78 resultados para Resonant tunneling diode

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper we show that the electronic properties of multi-open dots structures are strongly modified by even smalt changes in their geometries. Our discussion of these effects is done in terms of the interaction among localized states (dot-like) and extended states (channel-like), from which a Fano resonance situation arises.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new double channel field-effect structure based on delta-doping technology is proposed Resonant tunneling between the channels is employed to control the transport along the interface plane. A realistic simulation is performed for several temperatures. We solve the Schrodinger and Poisson equations self-consistently and have found that a large peak-to-valley ratio in the current-voltage characteristic occurs at the whole range of temperature investigated this effect indicates the potential application of this phenomenon for switching devices, where the transversal conductivity can be controlled due to the coupling between states belonging to different channels.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of manganese on the vibrational properties of Ga(1-x)Mn(x)N (0 <= x <= 0.18) films has been investigated by Raman scattering using 488.0 and 632.8 nm photon excitations. The first-order transverse and longitudinal optical GaN vibrational bands were observed in the whole composition range using both excitations, while the corresponding overtones, as well as a prominent peak located in 1238 cm(-1) (153.5 meV) were only observed in the Mn-containing films under 488.0 nm excitation. We propose that the peak observed at 1238 cm(-1) is due to resonant Mn local vibrational modes, the excitation process being related to electronic transitions involving the Mn acceptor band.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: the objective of this study was to determine if the zona thinning (ZT) technique improved the rates of implantation and clinical pregnancy for patients aged, greater than or equal to38 years submitted to an ICSI program.Methods: A total of 100 patients submitted to ICSI and aged, greater than or equal to38 years were divided in a prospective and randomized manner into two groups: Group I - patients submitted to ZT (n = 50); a laser diode with 1.48 mum wavelength (Fertilaser) was used for the ZT procedure with 1-2 irradiations of 10 ms applied to four different positions on the zona pellucida (ZP) of each embryo to thin 60-90% of the ZP (each point with a 15-20 mum length of ZT). Group II - patients with no ZT (n = 50). In both groups, embryo transfer was performed on the second or third day.Results: the age of Group I patients (39.8 +/- 1.3) did not differ (p = 0.67) from that of Group II patients (40 +/- 1.9). The number of oocytes retrieved at metaphase II from Group I (6.4 +/- 4.2) and Group II (6.8 +/- 5) was similar (p = 0.94). Normal fertilization rates and cleavage rates were similar (p = 0.78 and p = 0.63, respectively) for Group I (71.5 +/- 22% and 96.7 +/- 11%) and Group II (73.5 +/- 19.7% and 96 +/- 11%, respectively). The number of embryos transferred was similar (p = 0.53) for the two groups (Group I = 3.1 +/- 1.3; Group II = 2.9 +/- 1.1). The thickness of the ZP of Group I embryos (16.9 +/- 2.4 mum) did not differ (p = 0.97) from that of Group II embryos (16.9 +/- 2.3 mum). The rates of embryo implantation and clinical pregnancy per embryo transfer were similar (p = 0.67, p = 0.61) for Group I (7 and 16%, respectively) and for Group II (8.2 and 22%, respectively).Conclusions: These results suggest that ZT in the population aged, 38 years may have no impact on ICSI success rates. However, this conclusion is limited to a situation in which length of the laser ZT was less than or equal to 20 mum and the laser was applied to four different positions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: the aim of this study was to evaluate in vitro, by scanning electron microscopy (SEM), the adhesion of blood components on root surfaces irradiated with Er:YAG (2.94 mu m) and GaAlAs Diode (808 nm) lasers and the effects on the morphology of irradiated root surfaces.Methods: One hundred samples of human teeth were obtained. They were previously planed and scaled with manual instruments and divided into five groups of 20 samples each: G1 (control group) - absence of treatment; G2 - Er:YAG laser (7.6 J/cm(2)); G3 - Er:YAG laser (12.9 J/cm(2)); G4 - Diode laser (90 J/cm(2)) and G5 - Diode laser (108 J/cm(2)). After these treatments, 10 samples of each group received a blood tissue but the remaining 10 did not. After laboratory treatments, the samples were obtained by SEM, the photomicrographs were analysed by the score of adhesion of blood components and the results were statistically analysed (Kruskall-Wallis and Mann-Whitney test).Results: In relation to the adhesion of blood components, the study showed no significant differences between the control group and the groups treated with Er:YAG laser (p = 0.9633 and 0.6229). Diode laser radiation was less effective than control group and Er:YAG laser radiation (p < 0.01).Conclusion: None of the proposed treatments increased the adhesion of blood components in a significant way when compared to the control group. Although the Er:YAG laser did not interfere in the adhesion of blood components, it caused more changes on the root surface, whereas the Diode laser inhibited the adhesion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: the aim of the present study was to compare the effects of Er:YAG and diode laser treatments of the root surface on intrapulpal temperature after scaling and root planing with hand instruments.Methods: Fifteen extracted single-rooted teeth were scaled and root planed with hand instruments. The teeth were divided into 3 groups of 5 each and irradiated on their buccal and lingual surfaces: group A: Er:YAG laser, 2.94 mum/100 mJ/10 Hz/ 30 seconds; group B: diode laser, 810 nm/1.0 W/0.05 ms/30 seconds; group C: diode laser, 810 nm/1.4 W/0.05 ms/30 seconds. The temperature was monitored by means of a type T thermocouple (copper-constantan) positioned in the pulp chamber to assess pulpal temperature during and before irradiation. Afterwards, the specimens were longitudinally sectioned, and the buccal and lingual surfaces of each root were analyzed by scanning electron microscopy.Results: In the Er:YAG laser group, the thermal analysis revealed an average temperature of -2.2 +/- 1.5degreesC, while in the diode laser groups, temperatures were 1.6 +/- 0.8degreesC at 1.0 W and 3.3 +/- 1.0degreesC at 1.4 W. Electronic micrographs revealed that there were no significant morphological changes, such as charring, melting, or fusion, in any group, although the specimens were found to be more irregular in the Er:YAG laser group.Conclusions: the application of Er:YAG and diode lasers at the utilized parameters did not induce high pulpal temperatures. Root surface irregularities were more pronounced after irradiation with an Er:YAG laser than with a diode laser.