Somaticell® as a screening method for somatic cell count from bovine milk


Autoria(s): Langoni, Hélio; Penachio, Daniel da Silva; Nóbrega, Diego Borin; Guimarães, Felipe de Freitas; Lucheis, Simone Baldini
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

20/05/2014

20/05/2014

01/06/2012

Resumo

Os objetivos do presente estudo foram avaliar a correlação entre a contagem eletrônica de células somáticas (eCCS) com o Somaticell® sob diferentes níveis de contagem de células somáticas (CCS) do leite e patógenos causadores de mastites, além de calcular a sensibilidade, especificidade e valores preditivos do Somaticell® utilizando diferentes limites de CCS estabelecidos pelos diferentes países. Trezentos e quarenta amostras de leite foram coletadas assepticamente após realização do California Mastitis Test (CMT). O Somaticell® e a eCCS foram realizados em todas as amostras de leite. A correlação entre o Somaticell® e a contagem eletrônica foi determinada de acordo com o CMT, patógeno isolado e escore de eCCS. de acordo com os escores de CCS estabelecidos, 26,5% das amostras de leite apresentaram escore 1 (69-166 x10³células mL-1), 26,8% escore 2 (167-418x10³células mL-1), 27,4% escore 3 (419-760x10³células mL-1) e 19,4% escore 4 (761 to 1970x10³células mL-1). A eCCS e o Somaticell® apresentaram correlação positiva em quase todos os escores estudados (exceto escore 2 e 3). O valor de r obtido entre CCS e o Somaticell® foi de 0,32. Observou-se que, quando o limite de CCS estabelecido aumentou, a sensibilidade decresceu e os valores de especificidade aumentaram. Os valores preditivos apresentaram-se constantes em todos os limites. Quando o limite de CCS era baixo (<760,000 células mL-1), Somaticell® forneceu resultados consistentemente mais elevados que os valores de CCS. Já para amostras com CCS elevada, Somaticell® resultou em menores contagens que a eCCS. A correlação entre os dois métodos permaneceu relativamente constante em todas as condições e os valores de sensibilidade e especificidade do teste são altamente dependentes do limite estabelecido. Os resultados deste trabalho sugerem que o Somaticell® não é útil para avaliar a CCS do leite, pois seus resultados são significativamente diferentes da eCCS, no entanto, pode ser utilizado como método de triagem, tal como o CMT, para a detecção do aumento da CCS do leite.

The objectives of the present study were to evaluate the correlation between electronic somatic cell count (eSCC) and Somaticell® under different milk somatic cell count (SCC) conditions and to different mastitis pathogens and calculate the, sensitivity, specificity and predictive values of Somaticell® using different SCC limits established by different countries. Three-hundred and forty milk samples were aseptically collected according to the California Mastitis Test (CMT) result. The Somaticell® and eSCC were carried out in all milk samples. The correlation between Somaticell® test results and electronic counts was determined according to the CMT, isolated pathogen and eSCC score. According to the SCC scores established, 26.5% milk samples showed score 1 (69-166x10³cells mL-1), 26.8% score 2 (167-418x10³cells mL-1), 27.4% score 3 (419-760x10³cells mL-1) and 19.4% score 4 (761 to 1,970x10³cells mL-1). According to Spearmann correlation test, eSCC and Somaticell® had a positive correlation (P<0.05) in almost all conditions (except eSCC score 2 and score 3). The r value obtained between the SCC and Somaticell® was 0.32. It was observed that as the SCC thresholds increased, the sensitivity values decrease and specificity increased. The predictive values remained constant among all limits. When the SCC limit is lower (<760,000cells mL-1), Somaticell® resulted in higher counts than the SCC. As for samples with high SCC, Somaticell® resulted in lower counts than the eSCC. The correlation between the two methods remained relatively constant in all conditions and the sensitivity and specificity of the test is highly dependent of the threshold established. The results of this study suggest that Somaticell® is not useful to evaluate milk SCC, as its results are significant different from the eSCC. Therefore it could be used as a screening method, such as CMT, to detect an increase in the milk SCC.

Formato

1095-1101

Identificador

http://dx.doi.org/10.1590/S0103-84782012005000035

Ciência Rural. Universidade Federal de Santa Maria (UFSM), v. 42, n. 6, p. 1095-1101, 2012.

0103-8478

http://hdl.handle.net/11449/13821

10.1590/S0103-84782012005000035

S0103-84782012000600024

WOS:000306227800024

S0103-84782012000600024.pdf

Idioma(s)

eng

Publicador

Universidade Federal de Santa Maria (UFSM)

Relação

Ciência Rural

Direitos

openAccess

Palavras-Chave #avaliação #contagem de células somáticas #Somaticell® #evaluation #somatic cell count #Somaticell®
Tipo

info:eu-repo/semantics/article