61 resultados para Method development and research

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: Darunavir is widely used in HIV/AIDS therapy. It is a HIV protease inhibitor that has excellent efficacy against the virus. The aim of this study is to develop and validate an analytical method fast and free of interferences for determination of darunavir ethanolate as raw material and tablet dosage form. Methodology: As the formulation excipients show high interference in darunavir determination by a direct UV absorption measurement a derivative spectrophotometry was applied. A selective, easy and fast method was achieved employing simple and cheap instrumentation by using first-order derivative spectrophotometry. Results: The first-derivation of spectrum of the drug measured between 200 and 400 nm allowed identification of the analyte and showed absence of placebo interference. The assay was based on the absorbance at 276nm. The linear concentration range was established from 11 to 21 μg/mL. The intra-day and inter-day precision expressed as RSD was 0.06% and 3.75% respectively with mean recovery of 99.84%. Conclusion: The proposed analytical method is able to quantify darunavir as raw material and tablets and can be used routinely by any laboratory applying a spectrophotometer with a derivative accessory. The great difference of the method proposed here is that it proves to be free of placebo interferences as well as simple, fast and low cost.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A gas chromatographic method to determine caprolactam in multilayer PA-6 films used for meat foodstuffs and cheese was developed and validated. A wide linear range (0.8-400 mu g/ml), RSD <= 4.1% and recovery higher than 90.0% were obtained for the chromatographic system, while precision and accuracy of the method showed RSD <= 3.8%, recovery from 95.5-100.0% and LOQ of 32 mu g/g. Irradiated (3, 7 and 12 kGy) and non-irradiated commercial films were analyzed. Most of them increased caprolactam levels with the increase of irradiation doses. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cyclic oligomers were identified in PET bottles used for mineral water and fruit juice using MS and H-1 and C-13 NMR: a first series cyclic trimer, a first series cyclic tetramer, a first series cyclic dimmer and a second series cyclic trimer. An analytical method to determine first series cyclic trimer in these bottles was developed and validated, using HPLC. The first series cyclic trimer levels were 316-462 mg/100 g of PET bottle. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A reversed phase liquid chromatographic method was developed for the simultaneous determination of carboxylic acids and phenolics in white wines. The samples, diluted, were injected onto a Spherisorb ODS-2 column with a gradient of sulfuric acid (pH 2.5)/methanol as mobile phase. A diode array detector was used which was set at 210nm for carboxylic acids and altered to 278nm, during the run, far phenolics and sorbic acid. The identification of compounds was based on retention time, co-chromatography and UV spectrum. Some clean-up methods (sep-pak C-18 and an ion exchange column) mere tested and did not improve the results.The analysis was simple, with no sample preparation. Application of this method was illustrated by analyses of Brazilian Welchriesling wines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, sensitive and accurate spectrophotometric method was developed for the assay of gatifloxacin in raw material and tablets. Validation of the method yielded good results concerning range, linearity, precision and accuracy. The absorbance was measured at 287 nm for gatifloxacin tablet solutions. The linearity range was found to be 4.0-14.0 μg/mL for gatifloxacin. It was also found that the excipients in the commercial tablets did not interfere with the method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, rapid, selective and specific high performance liquid chromatographic (HPLC) method for quantitative analysis of the triamcinolone in polylactide-co-glycolide acid (PLGA) microparticles was developed. The chromatographic parameters were reversed-phase C18 column, 250mm x 4.6mm, with particle size 5 μm. The column oven was thermostated at 35°C ± 2°C. The mobile phase was methanol/water 45:55 (v/v) and elution was isocratic at a flow-rate of 1 mL.mL-1. The determinations were performed using a UV-Vis detector at 239 nm. The injected sample volume was 10 μL. The standard curve was linear (r2 > 0.999) in the concentration range 100-2500 ng.mL-1. The method showed adequate precision, with a relative standard deviation (RSD) was smaller than 3%. The accuracy was analyzed by adding a standard drug and good recovery values were obtained for all drug concentrations used. The method showed specificity and selectivity with linearity in the working range and good precision and accuracy, making it very suitable for quantitation of triamcinolone in PLGA microparticles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lubricating oils are crucial in the operation of automotive engines because they both reduce friction between moving parts and protect against corrosion. However, the performance of lubricant oil may be affected by contaminants, such as gasoline, diesel, ethanol, water and ethylene glycol. Although there are many standard methods and studies related to the quantification of contaminants in lubricant oil, such as gasoline and diesel oil, to the best of our knowledge, no methods have been reported for the quantification of ethanol in used Otto cycle engine lubrication oils. Therefore, this work aimed at the development and validation of a routine method based on partial least-squares multivariate analysis combined with attenuated total reflectance in the mid-infrared region to quantify ethanol content in used lubrication oil. The method was validated based on its figures of merit (using the net analyte signal) as follows: limit of detection (0.049%), limit of quantification (0.16%), accuracy (root mean square error of prediction=0.089% w/w), repeatability (0.05% w/w), fit (R 2 =0.9997), mean selectivity (0.047), sensitivity (0.011), inverse analytical sensitivity (0.016% w/w-1) and signal-to-noise ratio (max: 812.4 and min: 200.9). The results show that the proposed method can be routinely implemented for the quality control of lubricant oils. © 2013 Elsevier B.V. All rights reserved.