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this in vivo study was to evaluate the thermal effects caused by 810 nm 1.2 W diode laser irradiation of periodontal tissues. Despite all data available concerning the laser application for periodontal treatment, one of the most relevant challenges is to prevent the harmful tissue heating induced by different clinical protocols. Periodontal pockets were induced at molars in 96 rats. Several irradiation powers under CW mode were investigated: 0, 400, 600, 800, 1000, 1200 mW. The pockets were irradiated using a 300 A mu m frontal illumination fiber. The animals were killed at 4 or 10 days after irradiation. The mandible was surgically removed and histologically processed. The histological sections stained with H/E demonstrated that irradiation parameters up to 1000 mW were thermally safe for the periodontal tissues. The sections stained with Brown & Brenn technique evidenced bacteria in the periodontal tissues. Consequently, the diode laser irradiation as a unique treatment was not capable to eliminate bacteria of the biofilm present in the pockets. According to the methodology used here, it was concluded that the thermal variation promoted by a diode laser can cause damage to periodontal tissues depending on the energy density used. The 1.2 W diode laser irradiation itself does not control the bacteria present in the biofilm of the periodontal pockets without mechanical action. The knowledge of proper high intensity laser parameters and methods of irradiation for periodontal protocols may prevent any undesirable thermal damage to the tissues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dentin hipersensitivity (DH) is a relatively common clinical condition, especially in periodontal patients after treatment. In this study it was evaluated 28 teeth who presented dentin hypersensitivity. The teeth were subjected to clinical and radiographic exams and were divided into groups following the treatment and the time of examination after application proposed: GI: PO 3% (Potassium Oxalate-group control)/Baseline; GII: PO 3%/3 days after first session; GIII: PO 3%/6 days; GIV: PO 3%/30 days; GV: PO 3%/60 days; GVI: PO 3%/90 days; GVII: Laser (Low-level diode laser with 110 mW/cm(2))/Baseline; GVIII: Laser/7 days after first session; GIX: Laser/14 days; GX: Laser/30 days; GXI: Laser/60 days; and GXII: Laser/90 days. The groups I-VI, the teeth were subjected to 3 applications (GI-GIII) of desensitizing agent at regular intervals of seven days. The Groups VII-XI, each tooth was subjected to three applications (GVII GIX) in three different points (mesial, meddle and distal surfaces) with an interval of 72 h. The time of application in each point was of 33 s and the patients from both groups were followed up to 90 days. The nonparametric test Friedman (alpha = 0.05) was applied and the test of Mann Whitney (alpha = 0.05) was used to compare the time of examination between groups. The application of Laser was effective 6 days after first session and to PO was 30 days. It was observed that both treatments were effective for the reduction of dentin hypersensitivity, however the laser presented better effectiveness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using bidimensional arenas, the construction and spatial dispersion of tunnels constructed by Coptotermes gestroi and Heterotermes tenuis (Rhinotermitidae) was determined under different laboratory conditions. Workers of both species showed an increase of the tunneled area with the rise in temperature. The activity of workers of C gestroi also increased with the rise in soil moisture. Primary tunnels showed a high degree of dispersion in the arenas for all treatments. The presence of food did not influence the tunneling pattern of C. gestroi; but for H. tenuis there was a significant decrease in the number of tunnels. In addition, the type of substrate affected the tunneling pattern in both species. The understanding of food searching strategies of subterranean termites could contribute in the improvement of pest management programs based on the use of toxic baits. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dentin wall structural changes caused by 810-nm-diode laser irradiation can influence the sealing ability of endodontic sealers. The objective of this study was to evaluate the apical leakage of AH Plus and RealSeal resin-based sealers with and without prior diode laser irradiation. Fifty-two single-rooted mandibular premolars were prepared and divided into 4 groups, according to the endodontic sealer used and the use or non-use of laser irradiation. The protocol for laser irradiation was 2.5W, continuous wave in scanning mode, with 4 exposures per tooth. After sample preparation, apical leakage of 50% ammoniacal silver nitrate impregnation was analyzed. When the teeth were not exposed to irradiation, the Real Seal sealer achieved the highest scores, showing the least leakage, with significant differences at the 5% level (Kruskal-Wallis test, p = 0.0004), compared with AH Plus. When the teeth were exposed to the 810-nm-diode laser irradiation, the sealing ability of AH Plus sealer was improved (p = 0282). In the Real Seal groups, the intracanal laser irradiation did not interfere with the leakage index, showing similar results in the GRS and GRSd groups (p = 0.1009).