31 resultados para Predictive values

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Decreased heart rate variability (HRV) is related to higher morbidity and mortality. In this study we evaluated the linear and nonlinear indices of the HRV in stable angina patients submitted to coronary angiography. Methods. We studied 77 unselected patients for elective coronary angiography, which were divided into two groups: coronary artery disease (CAD) and non-CAD groups. For analysis of HRV indices, HRV was recorded beat by beat with the volunteers in the supine position for 40 minutes. We analyzed the linear indices in the time (SDNN [standard deviation of normal to normal], NN50 [total number of adjacent RR intervals with a difference of duration greater than 50ms] and RMSSD [root-mean square of differences]) and frequency domains ultra-low frequency (ULF) ≤ 0,003 Hz, very low frequency (VLF) 0,003 - 0,04 Hz, low frequency (LF) (0.04-0.15 Hz), and high frequency (HF) (0.15-0.40 Hz) as well as the ratio between LF and HF components (LF/HF). In relation to the nonlinear indices we evaluated SD1, SD2, SD1/SD2, approximate entropy (-ApEn), α1, α2, Lyapunov Exponent, Hurst Exponent, autocorrelation and dimension correlation. The definition of the cutoff point of the variables for predictive tests was obtained by the Receiver Operating Characteristic curve (ROC). The area under the ROC curve was calculated by the extended trapezoidal rule, assuming as relevant areas under the curve ≥ 0.650. Results: Coronary arterial disease patients presented reduced values of SDNN, RMSSD, NN50, HF, SD1, SD2 and -ApEn. HF ≤ 66 ms§ssup§2§esup§, RMSSD ≤ 23.9 ms, ApEn ≤-0.296 and NN50 ≤ 16 presented the best discriminatory power for the presence of significant coronary obstruction. Conclusion: We suggest the use of Heart Rate Variability Analysis in linear and nonlinear domains, for prognostic purposes in patients with stable angina pectoris, in view of their overall impairment. © 2012 Pivatelli et al.; licensee BioMed Central Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: Our objective was to determine whether measurement of placenta growth factor (PLGF), inhibin A, or soluble fms-like tyrosine kinase-1 (sFlt-1) at 2 times during pregnancy would usefully predict subsequent preeclampsia ( PE) in women at high risk. STUDY DESIGN: We analyzed serum obtained at enrollment (12(0/7) to 19(6/7) weeks) and follow-up (24-28 weeks) from 704 patients with previous PE and/or chronic hypertension (CHTN) enrolled in a randomized trial for the prevention of PE. Logistic regression analysis assessed the association of log-transformed markers with subsequent PE; receiver operating characteristic analysis assessed predictive value. RESULTS: One hundred four developed preeclampsia: 27 at 37 weeks or longer and 77 at less than 37 weeks (9 at less than 27 weeks). None of the markers was associated with PE at 37 weeks or longer. Significant associations were observed between PE at less than 37 weeks and reduced PLGF levels at baseline (P =.022) and follow-up (P <.0001) and elevated inhibin A (P <.0001) and sFlt-1 (P =.0002) levels at follow-up; at 75% specificity, sensitivities ranged from 38% to 52%. Using changes in markers from baseline to follow-up, sensitivities were 52-55%. Associations were observed between baseline markers and PE less than 27 weeks (P <=.0004 for all); sensitivities were 67-89%, but positive predictive values (PPVs) were only 3.4-4.5%. CONCLUSION: Inhibin A and circulating angiogenic factors levels obtained at 12(0/7) to 19(6/7) weeks have significant associations with onset of PE at less than 27 weeks, as do levels obtained at 24-28 weeks with onset of PE at less than 37 weeks. However, because the corresponding sensitivities and/or PPVs were low, these markers might not be clinically useful to predict PE in women with previous PE and/or CHTN.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVOS: comparar dois testes de rastreamento do diabete gestacional. MÉTODOS: estudo prospectivo no qual foram avaliadas 356 gestantes, sem diagnóstico prévio do diabete melito, submetidas, de modo independente, a dois testes de rastreamento: associação glicemia de jejum e fator de risco (GJ+FR) e teste oral simplificado de tolerância à glicose (TTG50g). A comparação entre os métodos foi realizada pelos índices de sensibilidade (S), especificidade (E) e valores preditivos positivo (VPP) e negativo (VPN), resultados falsos, positivos (FP) e negativos (FN) e pela diferença dos resultados observados e esperados, avaliada pelo teste do Qui-quadrado (p<0,05). RESULTADOS: a associação GJ+FR determinou a confirmação diagnóstica em maior número de gestantes (187; 52,5%) que o TTG50g (49; 13,8%). Esta diferença foi significativa (p<0,05). A associação GJ+FR apresentou sensibilidade de 83,7% e valor preditivo negativo (VPN) de 95,3% em relação ao TTG50g. CONCLUSÕES: os índices elevados de sensibilidade e VPN da associação GJ+FR em relação ao TTG50g, sua simplicidade, praticidade, baixo custo e fácil replicação permitem sua indicação no rastreamento do diabete gestacional.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

