205 resultados para Grey Mold


Relevância:

10.00% 10.00%

Publicador:

Resumo:

There has been a great interest for improving the machining of cast iron materials in the automotive and other industries. Comparative studies for tool used to machine grey cast iron (CI) and compacted graphite iron (CGI) on dry machining were also performed in order to find out why in this case the tool lifetime is not significantly higher. However the machining these materials while considering turning with the traditional high-speed steel and carbide cutting tools present any disadvantages. One of these disadvantages is that all the traditional machining processes involve the cooling fluid to remove the heat generated on workpiece due to friction during cutting. This paper present a new generation of ceramic cutting tool exhibiting improved properties and important advances in machining CI and CGI. The tool performance was analyzed in function of flank wear, temperature and roughness, while can be observed that main effects were found for tool wear, were abrasion to CI and inter-diffusion of constituting elements between tool and CGI, causing crater. However the difference in tool lifetime can be explained by the formation of a MnS layer on the tool surface in the case of grey CI. This layer is missing in the case of CGI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: The present randomized, controlled prospective study evaluated the histomorphological response of human dental pulps capped with two grey mineral trioxide aggregate (MTA) compounds. Methodology: Pulp exposures were performed on the occlusal floor of 40 human permanent pre-molars. The pulp was capped either with ProRoot (Dentsply) or MTA-Angelus (Angelus) and restored with zinc oxide eugenol cement. After 30 and 60 days, teeth were extracted and processed for histological examination and the effects on the pulp were scored. The data were subjected to Kruskal-Wallis and Conover tests (α = 0.05). Results: In five out of the 40 teeth bacteria were present in pulp tissue. No significant difference was observed between the two materials (P > 0.05) in terms of overall histological features (hard tissue bridge, inflammatory response, giant cells and particles of capping materials). Overall, 94% and 88% of the specimens capped with MTA-Angelus and ProRoot, respectively, showed either total or partial hard tissue bridge formation (P > 0.05). Conclusions: Both commercial materials ProRoot (Dentsply) and MTA-Angelus (Angelus) produced similar responses in the pulp when used for pulp capping in intact, caries-free teeth. © 2009 International Endodontic Journal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Marantaceae leaves have a contrasting color pattern and a decorative design which are interesting traits for its use as cut foliage. No postharvest research has been carried out on the potential as cut foliage for species of Ctenanthe, a member of the Marantaceae. Grey-maranta (Ctenathe setosa) is an herbaceous ornamental plant native of Brazil whose cut foliage has potential to be used as new crop product for local and international ornamental markets. The objective of this study was to evaluate pulse treatments to extend the longevity of foliage. The experiment was conducted in a complete randomized design with three replications and eight treatments: distilled water; pulsing cut petioles-ends in citric acid (pH = 2.8/1h); 2% sucrose (4h); 1% sucrose plus 200 mg L-1 citric acid (4h); 0.01% Tween® 20 (4h); 100 mg L -1 benzyladenine plus 0.01% Tween® 20 (4h); 100 mg L-1 gibberellic acid plus 0.01% Tween® 20 (4h); and maintenance of cut petiole in holding solution with commercial sodium hypochlorite (0.5 mL L-1). The senescence symptoms were mainly characterized by leaf rolling and by a decrease in the angle formed between leaf and petiole as a response to water deficit stress. Gibberellic acid or benzyladenine pulse treatments significantly extended longevity (6 days compared to control) and maintained leaves' green coloration and brightness for a longer time compared to control. However, only the benzyladenine plus Tween® 20 pulse maintained leaves in an erect form for a longer time, showing a significantly higher angle between leaf and petiole compared to control. Also, foliage pulsed with benzyladenine plus Tween® 20 showed a significant smallest loss of accumulated fresh mass percentage compared to control by the T test as to parallelism of treatments lines.