163 resultados para G METHOD


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We suggest a method for constructing trial eigenfunctions for excited states to be used in the variational method. This method is a generalization of the one that uses a superpotential to obtain the trial functions for the ground state. The construction of an effective hierarchy of Hamiltonians is used to determine excited variational energies. The first four eigenvalues for a quartic double-well potential are calculated for several values of the potential parameter. The results are in very good agreement with the eigenvalues obtained by numerical integration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cell culture of Maytenus ilicifolia were established in order to produce and to quantify the antitumoral and antioxidant quinonemethide triterpenes. In vitro calli were induced from leaf explants of native plants and cultured in semi-solid medium under controlled conditions of humidity, temperature and photoperiod. The quinonemethide triterpenes showed maximum accumulation in the logarithmic phase growth of the cell culture. A rapid, sensitive and reliable reverse-phase HPLC method was used for quantitative determination of the antitumoral and antioxidant quinonemethide triterpenes, 22β-hydroxymaytenin and maytenin in callus of Maytenus ilicifolia. Well resolved peaks with good detection response and linearity in the range 1.0 - 100 μg/mL were obtained. This quantitative work was performed by an external standard method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents an alternative methodology for loading margin improvement and total real power losses reduction by using a continuation method. In order to attain this goal, a parameterizing equation based on the total real power losses and the equations of the reactive power at the slack and generation buses are added to the conventional power flow equations. The voltages at these buses are considered as control variables and a new parameter is chosen to reduce the real power losses in the transmission lines. The results show that this procedure leads to maximum loading point increase and consequently, in static voltage stability margin improvement. Besides, this procedure also takes to a reduction in the operational costs and, simultaneously, to voltage profile improvement. Another important result of this methodology is that the resulting operating points are close to that provided by an optimal power flow program. © 2004 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple, sensitive and accurate spectrophotometric method was developed for the assay of gatifloxacin in raw material and tablets. Validation of the method yielded good results concerning range, linearity, precision and accuracy. The absorbance was measured at 287 nm for gatifloxacin tablet solutions. The linearity range was found to be 4.0-14.0 μg/mL for gatifloxacin. It was also found that the excipients in the commercial tablets did not interfere with the method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple and reproducible method was developed for the assay of lomefloxacin in tablets. The excipients in the commercial tablet preparation did not interfere with the assay. Beer's law is obeyed in the range 2.0-9.0 μg.mL-1 at λmax 280 nm. The molar absorptivity was calculated. Six triplicate analyses of solutions containing six different concentrations of the examined drug were carried out and gave a mean correlation coefficient 0.9997. The proposed method was applied to the determination of the examined drug in coated tablet and the results demonstrated that the method is equally accurate, precise and reproducible as the official methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this paper was to apply a multiresidue method using Supercritical Fluid Extraction (SFE) and capillary gas chromatography with electron capture and mass spectrometry detections in the analysis of the levels of pesticide residues in fruits and vegetables. Single laboratory validation of both solid-liquid and supercritical fluid extraction methods was carried out for 32 compounds selected from four pesticide classes (organochlorine, organonitrogen, organophosphorus and pyretroid) in blank and fortified samples of fresh lettuce, potato, apple and tomato. Recoveries for the majority of pesticides from fortified samples at fortification level of 0.04-0.10 mg kg -1 ranged 74-96% for both methods and confirmation of pesticide identity was performed by gas-chromatography-mass spectrometry in a selected-ion monitoring mode. Both methods showed good limits of detection (less 0.01 mg kg-1, depending on the pesticide and matrix) and the SFE method minimized environmental concerns, time, and laboratory work. ©2005 Sociedade Brasileira de Química.