CONTEXTO E OBJETIVO: A falta de consenso sobre os protocolos de rastreamento e diagnóstico do diabetes gestacional, associada às dificuldades na realização do teste oral simplificado do diabete gestacional (o teste de tolerância a 100 g de glicose, considerado padrão-ouro) justificam a comparação com alternativas. O objetivo deste trabalho é comparar o teste padrão-ouro a dois testes de rastreamento: associação de glicemia de jejum e fatores de risco (GJ + FR) e o teste oral simplificado de tolerância a 50 g de glicose (TTG 50 g), com o teste de tolerância a 100 g de glicose (TTG 100 g). TIPO DE ESTUDO E LOCAL: Estudo de coorte longitudinal, prospectivo, realizado no Serviço de Ginecologia e Obstetrícia do Hospital Universitário da Universidade Federal de Mato Grosso do Sul. MÉTODOS: 341 gestantes foram submetidas aos três testes. Calcularam-se os índices de sensibilidade (S), especificidade (E), valores preditivos (VPP e VPN), razões de probabilidade (RPP e RPN) e resultados falsos (FP e FN), positivos e negativos da associação GJ + FR e do TTG 50 g em relação ao TTG 100 g. Compararam-se as médias das glicemias de uma hora pós-sobrecarga (1hPS) com 50 e 100 g. Na análise estatística, empregou-se o teste t de Student, com limite de significância de 5%. RESULTADOS: A associação GJ + FR encaminhou mais gestantes (53,9%) para a confirmação diagnóstica que o TTG 50 g (14,4%). Os dois testes foram equivalentes nos índices de S (86,4 e 76,9%), VPN (98,7 e 98,9%), RPN (0,3 e 0,27) e FN (15,4 e 23,1%). As médias das glicemias 1hPS foram semelhantes, 106,8 mg/dl para o TTG 50 g e 107,5 mg/dl para o TTG 100 g. CONCLUSÕES: Os resultados da eficiência diagnóstica associados à simplicidade, praticabilidade e custo referendaram a associação GJ + FR como o mais adequado para o rastreamento. A equivalência das glicemias de 1hPS permitiram a proposição de um novo protocolo de rastreamento e diagnóstico do diabete gestacional, com menores custo e desconforto.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present study is aimed to determine serum and urine interleukin-8 (IL-8) levels in premature infants with late onset sepsis (LOS) and to evaluate if urine IL-8 is a useful test for LOS diagnosis. Fifty-six premature infants admitted to the NICU over 1 year had serum and urine IL-8 determined by ELISA. They were divided into three groups: I definite sepsis, II probable sepsis and III non-infected. Results were expressed as mean or median. Differences between groups were assessed by ANOVA, Kruskal-Wallis ANOVA and Dunns Method. Sensitivity, specificity and positive and negative predictive values were calculated and a receiver operator characteristic curve was constructed to determine serum and urine IL-8 accuracy. There were no differences between groups for birth weight, and gestational and post-natal age. Median serum and urine IL-8 levels were significantly higher in GI and GII: 929 x 906 x 625pg/ml; P=0.024, and 249 x 189 x 42pg/mgCr; P< 0.001. Optimal cut-off point was 625pg/ml for serum IL-8 with 69 sensitivity and 75pg/mgCr for urine IL-8 with 92 sensitivity. IL-8 can be determined in urine from premature infants with LOS and is an accurate and feasible diagnosis method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Os objetivos do presente estudo foram avaliar a correlação entre a contagem eletrônica de células somáticas (eCCS) com o Somaticell® sob diferentes níveis de contagem de células somáticas (CCS) do leite e patógenos causadores de mastites, além de calcular a sensibilidade, especificidade e valores preditivos do Somaticell® utilizando diferentes limites de CCS estabelecidos pelos diferentes países. Trezentos e quarenta amostras de leite foram coletadas assepticamente após realização do California Mastitis Test (CMT). O Somaticell® e a eCCS foram realizados em todas as amostras de leite. A