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The indirect adhesive procedures constitute recently a substantial portion of contemporary esthetic restorative treatments. The resin cements have been used to bond tooth substrate and restorative materials. Due to recently introduction of the self-bonding resin luting cement based on a new monomer, filler and initiation technology has become important to study the degree of conversion of these new materials. In the present work the polymerization reaction and the filler content of dual-cured dental resin cements were studied by means of infra-red spectroscopy (FT-IR) and thermogravimetry (TG). Twenty specimens were made in a metallic mold (8 mm diameter × 1 mm thick) from each of 2 cements, Panavia® F2.0 (Kuraray) and RelyX™ Unicem Applicap (3M/ESPE). Each specimen was cured with blue LED with power density of 500 mW/cm 2 for 30 s. Immediately after curing, 24 and 48 h, and 7 days DC was determined. For each time interval 5 specimens were pulverized, pressed with KBr and analyzed with FT-IR. The TG measurements were performed in Netzsch TG 209 under oxygen atmosphere and heating rate of 10°C/min from 25 to 700°C. A two-way ANOVA showed DC (%) mean values statistically significance differences between two cements (p < 0.05). The Tukey's test showed no significant difference only for the 24 and 48 h after light irradiation for both resin cements (p > 0.05). The Relx-Y™ Unicem mean values were significantly higher than Panavia® F 2.0. The degree of conversion means values increasing with the storage time and the filler content showed similar for both resin cements. © 2009 Pleiades Publishing, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this paper is to introduce a new approach for edge detection in grey shaded images. The proposed approach is based on the fuzzy number theory. The idea is to deal with the uncertainties concerning the grey shades making up the image and, thus, calculate the appropriateness of the pixels in relation to a homogeneous region around them. The pixels not belonging to the region are then classified as border pixels. The results have shown that the technique is simple, computationally efficient and with good results when compared with both the traditional border detectors and the fuzzy edge detectors. Copyright © 2009, Inderscience Publishers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study is to evaluate the flexural resistance of three types of restorative materials: compomer (Freedom), resin-modified glass-ionomer (Vitremer) and composite resin (Esthet-X), observing whether the application of bleaching agent can cause alterations of their flexural properties. Sixty samples were made using a 10 x 1 x 1 mm brass mold, and divided into three groups: G1- Freedom (SDI); G2- Vitremer (3M ESPE); G3- Esthet-X (Dentsply). On half of the samples of each group (10 samples) the bleaching treatment was applied and the other half used as control, was stored in distilled water at a temperature of 37 degrees C. Whiteness HP Maxx bleaching system was applied on the sample surface following the manufacturer's recommendations, simulating the bleaching treatment at the clinic. After this period, a flexural strength (three-point bending) test was conducted using (EMIC DL 1000) machine until the samples fractured. The data were submitted to ANOVA and Tukey tests. Of the restorative materials studied, G3-(87.24 +/- 31.40 MPa) presented the highest flexural strength, followed by G1-(61.67 +/- 21.32 MPa) and G2-(61.67 +/- 21.32 MPa). There was a statistical difference in flexural strength after the bleaching treatment. It was concluded that the use of a beaching agent can promote significant alteration of the flexural strength of these restorative materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the Knoop hardness of a dual-cured resin cement (Rely-X ARC) activated solely by chemical reaction (control group) or by chemical / physical mode, light-cured through a 1.5 mm thick ceramic (HeraCeram) or composite (Artglass) disc. Light curing was carried out using conventional halogen light (XL2500) for 40 s (QTH); light emitting diodes (Ultrablue Is) for 40 s (LED); and Xenon plasma arc (Apollo 95E) for 3 s (PAC). Bovine incisors had their buccal face flattened and hybridized. On this surface a rubber mold (5 mm in diameter and 1 mm in height) was bulk filled with the resin cement. A polyester strip was seated for direct light curing or through the discs of veneering materials. After dry storage in the dark (24 h 37°C), the samples (n = 5) were sectioned for hardness (KHN) measurements, taken in a microhardness tester (50 gF load 15 s). The data were statistically analyzed by ANOVA and Tukey's test (α = 0.05). The cement presented higher Knoop hardness values with Artglass for QTH and LED, compared to HeraCeram. The control group and the PAC/Artglass group showed lower hardness values compared to the groups light-cured with QTH and LED. PAC/HeraCeram resulted in the worst combination for cement hardness values. © 2009 Sociedade Brasileira de Pesquisa Odontológica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Geological, petrographical, chemicals and technological studies of rocks of the southwest region of Mato Grosso State, Brazil have the purpose of qualification and application of these rocks as dimension stones. The first objective is to enlarge the offering of new esthetic varieties that show a standardization of technologic patterns, adequate characterization and classification assuring the correct specification of the rocks in relation to the use as dimension stones. Ten rock types are recognized for dimension stones, including granites, diabases, gneisses and amphibolites grouped by its colors in red, grey and black types and showing economic potential of plowing. The results obtained in the technological essays show that the