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To enhance the global search ability of Population Based Incremental Learning (PBIL) methods, It Is proposed that multiple probability vectors are to be Included on available PBIL algorithms. As a result, the strategy for updating those probability vectors and the negative learning and mutation operators are redefined as reported. Numerical examples are reported to demonstrate the pros and cons of the newly Implemented algorithm. ©2006 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this prospective study was to determine the DNA fragmentation levels before and after sperm preparation by layering method. A total of 78 patients submitted to assisted reproduction technology (ART) for infertility treatment were evaluated. Ejaculated spermatozoa were obtained by masturbation on the day of ART procedure. The evaluation of DNA fragmentation was performed in the fresh semen and after preparation by a layering method, respectively. After washing with PBS, the sperm pellets were smears and then processed for the terminal deoxyribonucleotidyl transferase (TdT)-mediated dUTP nick-end labelling (TUNEL) assay that was performed using a Cell Death Detection Kit with tetramethylrhodamine-labelled dUTP. For quantitative evaluation, 200 spermatozoa in randomly selected areas on microscope slides were evaluated and the percentage of TUNEL positive spermatozoa was determined. If ≥20% of selected sperm were TUNEL positive, the exam was considered abnormal. The mean percentage of DNA sperm fragmentation before sperm preparation was 17±8.3% and after 7.8±6.5% (p<0.0001). The exam was considered normal in 49 patients before preparation and in 73 patients after (p<0.0001). The sperm preparation with a layering method for the ART procedure is effective to select sperm with a significant decrease of the DNA damage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a new approach to the resolution of the Optimal Power Flow problem. In this approach the inequality constraints are treated by the Modified Barrier and Primal-Dual Logarithmic Barrier methods. The inequality constraints are transformed into equalities by introducing positive auxiliary variables, which are perturbed by the barrier parameter. A Lagrangian function is associated with the modified problem. The first-order necessary conditions are applied to the Lagrangian, generating a nonlinear system which is solved by Newton's method. The perturbation of the auxiliary variables results in an expansion of the feasible set of the original problem, allowing the limits of the inequality constraints to be reached. Numerical tests on the Brazilian CESP and South-Southeast systems and a comparative test indicated that the new approach efficiently resolves of the Optimal Power Flow problem. © 2007 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To ensure high accuracy results from GPS relative positioning, the multipath effects have to be mitigated. Although the careful selection of antenna site and the use of especial antennas and receivers can minimize multipath, it cannot always be eliminated and frequently the residual multipath disturbance remains as the major error in GPS results. The high-frequency multipath from large delays can be attenuated by double difference (DD) denoising methods. But the low-frequency multipath from short delays is very difficult to be reduced or modeled. In this paper, it is proposed a method based on wavelet regression (WR), which can effectively detect and reduce the low-frequency multipath. The wavelet technique is firstly applied to decompose the DD residuals into the low-frequency bias and high-frequency noise components. The extracted bias components by WR are then directly applied to the DD observations to correct them from the trend. The remaining terms, largely characterized by the high-frequency measurement noise, are expected to give the best linear unbiased solutions from a least-squares (LS) adjustment. An experiment was carried out using objects placed close to the receiver antenna to cause, mainly, low-frequency multipath. The data were collected for two days to verify the multipath repeatability. The ground truth coordinates were computed with data collected in the absence of the reflector objects. The coordinates and ambiguity solution were compared with and without the multipath mitigation using WR. After mitigating the multipath, ambiguity resolution became more reliable and the coordinates were more accurate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: The objective of the present study was to evaluate the degree of sedation, intraocular pressure, and hemodynamic changes with premedication with low doses of oral clonidine, 100 μg and 200 μg, in outpatient cataract surgeries. METHODS: This is a randomized, double-blind, clinical study undertaken at the Universidade Federal de São Paulo with 60 patients of both genders, physical status ASA 1 and 2, ages 18 to 80 years. Patients were separated into three groups: placebo, clonidine 100 μg, and clonidine 200 μg. Intraocular pressure, heart rate, and blood pressure besides assessment of sedation were measured before and 90 minutes after the administration of clonidine. Sedation levels were classified according to the Ramsay sedation scale. RESULTS: Patients who received placebo and 100 μg of clonidine did not show reduction in heart rate, while a reduction in heart rate was observed in patients who received 200 μg of clonidine, and this difference was statistically significant. Patients who received 200 μg of clonidine also had a reduction in systolic and diastolic blood pressure (p < 0.05). One patient who received 200 μg of clonidine developed severe hypotension, with systolic pressure < 80 mmHg. Patients treated with clonidine had a reduction in intraocular pressure (p < 0.05). Ninety minutes after the oral administration of placebo and 100 μg and 200 μg of clonidine, 25%, 60%, and 80% of the patients respectively were classified as Ramsay 3 or 4. CONCLUSIONS: Clonidine 100 μg can be indicated as premedication for fasciectomies, being effective in sedation and reduction of intraocular pressure, without adverse effects on blood pressure and heart rate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work reports on the pure lithium tantalate (LiTaO3), europium (III)-doped LiTaO3 and magnesium (II)-europium (III)-doped LiTaO3 preparared by the polymeric precursor method, using four different powered samples of Eu3+ ion concentrations 0.1 to 1at %. Structural and optical properties of powders have been studied. The different possible sites occupied by the rare earth were examined. The phase contents and lattice parameters were studied by the Rietveld method and the structural disorder in the LiTaO3 host caused by Eu3+ ions was analyzed. Results indicated LiTaO3 free of secondary phases at 650°C and the photoluminescence (PL) emission spectra showed the characteristic sharp emission bands given by Eu3+ ions when they are excited at a wavelength of 399 nm. An increase of dopants contents caused a non-homogeneous broadening and showed a slightly larger one when Mg was added. A displacement of the transition 5D0-7F0 to shorter wavelengths as function of Eu3+ concentration was also noticed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents a method to obtain B-scan images based on linear array scanning and 2R-SAFT. Using this technique some advantages are obtained: the ultrasonic system is very simple; it avoids the grating lobes formation, characteristic in conventional SAFT; and subaperture size and focussing lens (to compensate emission-reception) can be adapted dynamically to every image point. The proposed method has been experimentally tested in the inspection of CFRP samples. © 2010 American Institute of Physics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

the aim of this study was to validate the Alternate Current Biosusceptometry (ACB) for monitoring gastric contractions in rats. In vitro data were obtained to establish the relationship between ACB and the strain-gauge (SG) signal amplitude. In vivo experiments were performed on rats with magnetic markers and SGs previously implanted under the gastric serosa. The effects of the prandial state in gastric motility profiles were obtained. The correlation between in vitro signal amplitudes was strong (R = 0.989). The temporal cross-correlation between the ACB and SG signal amplitude was higher in the postprandial than in the fasting state. Irregular signal profiles, low contraction amplitudes, and smaller signal-to-noise ratios explained the poor correlation for fasting-state recordings. The contraction frequencies using ACB were 0.068 ± 0.007 Hz (postprandial) and 0.058 ± 0.007 Hz (fasting) and those using SG were 0.066 ± 0.006 Hz (postprandial) and 0.059 ± 0.008 Hz (fasting) (P < 0.003). When a magnetic tracer was ingested, there was a strong correlation and a small phasedifference between techniques. We conclude that ACB provides an accurate and sensitive technique for studies of GI motility in the rat. © 2010 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple method to determine Cu, Fe, Mn and Zn in single aliquots of medicinal plants by HR-CS FAAS is proposed. The main lines for Cu, Mn and Zn, and the alternate line measured at the wing of the main line for Fe at 248.327 nm allowed calibration within the 0.025 - 2.0 mg L-1 Cu, 1.0 - 20.0 mg L-1 Fe, 0.05 - 2.0 mg L-1 Mn, 0.025 - 0.75 mg L-1 Zn ranges. Nineteen medicinal plants and two certified plant reference materials were analyzed. Results were in agreement at a 95% confidence level (paired t-test) with reference values. Limits of detection were 0.12 μg L-1 Cu, 330 μg L-1 Fe, 1.42 μg L-1 Mn and 8.12 μg L-1 Zn. Relative standard deviations (n=12) were ≤ 3% for all analytes. Recoveries in the 89 - 105% (Cu), 95 - 108% (Fe), 94 - 107% (Mn), and 93 - 110% (Zn) ranges were obtained.