correlação entre o Somaticell® e a contagem eletrônica foi determinada de acordo com o CMT, patógeno isolado e escore de eCCS. de acordo com os escores de CCS estabelecidos, 26,5% das amostras de leite apresentaram escore 1 (69-166 x10³células mL-1), 26,8% escore 2 (167-418x10³células mL-1), 27,4% escore 3 (419-760x10³células mL-1) e 19,4% escore 4 (761 to 1970x10³células mL-1). A eCCS e o Somaticell® apresentaram correlação positiva em quase todos os escores estudados (exceto escore 2 e 3). O valor de r obtido entre CCS e o Somaticell® foi de 0,32. Observou-se que, quando o limite de CCS estabelecido aumentou, a sensibilidade decresceu e os valores de especificidade aumentaram. Os valores preditivos apresentaram-se constantes em todos os limites. Quando o limite de CCS era baixo (<760,000 células mL-1), Somaticell® forneceu resultados consistentemente mais elevados que os valores de CCS. Já para amostras com CCS elevada, Somaticell® resultou em menores contagens que a eCCS. A correlação entre os dois métodos permaneceu relativamente constante em todas as condições e os valores de sensibilidade e especificidade do teste são altamente dependentes do limite estabelecido. Os resultados deste trabalho sugerem que o Somaticell® não é útil para avaliar a CCS do leite, pois seus resultados são significativamente diferentes da eCCS, no entanto, pode ser utilizado como método de triagem, tal como o CMT, para a detecção do aumento da CCS do leite.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To compare visual inspection (VI), radiographic examination (RX) and the laser fluorescence device DIAGNOdent (L), as well as their combinations in vitro regarding treatment decisions for occlusal surfaces. Methods: 72 extracted human permanent teeth (molars and premolars) were used. Treatment decisions were recorded by three calibrated examiners, and the options available were fissure sealant and conservative restoration. For validation of treatment decisions, the teeth were sectioned and examined in a stereomicroscope. Thereafter, dental slices were scanned and the images were edited to facilitate classification of existing carious lesions. Intra and inter-examiner reproducibility for the determination of treatment plans were calculated using Cohen's kappa test (95%-CI). Sensitivity, specificity, positive and negative predictive values, and the area under the ROC curve were also calculated. Results: VI and L provided on average the greatest intra- and inter-examiner reproducibility, respectively. Although the combination of diagnostic methods may decrease both intra- and inter examiners reproducibility, combination of VI, L and RX resulted in the greatest sensitivity, being statistically superior to RX and L. There was more inter-examiner agreement for the option of restorative treatment, while the use of sealants as a treatment option yielded the lowest values. Negative predictive values were numerically inferior to positive predictive values, indicating that the examiners preferred not to restore a carious tooth than to proceed operatively in an intact tooth. The combination of the three methods studied showed the best results in determining treatment plans for occlusal surfaces, when compared to the other types of exams. on the other hand, radiographic examination and laser fluorescence were less efficient when used alone.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: comparar medidas de tamanhos dentários, suas reprodutibilidades e a aplicação da equação de regressão de Tanaka e Johnston na predição do tamanho dos caninos e pré-molares em modelos de gesso e digital. MÉTODOS: trinta modelos de gesso foram escaneados para obtenção dos modelos digitais. As medidas do comprimento mesiodistal dos dentes foram obtidas com paquímetro digital nos modelos de gesso e nos modelos digitais utilizando o software O3d (Widialabs). A somatória do tamanho dos incisivos inferiores foi utilizada para obter os valores de predição do tamanho dos pré-molares e caninos utilizando equação de regressão, e esses valores foram comparados ao tamanho real dos dentes. Os dados foram analisados estatisticamente, aplicando-se aos resultados o teste de correlação de Pearson, a fórmula de Dahlberg, o teste t pareado e a análise de variância (p < 0,05). RESULTADOS: excelente concordância intraexaminador foi observada nas medidas realizadas em ambos os modelos. O erro aleatório não esteve presente nas medidas obtidas com paquímetro, e o erro sistemático foi mais frequente no modelo digital. A previsão de espaço obtida pela aplicação da equação de regressão foi maior que a somatória dos pré-molares e caninos presentes nos modelos de gesso e nos modelos digitais. CONCLUSÃO: apesar da boa reprodutibilidade das medidas realizadas em ambos os modelos, a maioria das medidas dos modelos digitais foram superiores às do modelos de gesso. O espaço previsto foi superestimado em ambos os modelos e significativamente maior nos modelos digitais.