 10 pg Cu, 14 pg Fe, 7 pg Mn, and 24 pg Ni. The lifetime of the pretreated tube was about 700 firings. The detection limits (D.L.) were 1.9 mug L-1 Al, 2.9 mug L-1 As, 0.57 mug L-1.Cu, 1.3 mug L-1 Fe, 0.40 mug L-1 Mn, and 1.3 mug L-1 Ni. The relative standard deviations (n = 12) were 4%, 4%, 3%, 1.5%, 1.2%, and 2.2% for Al, As, Cu, Fe, Mn, and Ni, respectively. The recoveries of Al, As, Cu, Fe, Mn, and Ni added to the fuel ethanol samples varied from 81% to 95%, 80% to 98%, 97% to 109%, 85% to 107%, 98% to 106% and 97% to 103%, respectively. Accuracy was checked for the Al, As, Cu, Fe, Mn, and Ni determination in 10 samples purchased at a local gas station in Araraquara-SP City, Brazil. A paired t-test showed that at the 95% confidence level the results were in agreement with those obtained by single-element ETAAS.
Resumo:
Virtual platforms are of paramount importance for design space exploration and their usage in early software development and verification is crucial. In particular, enabling accurate and fast simulation is specially useful, but such features are usually conflicting and tradeoffs have to be made. In this paper we describe how we integrated TLM communication mechanisms into a state-of-the-art, cycle-accurate, MPSoC simulation platform. More specifically, we show how we adapted ArchC fast functional instruction set simulators to the MPARM platform in order to achieve both fast simulation speed and accuracy. Our implementation led to a much faster hybrid platform, reaching speedups of up to 2.9 and 2.1x on average with negligible impact on power estimation accuracy (average 3.26% and 2.25% of standard deviation). © 2011 IEEE.
Resumo:
Purpose: To evaluate the stress distribution in peri-implant bone by simulating the effect of an implant with microthreads and platform switching on angled abutments through tridimensional finite element analysis. The postulated hypothesis was that the presence of microthreads and platform switching would reduce the stress concentration in the cortical bone. Methods: Four mathematical models of a central incisor supported by an implant (5.0mm×13mm) were created in which the type of thread surface in the neck portion (microthreaded or smooth) and the diameter of the angled abutment connection (5.0 and 4.1mm) were varied. These models included the RM (regular platform and microthreads), the RS (regular platform and smooth neck surface), the SM (platform switching and microthreads), and the SS (platform switching and smooth neck). The analysis was performed using ANSYS Workbench 10.0 (Swanson Analysis System). An oblique load (100N) was applied to the palatine surface of the central incisor. The bone/implant interface was considered to be perfectly integrated. Values for the maximum (σmax) and minimum (σmin) principal stress, the equivalent von Mises stress (σvM), and the maximum principal elastic strain (e{open}max) for cortical and trabecular bone were obtained. Results: For the cortical bone, the highest σmax (MPa) were observed for the RM (55.1), the RS (51.0), the SM (49.5), and the SS (44.8) models. The highest σvM (MPa) were found for the RM (45.4), the SM (42.1), the RS (38.7), and the SS models (37). The highest values for σmin were found for the RM, SM, RS and SS models. For the trabecular bone, the highest σmax values (MPa) were observed in the RS model (6.55), followed by the RM (6.37), SS (5.6), and SM (5.2) models. Conclusion: The hypothesis that the presence of microthreads and a switching platform would reduce the stress concentration in the cortical bone was partially rejected, mainly because the microthreads increased the stress concentration in cortical bone. Only platform switching reduced the stress in cortical bone. © 2012 Japan Prosthodontic Society.
Resumo:
Pós-graduação em Ciência da Computação - IBILCE
Resumo:
The aim of this study was to evaluate stress distribution on the pen-implant bone, simulating the influence of Nobel Select implants with straight or angulated abutments on regular and switching platform in the anterior maxilla, by means of 3-dimensional finite element analysis. Four mathematical models of a central incisor supported by external hexagon implant (13 mm x 5 mm) were created varying the platform (R, regular or S. switching) and the abutments (S, straight or A, angulated 15 degrees). The models were created by using Mimics 13 and Solid Works 2010 software programs. The numerical analysis was performed using ANSYS Workbench 10.0. Oblique forces (100 N) were applied to the palatine surface of the central incisor. The bone/implant interface was considered perfectly integrated. Maximum (sigma(max)) and minimum (sigma(min)) principal stress values were obtained. For the cortical bone the highest stress values (sigma(max)) were observed in the RA (regular platform and angulated abutment, 51 MPa), followed by SA (platform switching and angulated abutment, 44.8 MPa), RS (regular platform and straight abutment, 38.6 MPa) and SS (platform switching and straight abutment, 36.5 MPa). For the trabecular bone, the highest stress values (sigma(max)) were observed in the RA (6.55 MPa), followed by RS (5.88 MPa), SA (5.60 MPa), and SS (4.82 MPa). The regular platform generated higher stress in the cervical periimplant region on the cortical and trabecular bone than the platform switching, irrespective of the abutment used (straight or angulated).
Resumo:
Developmental Coordination Disorder (DCD), a chronic and usually permanent condition found in children, is characterized by motor impairment that interferes with a child's activities of daily living and with academic achievement. One of the most popular tests for the quantitative diagnosis of DCD is the Movement Assessment Battery for Children (MABC). Based on the Battery's standardized scores, it is possible to identify children with typical development, children at risk of developing DCD, and children with DCD. This article describes a computational system we developed to assist with the analysis of results obtained in the MABC test. The tool was developed for the web environment and its database provides integration of MABC data. Thus, researchers around the world can share data and develop collaborative work in the DCD field. In order to help analysis processes, our system provides services for filtering data to show more specific sets of information and present the results in textual, table, and graphic formats, allowing easier and more comprehensive evaluation of the results.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This case study aims at identifying how a community of secondary school students selects web-based information and factors associated with the reliability of online reference sources during their collaborative inquiry (co-inquiry) projects. This study, conducted in a public secondary school in Brazil, focused on information literacy skills for collaborative open learning (colearning). The research is based on qualitative content analysis implemented on the online platform weSPOT. Although students are mindful of the importance of comparing different sources of information they seem not to be aware of reliability in online environments. Teacher's guidance is essential to support co-learners in developing competences, particularly related to critical thinking.
Resumo:
This paper presents the development of a Web application called CityFreedom based on 3D modeling. The developed system demonstrates the use of most revolutionary and innovative techniques to create Web portals with the integrated 3D navigation scenarios to their own pages, without requiring any kind of plug-ins or external software. Everything works on the basis of compatible browsers. The CtyFreedom aims to give the user the feeling of immersion in virtual reality so get to interact with a three-dimensional city in order to see new places, traveling in an area of town that has always thought of knowing or even analyze establishments long before attend-them. It's the freedom to know and traveling around the city in a simple and trivial way. It is a new trend, the future of Web systems development
Resumo:
The applications market is heated and has grown in the recent years, every day thousands of apps are downloaded and many of these are electronic games and are intended for smartphones and tablets. The electronic games are often integrated with an online system which has the function of providing extra functionality to the players. This project proposes the development of online support system to a game designed for mobile devices, consisting of a website and a database which has the function of storing data online beyond a system called the back end which has the function to integrate all the modules mentioned previously