156 resultados para FIA amperometric


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A sensor based on graphite electrode modified with palladium-platinum-palladium film is proposed for phosphite determination by flow-injection amperometry. The modified electrode was prepared by a sequential cathodic deposition of Pd, Pt and Pd on a graphite electrode from 0.5% m/v PdCl2 + 28% m/v NH4OH and 2% m/v H2PtCl6 + 10% v/v H2SO4 solutions. After suitable conditioning, the electrode showed catalytic activity for phosphite oxidation when 0. 15 V was applied. The proposed system handles approximately 50 samples per hour (0.0.1 - 0.05 mol L-1 Na-2 HPO3; R-2 = 0.9997), consuming ca. 70 mu L of sample per determination. The limit of detection and amperometric sensibility were 5 X 10(-4) mol L-1 and 1.5 mA L mol(-1), respectively. The proposed method was applied to analysis of fertilizer samples without pre-treatment. Results are in agreement with those obtained by spectrophotometry and titrimetry at 95% confidence level and good recoveries (96-109%) of spiked samples were found. Relative standard deviation (n=12) of a 0.01 mol L-1 Na2HPO3 sample was 2%. The useful lifetime of modified electrode was around 220 determinations. For routine purposes it means that this electrode can be continuously used for 5 hours.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An amperometric biosensor based on cholinesterase (ChE) has been used for the determination of selected carbamate insecticides in vegetable samples. The linear range of the biosensor for the N-methylcarbamates (aldicarb, carbaryl, carbofuran, methomyl and propoxur) varied from 5 x 10(-5) to 50 mg kg(-1). Limits of detection were calculated on the basis that the ChE enzymes were 10% inhibited and varied, depending of the combination ChE (as acetyl- or butyrylcholinesterase) vs. inhibitor (pesticide), from 1 x 10(-4) to 3.5 mg kg(-1). The biosensor-based carbamate determination was compared to liquid chromatography/UV methods. Three vegetable samples were spiked with carbofuran and propoxur at 125 mu g kg(-1) followed by conventional procedures. Good correlations were observed for carbofuran in the vegetable extracts (79, 96 and 91% recoveries for potato, carrot and sweet pepper, respectively), whereas for propoxur unsatisfactory results were obtained. Potato and carrot samples were spiked with 10, 50 and 125 mu g kg(-1) carbofuran, followed by direct determination by the amperometric biosensor. The fortified sampler; resulted in very high inhibition values, and recoveries were: 28, 34 and 99% for potato, and 140, 90 and 101% for carrot, respectively, at these three fortification levels. (C) 1998 Elsevier B.V. B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Pt-Ir microelectrode modified through one step, electropolymerization is proposed for the isocitrate amperometric biosensor construction. The enzyme (isocitrate dehydrogenase-ICDH), coenzyme (NADP(+)) and mediator (Meldola's Blue) were immobilized onto the microelectrode surface in one step from a PIPES buffer solution containing pyrrole. The optimized experimental conditions were 25 cycles of cyclic voltammetric in a solution containing 3.58 10(-5) mol l(-1) of mediator, 3.51 10(-4) mol l(-1) of coenzyme and 2.68 U ml(-1) of enzyme. In contrast to the biosensor for isocitrate reported in literature, just one enzyme was immobilized and no coenzyme addition in the solution of analysis was necessary. Catalytic currents were proportional to the isocitrate concentration between 7.7 10(-6) and 1.04 10(-4) mol l(-1), showing good repeatability. The detection limit of the proposed biosensor was 3.50 10(-6) mol l(-1), the response time was lower than 20 s, the lifetime was about 30 determinations and no significant interference of sugars and citric acid was verified. Orange juice samples were analysed by both methodology biosensor and spectrophotometric commercial kit, and the obtained results presented a good correlation. The data demonstrated that the developed biosensor is suitable for isocitrate determination in orange juice without matrix interferences. (C) 2001 Elsevier B.V. B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The construction of a flow-through cell incorporating an array of gold microelectrodes is described and its application to flow injection analysis with amperometric detection is presented, Simple modification of almost