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective, the objective of this study was to evaluate the reliability of in vivo staining with toluidine blue in the detection of oral epithelial dysplasia, in situ carcinoma, and invasive squamous cell carcinomas in potentially malignant epithelial lesions (PMELs) and superficial oral ulcerations suggesting malignancy.Study design. Fifty patients with PMELs and superficial oral ulcerations suggestive of malignancy were selected from those treated at the Oral Medicine Service, Faculty of Dentistry, Araraquara, Brazil. All lesions were submitted to staining with an aqueous solution of 1% toluidine blue, followed by biopsy and histologic analysis. The sensitivity, specificity, and positive and negative predictive values were calculated.Results. Histologic diagnosis revealed that 14% of the lesions analyzed were in situ carcinoma and invasive squamous cell carcinomas, 12% were epithelial dysplasias, 13% were keratosis, 40% were lichen planus, and 8% were other benign lesions. The sensitivity uf the staining was 77%, the specificity 67%, and the positive and negative predictive values 43.5% and 88.9%, respectivelyConclusions, Staining with toluidine blue was demonstrated to be highly reliable in the detection of in situ carcinoma acid invasive squamous cell carcinoma, because false-negative results for the lesions did not occur. Toluidine blue staining is an adjunct to clinical judgment and not a substitute for either judgment or biopsy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introdução: O exame colpocitológico ou teste de Papanicolaou permite o diagnóstico precoce do câncer de colo do útero. O êxito no rastreamento desta doença dependerá, além de outros fatores, da acuidade diagnóstica do exame colpocitológico. Objetivos: Avaliar a acurácia diagnóstica da citologia cervicovaginal na detecção de lesões cervicais através da comparação citoistopatológica. Material e métodos: Avaliou-se o grau de concordância entre os exames citológico e histopatológico de 373 pacientes atendidas em um hospital universitário no período de 1990 a 1997 e foram calculados os indicadores: sensibilidade, especificidade, valores preditivos positivos e negativos e as taxas de falsos positivos e falsos negativos do exame. Resultados: A taxa bruta de concordância citoistopatológica foi de 65,1%. A sensibilidade do exame foi alta (96,0%), no entanto sua especificidade foi baixa (51,5%), significando a inclusão de muitos resultados falsos positivos. A taxa de falsos positivos foi de 48,4%, enquanto a de falsos negativos foi de 4%. Discussão: Apesar de a sensibilidade do teste ser alta, sua especificidade é baixa, significando que muitas mulheres seriam falsamente diagnosticadas como doentes, levando a um número elevado de resultados falsos positivos e custos desnecessários, além do potencial caráter iatrogênico que esta ação poderia assumir. No entanto, um exame altamente sensível é o teste de escolha para programas de rastreamento de câncer cervical na população feminina. Conclusões: Para garantir a acuidade diagnóstica do teste de Papanicolaou são essenciais atividades de controle de qualidade nos laboratórios, tanto do procedimento colpocitológico quanto do histopatológico, permitindo, assim, o êxito na detecção precoce e no tratamento das lesões cervicais.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Uma prova de imunoadsorção enzimática (ELISA) para detecção de anticorpos contra Babesia bovis foi desenvolvida e avaliada em comparação à imunofluorescência indireta (IFI). A sensibilidade e especificidade do ELISA, determinadas pela análise de 100 soros positivos de bovinos infectados experimentalmente com B. bovis e 108 soros negativos colhidos de bovinos livres de infecção por este hemoparasito, foram de 98,0% e 98,1%, respectivamente. Os valores preditivos positivo e negativo foram, respectivamente, 98,0% e 98,1% e a precisão do teste foi de 98,1%. Não foram detectadas reações cruzadas com 80 soros de bezerros experimentalmente inoculados com Babesia bigemina. O ELISA foi comparado à IFI usando 110 soros de rebanhos de área de estabilidade endêmica e 168 soros de rebanhos de áreas de instabilidade endêmica. em ambos os casos, houve concordância significativa (P=0,631 e 0,4725, respectivamente) entre os resultados demonstrados pelos dois testes. em um estudo epidemiológico realizado com o ELISA na região do Pantanal de Mato Grosso do Sul, com 1.365 soros de bovinos, 83,9% foram positivos para anticorpos contra B. bovis, caracterizando a região estudada como endemicamente estável.