Intra-examiner reproducibility of the agar plate method for estmation of phospholipase activity in candida albicans
Contribuinte(s) |
Universidade Estadual Paulista (UNESP) |
---|---|
Data(s) |
06/08/2015
06/08/2015
2013
|
Resumo |
Although measurement errors can impair statistical analysis, reliability analysis has been neglected in applied microbiology. This study assessed the intra-rater reproducibility of the Agar-based method for estimation of phospholipase activity (Pz). Pz readings were performed twice by two examiners (E1, E2), either directly on plates or in photos, and both black and white backgrounds were used. Pz values were taken from one or triplicate colonies from each sample (n=30). Intra-examiner reproducibility was estimated using Intraclass Correlation Coefficient (ICC). For both examiners, reading triplicate (ICCE1=0.91, ICCE2=0.86) was better than one colony (ICCE1=0.86, ICCE2=0.80). E1 had an excellent concordance when measurements were performed on photos using a white background (ICC=0.95) and a good concordance in the other conditions |
Formato |
2744-2751 |
Identificador |
http://www.amstat.org/meetings/jsm/2013/onlineprogram/AbstractDetails.cfm?abstractid=308949 JSM Proceedings, v. 2013, p. 2744-2751, 2013. 1543-3218 http://hdl.handle.net/11449/126097 0127570480681342 7167211040669505 |
Idioma(s) |
eng |
Relação |
JSM Proceedings |
Direitos |
closedAccess |
Palavras-Chave | #Intra-examiner reproducibility #Intraclass Correlation Coefficient #Phospholipase Activity #Candida albicans |
Tipo |
info:eu-repo/semantics/article |