any conventional integrated circuit chip, used as an inexpensive source of pre-assembled gold micro-wires, leads to the rapid and successful preparation of arrays of 8-48 elements, the polymeric encapsulation material from the top face of the chip is removed by abrasion until the gold micro-mires (used to interconnect the silicon circuit to the external contact pins of the chip) are disrupted and their transversal (elliptical) sections become exposed. Once polished, the flat and smooth top surface of the gold microelectrode-array chip (MEAC) is provided with a spacer and fitted under pressure against an acrylic block with the reference and auxiliary electrodes, to form the electrochemical (thin-layer) flow cell, while the contact pins are plugged into a standard IC socket, This design ensures autonomous electric contact with each electrode and allows fast dismantling for polishing or substitution, the performance of flow cells with MEACs was investigated utilizing the technique of reverse pulse amperometry without oxygen removal, A method was established for the determination of the copper concentration in sugar cane spirit, regulated by law for beverages, Samples from industrial producers and small-scale (alembic) brewers were compared, With a 24 MEAC, a detection limit of 30 mu g I-l of copper (4.7 x 10(-7) mol l(-1) of Cu-II for 100 mu l injections) was calculated, Routine operation was established at a frequency of 60-90 determinations per hour, Intercomparison with atomic absorption spectrometric determinations resulted in excellent agreement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The evolution of elemental Hg from its environmental compounds has already been supposed to be an important process within the global mercury cycle. The present study characterizes the abiotic reduction of Hg(II) ions by typical river humic substances (HS) conventionally pre-isolated by the adsorbent XAD 8 from the Rio Negro near Manaus, Brazil. For the investigation of this reduction process a special reaction and Hg(0) trapping unit combined with cold-vapor atomic absorption spectrometry (CVAAS) was developed. Preconcentration of traces of mercury(II), if required, was obtained by a home-made FIA system using microcolumns filled with the Hg(II)-selective collector CheliteS(R) (Serva Company). The effect of environmentally relevant parameters such as the pH value, the Hg(II)/HS ratio and the HS concentration on the I-IE;(II) reduction process was studied as a function of the time. The Hg(0) production was highest at pH 8.0 and in the case of decreasing HS amounts (0.5 mg) when about 65% of initially 1.0 mug Hg(H) was reduced within 50 h. Moreover, the reduction efficiency of HS towards HE;(II) strongly depended on the HS concentration but hardly on the Hg(II)/HS ratio. The reduction kinetics followed a relatively slow two-step first-order mechanism with formal rate constants of about 0.1 and 0.02 h(-1), respectively. Based on these findings the possible relevance of the abiotic evolution of mercury in humic-rich aquatic environments is considered. (C) 2000 Elsevier B.V. B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes the construction and application of two amperometric sensors for sensitive UV-filter determination. The sensors were prepared using stainless steel electrodes in which polyaniline (PANI) was electrochemically polymerized in the presence of nickel (NiPcTS) or iron (FePcTS) tetrasulfonated phthalocyanines. The sensor surface characterizations were carried out using atomic force microscopy (AFM). The PANI/NiPcTS sensor was selective for the chemical UV-filter p-aminobenzoic acid (PABA) and the PANI/FePcTS sensor was selective for octyldimethyl-PABA (ODP), both in a mixture of tetrahydrofuran (THF) and 0.1 mol L(-1) H(2)SO(4) at a volume ratio of 30 : 70, and with an applied potential of 0.0 mV vs. Ag vertical bar AgCl. A detailed investigation of the selectivity was carried out for both sensors, in order to determine their responses for ten different UV filters. Finally, each sensor was successfully applied to PABA or ODP quantification in sunscreen formulations and water from swimming pools.