Effects of gamma-irradiation on caprolactam level from multilayer PA-6 films for food packaging: Development and validation of a gas chromatographic method
Contribuinte(s) |
Universidade Estadual Paulista (UNESP) |
---|---|
Data(s) |
20/05/2014
20/05/2014
01/07/2008
|
Resumo |
A gas chromatographic method to determine caprolactam in multilayer PA-6 films used for meat foodstuffs and cheese was developed and validated. A wide linear range (0.8-400 mu g/ml), RSD <= 4.1% and recovery higher than 90.0% were obtained for the chromatographic system, while precision and accuracy of the method showed RSD <= 3.8%, recovery from 95.5-100.0% and LOQ of 32 mu g/g. Irradiated (3, 7 and 12 kGy) and non-irradiated commercial films were analyzed. Most of them increased caprolactam levels with the increase of irradiation doses. (C) 2008 Elsevier Ltd. All rights reserved. |
Formato |
913-917 |
Identificador |
http://dx.doi.org/10.1016/j.radphyschem.2008.03.001 Radiation Physics and Chemistry. Oxford: Pergamon-Elsevier B.V. Ltd, v. 77, n. 7, p. 913-917, 2008. 0969-806X http://hdl.handle.net/11449/7171 10.1016/j.radphyschem.2008.03.001 WOS:000257037200011 |
Idioma(s) |
eng |
Publicador |
Pergamon-Elsevier B.V. Ltd |
Relação |
Radiation Physics and Chemistry |
Direitos |
closedAccess |
Palavras-Chave | #gamma-irradiation #caprolactam #food-packaging multilayer films #polyamide 6 #GC #validation |
Tipo |
info:eu-repo/semantics/article |