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Alterações anatômicas e fisiológicas da gravidez predispõem gestantes a infecções do trato urinário (ITU). O objetivo deste estudo foi identificar a acurácia do exame de urina simples para diagnóstico de ITU em gestantes de baixo risco. Fez-se uso do estudo de desempenho de teste diagnóstico realizado em Botucatu, SP, com 230 gestantes, entre 2006 e 2008. Os resultados mostram que a prevalência de ITU foi de 10%. A sensibilidade foi 95,6%, especificidade 63,3% e acurácia 66,5% do exame de urina simples, em relação ao diagnóstico de ITU. A análise dos valores preditivos positivo e negativo (VPP e VPN) mostrou que, na vigência de exame de urina simples normal, a chance de haver ITU foi pequena (VPN 99,2%). Frente ao resultado alterado desse exame, a probabilidade de haver ITU foi baixa (VPP 22,4%). Conclui-se que a acurácia do exame de urina simples como meio diagnóstico de ITU foi baixa, sendo indispensável a realização de urocultura para o diagnóstico.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

IgG, IgM and IgA antibodies to GP43 (glycoprotein fraction of Paracoccidioides brasiliensis) were measured by ELISA in 63 samples from 23 patients with paracoccidioidomycosis before and twice after chemotherapy was started. Antibodies against P. brasiliensis were detected by indirect immunofluorescence (IF) (IgG, IgM and IgA isotypes), counterimmunoelectrophoresis (CIE) and complement fixation. Two control groups composed of 19 healthy individuals and 12 patients with other diseases (six with histoplasmosis, three with tuberculosis and three with other mycoses). The highest efficiency percentages were found with IgG and IgA- ELISA (100%), IgG-IF (96.2%), CIE (94.4%) and the lowest with CF (75.9%). Highest positive and negative predictive values (100%) were observed for IgG and IgA ELISA. IgG and IgM-ELISA antibodies are more often found in patients with acute than chronic disease (P = 0.01). Four to six months after treatment follow-up showed decreased levels of IgG and IgM-ELISA for acute cases and decreased titres of CIE for chronic cases in relation to pretreatment levels. This study suggests that IgG-ELISA anti-GP43 represents a good marker to monitor clinical response to therapy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Marfan syndrome (MFS) is an autosomal dominant trait due to mutations in the fibrillin gene (FBN1). The MFS expressivity is variable, and its diagnosis relies completely on clinical criteria. Atypical cases and Marfan- like (marfanoid) clinical presentations are commonly found. The metacarpophalangeal pattern profile (MCPP), a radiological method in which the 19 tubular hand bones are assessed, has been used in the diagnosis of various syndromes. To investigate whether the MCPP was adequate to discriminate between MFS and Marfan-like subjects, we studied 38 patients who were referred to our service because they had an MFS diagnosis, diagnostic hypothesis, or differential diagnosis or had arachnodactyly with dolichostenomelia. Two groups were formed: 1) MFS: 21 patients with a mean age of 18.3 (10.8 S.D.) years and 2) Marfan-like syndromes: 16 patients who did not meet the current criteria, with a mean age of 14.6 (4.6 S.D.) years. The MCPP was performed in each case following the classical technique, and a characteristic mean profile was obtained for group I (MFS), with Z scores ranging from 0.69 to 2.73 (1.80 ± 0.50; mean ± S.D.). In group I, three cases had no correlation with the typical MFS pattern. In group II, three cases had an MFS pattern. The correlation with the mean MCPP of MFS permitted the differential diagnosis of MFS and marfanoid syndromes with 86% sensitivity, 81% specificity, and 86% positive and 81% negative predictive values. The results suggest that MCPP can be used effectively as an auxiliary tool in the nosology of these conditions and, because there is no change in MCPP with age, can be helpful in early diagnosis.