36 resultados para RELIABILITY ANALYSIS
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
This work presents a methodology for elastic-plastic fracture reliability analysis of plane and axisymmetric structures. The structural reliability analysis is accomplished by means of the FORM analytical method. The virtual crack extension technique based on a direct minimization of potencial energy is utililized for the calculation of the energy release rate. Results are presented to illustrate the performance of the adopted methodology.
Resumo:
This paper explains why the reliability assessment of energy limited systems requires more detailed models for primary generating resources availability, internal and external generating dispatch and customer demand than the ones commonly used for large power systems and presents a methodology based on the full sequential Montecarlo simulation technique with AC power flow for their long term reliability assessment which can properly include these detailed models. By means of a real example, it is shown how the simplified modeling traditionally used for large power systems leads to pessimistic predictions if it is applied to an energy limited system and also that it cannot predict all the load point adequacy problems. © 2006 IEEE.
Resumo:
This article shows an analysis of the electrical parameters of a three-phase transmission line section using a relatively new design for steel towers characterized by 280 meters high. These main features, the height of the line conductors and distance between them, are intrinsically related to the longitudinal and transversal parameters of the line. By this means, an analysis was carried out in order to show the electrical variations between a transmission line using the new technology and a conventional 440-kV line through a wide range of frequencies and a variable soil resistivity. © 2012 The Institution of Engineering and Technology.
Resumo:
Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Currently, the need of reliable coordinates has been one of the main objectives of the scientific and practice community. Thus, the robustness analysis of a geodetic network, aims, at analyzing if the network is robust or not, based on the maximum undetectable errors. The network will be robust if the influence of these errors is small, otherwise it is weak, or not robust. This analysis is performed with the merger of two techniques, one which deals with the statistical analysis of reliability and the other one with the geometric strength analysis. The reliability analysis will provide the maximum error that cannot be detected by tests, after the adjustment. After finding these errors, the geometric strength analysis will determine the potential strain that the network will have, based on these errors. It is emphasized that the robustness analysis doesn't depend of the datum, reflecting only the geometry of the network and the accuracy of the observations (VANÌCEK et al., 2001). Therefore, this work aims at contributing to the scientific research on geodetic networks, checking the same, based on their geometry and observations.
Resumo:
Although measurement errors can impair statistical analysis, reliability analysis has been neglected in applied microbiology. This study assessed the intra-rater reproducibility of the Agar-based method for estimation of phospholipase activity (Pz). Pz readings were performed twice by two examiners (E1, E2), either directly on plates or in photos, and both black and white backgrounds were used. Pz values were taken from one or triplicate colonies from each sample (n=30). Intra-examiner reproducibility was estimated using Intraclass Correlation Coefficient (ICC). For both examiners, reading triplicate (ICCE1=0.91, ICCE2=0.86) was better than one colony (ICCE1=0.86, ICCE2=0.80). E1 had an excellent concordance when measurements were performed on photos using a white background (ICC=0.95) and a good concordance in the other conditions
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Fisioterapia - FCT
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Objective, the objective of this study was to evaluate the reliability of in vivo staining with toluidine blue in the detection of oral epithelial dysplasia, in situ carcinoma, and invasive squamous cell carcinomas in potentially malignant epithelial lesions (PMELs) and superficial oral ulcerations suggesting malignancy.Study design. Fifty patients with PMELs and superficial oral ulcerations suggestive of malignancy were selected from those treated at the Oral Medicine Service, Faculty of Dentistry, Araraquara, Brazil. All lesions were submitted to staining with an aqueous solution of 1% toluidine blue, followed by biopsy and histologic analysis. The sensitivity, specificity, and positive and negative predictive values were calculated.Results. Histologic diagnosis revealed that 14% of the lesions analyzed were in situ carcinoma and invasive squamous cell carcinomas, 12% were epithelial dysplasias, 13% were keratosis, 40% were lichen planus, and 8% were other benign lesions. The sensitivity uf the staining was 77%, the specificity 67%, and the positive and negative predictive values 43.5% and 88.9%, respectivelyConclusions, Staining with toluidine blue was demonstrated to be highly reliable in the detection of in situ carcinoma acid invasive squamous cell carcinoma, because false-negative results for the lesions did not occur. Toluidine blue staining is an adjunct to clinical judgment and not a substitute for either judgment or biopsy.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Immunochemical methods have increased considerably in the past years, and many examples of small and large scale studies have demonstrated the reliability of the immunotechniques for control and monitoring gf contaminant residues in different kinds of samples. Application of the immunoassay (IA) methods in pesticide residue control is an area with enormous potential for growth. The most extensively studied IA is the enzyme-linked absorbent assay (ELISA), but several other approaches, that include radioimmunoassay and immunoaffinity chromatography, have been also developed recently. In comparison with classical analytical methods, IA methods offer the possibility of highly sensitive, relatively vapid, and cost-effective measurements. This paper introduces the general IAs used until now, focusing on their use in pesticide analysis, and discussing briefly the effects of interferences from solvent residues or matrix components on the IA performance. Numerous immunochemical methods commonly used for pesticide determination in different samples such as food, crop and environmental samples are presented.
Resumo:
The aims of this study were to evaluate the reliability and to validate a Brazilian version of Oral Health Impact Profile for assessing edentulous subjects (OHIP-EDENT), an inventory for measuring oral health-related quality of life of edentulous subjects. The sample comprised 65 complete denture wearers (23 men, mean age of 69.1 +/- 10.3 years). The translated OHIP-EDENT was applied on two occasions with a washout period of 3 months. Reliability was assessed by an internal consistency analysis and a test-retest approach. A preliminary validation process was conducted by a qualitative approach/interview. Results of internal consistency showed a Cronbach's alpha of 0.86 or 0.90 for the first or second appointment respectively. Through the test-retest analysis, an intra-class correlation coefficient of 0.57 was found, and individual answers reflected a broad range of agreement. Interviewed volunteers (n = 6) comprehended most questions well. In conclusion, the Brazilian version of OHIP-EDENT is adequate for assessing the oral health-related quality of life for edentulous subjects.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)