rock parameters are sited inside the standard limits established by technical rules and obey satisfactorily the limit values fixed for granites in internal and external covering uses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effect of pre-heating resin composite photo-cured with light-curing units (LCU) by FT-IR. Twenty specimens were made in a metallic mold (4 mm diameter × 2 mm thick) from composite resin-Tetric Ceram® (Ivoclar/Vivadent) at room temperature (25°C) and pre-heated to 37, 54, and 60°C. The specimens were cured with halogen curing light (QTH) and light emitted by diodes (LED) during 40 s. Then, the specimens were pulverized, pressed with KBr and analyzed with FT-IR. The data were submitted to statistical analysis of variance and Kruskal-Wallis test. Study data showed no statistically significant difference to the degree of conversion for the different light curing units (QTH and LED) (p > 0.05). With the increase of temperature there was significant increase in the degree of conversion (p < 0.05). In this study were not found evidence that the light curing unit and temperature influenced the degree of conversion. © 2010 Pleiades Publishing, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the effect of different light energy densities on conversion degree (CD) and Knoop hardness number (KHN) of RelyX ARC (RLX) resin cement. After manipulation according to the manufacturer's instructions, RLX was inserted into a rubber mold (0.8 mm X 5 mm) and covered with a Mylar strip. The tip of the lightcuring unit (LCU) was positioned in contact with the Mylar surface. Quartz-tungsten-halogen (QTH) and light-emitting diode (LED) LCUs with light densities of 10, 20 and 30 J/cm2 were used to light-cure the specimens. After light curing, the specimens were stored dry in lightproof containers at 37°C. After 24 hours, the CD was analyzed by FT-Raman and, after an additional 24-hours, samples were submitted to Knoop hardness testing. The data of the CD (%) and KHN were submitted to two-way ANOVA and the Tukey's test (α=0.05). QTH and LED were effective light curing units. For QTH, there were no differences among the light energy densities for CD or KHN. For LED, there was a significant reduction in CD with the light energy density set at 10 J/cm2. KHN was not influenced by the lightcuring unit and by its light energy density. © Operative Dentistry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this research was to evaluate the white mold severity (Sclerotinia sclerotiorum (Lib.) of Bary), bean production components and yield (Phaseolus vulgaris L.), variety Perola, according to the application of procimidone fungicide (Sialex 500), through fungigation (center pivot) and automotive sprayer (Uniport). The study was carried under field production commercial conditions, in Primavera do Leste - MT - Brazil. The experiment consisted of 5 treatments (with 4 repetitions of 4 ha each), all with two procimidone applications (1.2 kg ha-1 each application, same as, 0.6 kg a.i. per hectare) to the 42 and 52 days after seeding. The water depths of 5.5 and 11.0 mm were tested in the application through central pivot (this had your checked uniformity), providing volumes of 55.000 and 110.000 L ha-1, respectively, and the volumes of 120 and 200 L ha-1 in the automotive sprayer. The severity of disease was evaluated by the percentage of the area affected by plant damage using diagramatic grade scale of white mold severity, as described by Azevedo (1998). The values were used to calculate the area under the disease progress curve (AUDPC). They were also analyzed, the number of the fungus apothecia during the crop cycle and the residual sclerotias weight in harvest. On this occasion, it was also evaluated the crop yield parameters: number of plants per plot (final stand), pods per plant, grains per pod, medium weight of 200 grains and productivity of grains. The AUDPC values, apothecia to 42, 49 and 56 days after seeding, sclerotias in 2 soil kg and the crop productivity parameters were submitted to the variance analysis and Tukey Test at 0.05 of probability. This test was also applied in the comparison among the different fungicide application methods, independent of spray volumes in each one. The statistical processing was accomplished by STAT program. The results showed that weren't differences among application techniques studied in relation to productivity parameters, however, best white mold control, smaller apothecia number to 49 and 56 days after seeding and smaller weight of residual sclerotias in the harvest were obtained with the fungigation, independently of the spray volume used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During a recent inspection in the Paleontological Collection of the Institute of Geosciences, University of São Paulo, we have identifi ed some specimens of undescribed mollusk bivalves. These called our attention for the following reasons: a) all specimens are internal molds of conjugated and closed articulated valves, some of them presenting fragments of silicifi ed shells; b) all internal molds have similar general shape and internal characters, representing specimens of