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow injection analysis (FIA) procedure for the speciation of Cr(III) and Cr(VI) using the 1,5-diphenylcarbazide (DPC) method is presented. As Cr(III) does not interfere in the Cr(VI) - DPC reaction, both Cr(VI) and total chromium [after the on-line oxidation of Cr(III) by Ce(IV)] are sequentially determined. Cr(III) is obtained by difference. Under the experimental conditions described, the calibration graphs are linear up to 2 μg mh1 of Cr(VI) and 4 μg ml-1 of Cr(III). The detection limits found were 18 ng ml -1 for Cr(VI) and 55 ng ml-1 for Cr(III), at a signal to noise ratio of 3. The common interfering elements in the Cr(VI) - DPC reaction were investigated under dynamic FIA conditions. The FIA method was also compared with the conventional spectrophotometric procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to propose a flow spectrophotometric procedure for manganese determination in steel based on electrochemical oxidation of Mn(II) to Mn(VII) at a Pt electrode surface by means of the catalytic effect of Ag(I). The on-line oxidation step was obtained by injecting sample and electrolyte solution directly into an electrolytic cell. After electrolysis, the injectate was homogenized by bubbling air. The permanganate ions produced were passed through the spectrophotometer where absorbance was monitored at 545 nm. Effects of direct current, silver concentration, timing, flow rates, concentration and composition of support electrolyte were investigated. Direct current and silver content manifested themselves as the most relevant parameters. For determination of manganese in the 5.00 - 150 mg L -1 range (r=0,9998) and 60 s electrolysis time, the sample throughput was 20 h -1. Accuracy was assessed by analyzing ten steel standard reference materials. Results are precise (R.S.D. <3%) and in agreement with certified values of reference materials and with standard methods at 95% confidence level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow-injection system with a Chelite-S® cationic resin packed minicolumn is proposed for the determination of trace levels of mercury in agroindustrial samples by cold vapor atomic absorption spectrometry. Improved sensitivity and selectivity are attained since mercuric ions are on-line concentrated whereas other potential interferents are discarded. With on-line reductive elution procedure, concentrated hydrochloric acid could be replaced by 10% w/v SnCl2, in 6 M HCl as eluent. The reversed-intermittent stream either carries the atomic mercury, to the flow cell in the forward direction or removes the residue from reactor/gas liquid separator to a discarding flask in the opposite direction. Concentration and volume of reagent, acidity, flow rates, commutation times and potential interfering species were investigated. For 120 s preconcentration time, the proposed system handles about 25 samples h-1 (50.0 500 ng l-1), consuming about 10 ml sample and 5 mg SnCl2 per determination. The detection limit is 0.8 ng l-1 and the relative standard deviation (RSD) (n = 12) of a 76.7 ng l-1 sample is about 5%. Results are in agreement with certified value of standard materials at 95% confidence level and good recoveries (97-128%) of spiked samples were found. (C) 2000 Elsevier Science B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Improvement of the operational stability of amperometric sensors based on Prussian Blue (PB) modified glassy carbon electrodes is presented. The long term performance of the sensors was evaluated by injection of hydrogen peroxide (5 μM in potassium buffer) solutions in a flow-injection system during a period of 5-10 h. The following parameters were investigated and correlated with the performance of the sensor: the times for electrodeposition and electrochemical activation, temperature, storage time, pH, composition of the buffer solution and of volume sample injected. These analytical characteristics of the modified electrode can be emphasized: initial sensitivity of 0.3 A cm-2 M-1, detection limit of ca. 0.5 μM, precise results (r.s.d.< 1.5%) and possibility to carry out around 50 samples (50 μL) per hour.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chemically modified electrodes based on hexacyanometalate films are presented as a tool in analytical chemistry. Use of amperometric sensors and/or biosensors based on the metal-hexacyanoferrate films is a tendency. This article reviews some applications of these films for analytical determination of both inorganic (e.g. As3+, S2O3 2-) and organic (e.g. cysteine, hydrazine, ascorbic acid, gluthatione, glucose, etc.) compounds.