the same taxon; c) the internal molds and silicifi ed valves are well preserved, including fragile structures, which are hardly preserved, such as the internal mold of the external ligament and muscle scars; d) and equally important, according to the labels of all specimens, they were collected from rocks of the Passa Dois Group (Permian), Serrinha Member of the Rio do Rasto Formation. Although who collected the shells and the precise geographic location of the specimens are still unknown, the detailed study of these fossils brings us to the conclusion that they are morphologically distinct from any heretofore published genus of the endemic fauna of bivalves from Passa Dois Group. Based in its general shape, hinge structure and muscles scars, the new form can be classifi ed under the Family Megadesmidae Vokes, 1967, the most diverse group of Permian bivalves of the Paraná Basin. The specimens are referred as Beurlenella elongatella new gen. and sp. The shell shape and taphonomy indicate that this bivalve was a shallow, rapid, active burrower, suspension feeder, probably preserved in situ, in event deposits.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study compared the bond strength durability of a feldspathic veneering ceramic to glass-infiltrated reinforced ceramics in dry and aged conditions. Disc shaped (thickness: 4 mm, diameter: 4 mm) of glass-infiltrated alumina (In-Ceram Alumina) and glass-infiltrated alumina reinforced by zirconia (In-Ceram Zirconia) core ceramic specimens (N=48, N=12 per groups) were constructed according to the manufacturers' recommendations. Veneering ceramic (VITA VM7) was fired onto the core ceramics using a mold. The core-veneering ceramic assemblies were randomly divided into two conditions and tested either immediately after specimen preparation (Dry) or following 30000 thermocycling (5-55 oC±1; dwell time: 30 seconds). Shear bond strength test was performed in a universal testing machine (cross-head speed: 1 mm/min). Failure modes were analyzed using optical microscope (x20). The bond strength data (MPa) were analyzed using ANOVA (α=0.05). Thermocycling did not decrease the bond strength results for both In-Ceram Alumina (30.6±8.2 MPa; P=0.2053) and In-Ceram zirconia (32.6±9 MPa; P=0.3987) core ceramic-feldspathic veneering ceramic combinations when compared to non-aged conditions (28.1±6.4 MPa, 29.7±7.3 MPa, respectively). There were also no significant differences between adhesion of the veneering ceramic to either In-Ceram Alumina or In-Ceram Zirconia ceramics (P=0.3289). Failure types were predominantly a mixture of adhesive failure between the veneering and the core ceramic together with cohesive fracture of the veneering ceramic. Long-term thermocycling aging conditions did not impair the adhesion of the veneering ceramic to the glass-infiltrated alumina core ceramics tested.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We evaluated the effects of disinfection and aging on the hardness of silicones containing opacifiers and intended for use in facial prosthetics. A total of 90 samples were produced using a cylindrical metal mold 3 mm in height and 30 mm in diameter. The samples were fabricated from Silastic MDX 4-4210 silicone in three groups: GI contained no opacifier, GII contained barium sulfate (Ba), and GIII contained titanium dioxide (Ti). The samples were disinfected using effervescent tablets (Ef), neutral soap (Ns), or 4% chlorhexidine (Cl) 3 times a week for 60 days. After this period the samples underwent 1,008 hours of accelerated aging. The hardness was measured using a durometer immediately following the disinfection period and after 252, 504, and 1,008 hours of aging. The data were statistically analyzed using 3-way ANOVA and the Tukey test (p < .05). The GIII group exhibited the greatest variation in hardness regardless of elapsed time. All groups displayed greater hardness after 1,008 hours of accelerated aging independent of disinfectant type. All of the hardness values were within the clinically acceptable range.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the Knoop hardness and polymerization depth of a dual-cured resin cement, light-activated at different distances through different thicknesses of composite resin. One bovine incisor was embedded in resin and its buccal surface was flattened. Dentin was covered with PVC film where a mold (0.8-mm-thick and 5 mm diameter) was filled with cement and covered with another PVC film. Light curing (40 s) was carried out through resin discs (2, 3, 4 or 5 mm) with a halogen light positioned 0, 1, 2 or 3 mm from the resin surface. After storage, specimens were sectioned for hardness measurements (top, center, and bottom). Data were subjected to split-plot ANOVA and Tukey's test (α=0.05). The increase in resin disc thickness decreased cement hardness. The increase in the distance of the light curing tip decreased hardness at the top region. Specimens showed the lowest hardness values at the bottom, and the highest at the center. Resin cement hardness was influenced by the thickness of the indirect restoration and by the distance between the light-curing unit tip and the resin cement surface.